Intraoperative imaging and navigation of the petrous apex by infralabyrinthine route
Copyright © 2023. Published by Elsevier Masson SAS..
Intraoperative imaging during skull-base surgery allows the operator to control surgical dissection and to tailor the approach, reducing morbidity due to inadequate resection or reintervention. The O-arm® (Medtronic, Fridley, MN, USA) navigation system is an intraoperative cone-beam CT device that was first designed for spinal surgery but now has applications in lateral skull-base surgery. In this technical note, we present a patient with petrous apex cholesterol granuloma located medial to the intrapetrous internal carotid artery and in the infralabyrinthine compartment. We report the possibility of natural drainage, using intraoperative imaging to guide resection, through a rapid, safe and minimally invasive approach.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - year:2024 |
---|---|
Enthalten in: |
European annals of otorhinolaryngology, head and neck diseases - (2024) vom: 16. Jan. |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Schein, A [VerfasserIn] |
---|
Links: |
---|
Themen: |
Cholesterol granuloma |
---|
Anmerkungen: |
Date Revised 17.01.2024 published: Print-Electronic Citation Status Publisher |
---|
doi: |
10.1016/j.anorl.2023.12.002 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM367238098 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM367238098 | ||
003 | DE-627 | ||
005 | 20240118232210.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240118s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.anorl.2023.12.002 |2 doi | |
028 | 5 | 2 | |a pubmed24n1263.xml |
035 | |a (DE-627)NLM367238098 | ||
035 | |a (NLM)38233298 | ||
035 | |a (PII)S1879-7296(23)00169-2 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Schein, A |e verfasserin |4 aut | |
245 | 1 | 0 | |a Intraoperative imaging and navigation of the petrous apex by infralabyrinthine route |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 17.01.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status Publisher | ||
520 | |a Copyright © 2023. Published by Elsevier Masson SAS. | ||
520 | |a Intraoperative imaging during skull-base surgery allows the operator to control surgical dissection and to tailor the approach, reducing morbidity due to inadequate resection or reintervention. The O-arm® (Medtronic, Fridley, MN, USA) navigation system is an intraoperative cone-beam CT device that was first designed for spinal surgery but now has applications in lateral skull-base surgery. In this technical note, we present a patient with petrous apex cholesterol granuloma located medial to the intrapetrous internal carotid artery and in the infralabyrinthine compartment. We report the possibility of natural drainage, using intraoperative imaging to guide resection, through a rapid, safe and minimally invasive approach | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Cholesterol granuloma | |
650 | 4 | |a Computer-assisted surgery | |
650 | 4 | |a Petrous apex | |
700 | 1 | |a Guigou, C |e verfasserin |4 aut | |
700 | 1 | |a Madkouri, R |e verfasserin |4 aut | |
700 | 1 | |a Bozorg Grayeli, A |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t European annals of otorhinolaryngology, head and neck diseases |d 2010 |g (2024) vom: 16. Jan. |w (DE-627)NLM201398648 |x 1879-730X |7 nnns |
773 | 1 | 8 | |g year:2024 |g day:16 |g month:01 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.anorl.2023.12.002 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |j 2024 |b 16 |c 01 |