Performance of dual-layer spectrum CT virtual monoenergetic images to assess early rectal adenocarcinoma T-stage : comparison with MR

© 2024. The Author(s)..

OBJECTIVES: To evaluate the image quality and utility of virtual monoenergetic images (VMI) of dual-layer spectrum computed tomography (DLSCT) in assessing preoperative T-stage for early rectal adenocarcinoma (ERA).

METHODS: This retrospective study included 67 ERA patients (mean age 62 ± 11.1 years) who underwent DLSCT and MR examination. VMI 40-200 keV and poly energetic image (PEI) were reconstructed. The image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and tumor contrast of different energy levels were calculated and compared, respectively. Two radiologists independently assess the image quality of the VMIs and PEI using 5-point scales. The diagnostic accuracies of DLSCT and HR-MRI for ERA T-staging were evaluated and compared.

RESULTS: The maximum noise was observed at VMI 40 keV, and noise at VMI 40-200 keV in the arterial and venous phases showed no significant difference (all p > 0.05). The highest SNR and CNR were obtained at VMI 40 keV, significantly greater than other energy levels and PEI (all p < 0.05). Tumor contrast was more evident than PEI at 40-100 keV in the arterial phase and at 40 keV in the venous phase (all p < 0.05). When compared with PEI, VMI 40 keV yielded the highest scores for overall image quality, tumor visibility, and tumor margin delineation, especially in the venous phase (p < 0.05). The overall diagnostic accuracy of DLSCT and HR-MRI for T-stage was 65.67 and 71.64% and showed no significant difference (p > 0.05).

CONCLUSIONS: VMI 40 keV improves image quality and accuracy in identifying lesions, providing better diagnostic information for ERA staging.

CRITICAL RELEVANCE STATEMENT: Low-keV VMI from DLSCT can improve tumor staging accuracy for early rectal carcinoma, helping guide surgical intervention decisions, and has shed new light on the potential breakthroughs of assessing preoperative T-stage in RC.

KEYPOINTS: • Compared with PEI, low-keV VIM derived from DLSCT, particularly at the 40 keV, significantly enhanced the objective and subjective image quality of ERA. • Using VMI 40 keV helped increase lesion detectability, leading to improved diagnostic accuracy for ERA. • Low-keV VMI from DLSCT has shed new light on the potential breakthroughs of assessing preoperative T-stage in RC.

Medienart:

E-Artikel

Erscheinungsjahr:

2024

Erschienen:

2024

Enthalten in:

Zur Gesamtaufnahme - volume:15

Enthalten in:

Insights into imaging - 15(2024), 1 vom: 17. Jan., Seite 11

Sprache:

Englisch

Beteiligte Personen:

Jia, Ziqi [VerfasserIn]
Guo, Lei [VerfasserIn]
Yuan, WenJing [VerfasserIn]
Dai, JianHao [VerfasserIn]
Lu, JianYe [VerfasserIn]
Li, ZhiQiang [VerfasserIn]
Du, Xiaohua [VerfasserIn]
Chen, Weicui [VerfasserIn]
Liu, Xian [VerfasserIn]

Links:

Volltext

Themen:

Dual-layer spectral detector CT
Early rectal adenocarcinoma
Journal Article
Magnetic resonance imaging
Tumor staging
Virtual monochromatic imaging

Anmerkungen:

Date Revised 19.01.2024

published: Electronic

Citation Status PubMed-not-MEDLINE

doi:

10.1186/s13244-023-01593-5

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

NLM367194562