Implementation of an Institution-Wide Rules-Based Automated CT Protocoling System

BACKGROUND. Examination protocoling is a noninterpretive task that increases radiologists' workload and can cause workflow inefficiencies. OBJECTIVE. The purpose of this study was to evaluate effects of an automated CT protocoling system on examination process times and protocol error rates. METHODS. This retrospective study included 317,597 CT examinations (mean age, 61.8 ± 18.1 [SD] years; male, 161,125; female, 156,447; unspecified sex, 25) from July 2020 to June 2022. A rules-based automated protocoling system was implemented institution-wide; the system evaluated all CT orders in the EHR and assigned a protocol or directed the order for manual radiologist protocoling. The study period comprised pilot (July 2020 to December 2020), implementation (January 2021 to December 2021), and postimplementation (January 2022 to June 2022) phases. Proportions of automatically protocoled examinations were summarized. Process times were recorded. Protocol error rates were assessed by counts of quality improvement (QI) reports and examination recalls and comparison with retrospectively assigned protocols in 450 randomly selected examinations. RESULTS. Frequency of automatic protocoling was 19,366/70,780 (27.4%), 68,875/163,068 (42.2%), and 54,045/83,749 (64.5%) in pilot, implementation, and postimplementation phases, respectively (p < .001). Mean [± SD] times from order entry to protocol assignment for automatically and manually protocoled examinations for emergency department examinations were 0.2 ± 18.2 and 2.1 ± 69.7 hours, respectively; mean inpatient examination times were 0.5 ± 50.0 and 3.5 ± 105.5 hours; and mean outpatient examination times were 361.7 ± 1165.5 and 1289.9 ± 2050.9 hours (all p < .001). Mean [± SD] times from order entry to examination completion for automatically and manually protocoled examinations for emergency department examinations were 2.6 ± 38.6 and 4.2 ± 73.0 hours, respectively (p < .001); for inpatient examinations were 6.3 ± 74.6 and 8.7 ± 109.3 hours (p = .001); and for outpatient examinations were 1367.2 ± 1795.8 and 1471.8 ± 2118.3 hours (p < .001). In the three phases, there were three, 19, and 25 QI reports and zero, one, and three recalls, respectively, for automatically protocoled examinations, versus nine, 19, and five QI reports and one, seven, and zero recalls for manually protocoled examinations. Retrospectively assigned protocols were concordant with 212/214 (99.1%) of automatically protocoled versus 233/236 (98.7%) of manually protocoled examinations. CONCLUSION. The automated protocoling system substantially reduced radiologists' protocoling workload and decreased times from order entry to protocol assignment and examination completion; protocol errors and recalls were infrequent. CLINICAL IMPACT. The system represents a solution for reducing radiologists' time spent performing noninterpretive tasks and improving care efficiency.

Errataetall:

CommentIn: AJR Am J Roentgenol. 2024 Jan 31;:. - PMID 38294165

Medienart:

E-Artikel

Erscheinungsjahr:

2024

Erschienen:

2024

Enthalten in:

Zur Gesamtaufnahme - year:2024

Enthalten in:

AJR. American journal of roentgenology - (2024) vom: 17. Apr., Seite 1-12

Sprache:

Englisch

Beteiligte Personen:

Chung, Ryan [VerfasserIn]
Demers, John P [VerfasserIn]
Tiberio, Roberta [VerfasserIn]
Savage, Cristy A [VerfasserIn]
McNulty, Frederick [VerfasserIn]
Stout, Markus [VerfasserIn]
Kambadakone, Avinash [VerfasserIn]
Gilman, Matthew D [VerfasserIn]
Sharma, Amita [VerfasserIn]
Alkasab, Tarik K [VerfasserIn]

Links:

Volltext

Themen:

Automated protocoling
Automatic protocoling
CT
Journal Article
Protocoling
Workflow

Anmerkungen:

Date Revised 17.04.2024

published: Print-Electronic

CommentIn: AJR Am J Roentgenol. 2024 Jan 31;:. - PMID 38294165

Citation Status Publisher

doi:

10.2214/AJR.23.29806

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

NLM367214571