Assessment of microcirculatory alteration by a vascular occlusion test using near-infrared spectroscopy in pediatric cardiac surgery : effect of cardiopulmonary bypass
OBJECTIVES: Cardiopulmonary bypass cause microcirculatory alterations. Near infrared spectroscopic measurement of tissue oxygen saturation and vascular occlusion test are novel technologies for assessing the microcirculatory function of peripheral tissue specifically in patients undergoing cardiac surgery with cardiopulmonary bypass.Our study aimed to evaluate dynamic microcirculatory function using the vascular occlusion testing during cardiac surgery in pediatric patients.
METHODS: 120 pediatric patients were scheduled. Children had continuous regional oxygen saturation monitoring using near infrared spectroscopy and vascular occlusion test. Vascular occlusion test was performed five times; before induction (T1), after induction (T2), then during cardiopulmonary bypass with full flow (T3), after the termination of CPB (T4) and after sternum closure (T5).
RESULTS: Basal value was the lowest at T3 and this value was significantly different among measurements (p < 0,01).Values for maximum and minimum tissue oxygen saturation were the lowest at T3 (83,4 and 52,9%).The occlusion slope varied significantly among measurements (p < 0,01).Reperfusion slopes were significantly different among measurements (p < 0,01) with a further progressive decrease in reperfusion slope with duration of cardiopulmonary bypass.
CONCLUSION: Microcirculatory function can assessed using VOT with forearm Near-infrared spectroscopy derived variables during cardiopulmonary bypass in pediatric cardiac surgery. Noninvasive assessment of microcirculatory perfusion during cardiopulmonary bypass can further help evaluate and improve circulatory support techniques.
TRIAL REGISTRATION: The research Project was registered at ClinicalTrials.gov (NCT06191913).
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:21 |
---|---|
Enthalten in: |
Expert review of medical devices - 21(2024), 3 vom: 31. März, Seite 249-255 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Savluk, Omer Faruk [VerfasserIn] |
---|
Links: |
---|
Themen: |
Clinical Study |
---|
Anmerkungen: |
Date Completed 18.03.2024 Date Revised 26.03.2024 published: Print-Electronic ClinicalTrials.gov: NCT06191913 Citation Status MEDLINE |
---|
doi: |
10.1080/17434440.2024.2306155 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM367079550 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM367079550 | ||
003 | DE-627 | ||
005 | 20240326235233.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240114s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1080/17434440.2024.2306155 |2 doi | |
028 | 5 | 2 | |a pubmed24n1348.xml |
035 | |a (DE-627)NLM367079550 | ||
035 | |a (NLM)38217402 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Savluk, Omer Faruk |e verfasserin |4 aut | |
245 | 1 | 0 | |a Assessment of microcirculatory alteration by a vascular occlusion test using near-infrared spectroscopy in pediatric cardiac surgery |b effect of cardiopulmonary bypass |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 18.03.2024 | ||
500 | |a Date Revised 26.03.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a ClinicalTrials.gov: NCT06191913 | ||
500 | |a Citation Status MEDLINE | ||
520 | |a OBJECTIVES: Cardiopulmonary bypass cause microcirculatory alterations. Near infrared spectroscopic measurement of tissue oxygen saturation and vascular occlusion test are novel technologies for assessing the microcirculatory function of peripheral tissue specifically in patients undergoing cardiac surgery with cardiopulmonary bypass.Our study aimed to evaluate dynamic microcirculatory function using the vascular occlusion testing during cardiac surgery in pediatric patients | ||
520 | |a METHODS: 120 pediatric patients were scheduled. Children had continuous regional oxygen saturation monitoring using near infrared spectroscopy and vascular occlusion test. Vascular occlusion test was performed five times; before induction (T1), after induction (T2), then during cardiopulmonary bypass with full flow (T3), after the termination of CPB (T4) and after sternum closure (T5) | ||
520 | |a RESULTS: Basal value was the lowest at T3 and this value was significantly different among measurements (p < 0,01).Values for maximum and minimum tissue oxygen saturation were the lowest at T3 (83,4 and 52,9%).The occlusion slope varied significantly among measurements (p < 0,01).Reperfusion slopes were significantly different among measurements (p < 0,01) with a further progressive decrease in reperfusion slope with duration of cardiopulmonary bypass | ||
520 | |a CONCLUSION: Microcirculatory function can assessed using VOT with forearm Near-infrared spectroscopy derived variables during cardiopulmonary bypass in pediatric cardiac surgery. Noninvasive assessment of microcirculatory perfusion during cardiopulmonary bypass can further help evaluate and improve circulatory support techniques | ||
520 | |a TRIAL REGISTRATION: The research Project was registered at ClinicalTrials.gov (NCT06191913) | ||
650 | 4 | |a Clinical Study | |
650 | 4 | |a Journal Article | |
650 | 4 | |a Microcirculation | |
650 | 4 | |a congenital cardiac surgery | |
650 | 4 | |a near-infrared spectroscopy | |
650 | 4 | |a pediatric cardiopulmonary bypass | |
650 | 4 | |a vascular occlusion test | |
700 | 1 | |a Yilmaz, Abdullah Arif |e verfasserin |4 aut | |
700 | 1 | |a Yavuz, Yasemin |e verfasserin |4 aut | |
700 | 1 | |a Arisut, Seda |e verfasserin |4 aut | |
700 | 1 | |a Ukil Isildak, Fatma |e verfasserin |4 aut | |
700 | 1 | |a Turkmen Karaagac, Aysu |e verfasserin |4 aut | |
700 | 1 | |a Ozbek, Baburhan |e verfasserin |4 aut | |
700 | 1 | |a Cine, Nihat |e verfasserin |4 aut | |
700 | 1 | |a Tuncer, Eylem |e verfasserin |4 aut | |
700 | 1 | |a Ceyran, Hakan |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Expert review of medical devices |d 2004 |g 21(2024), 3 vom: 31. März, Seite 249-255 |w (DE-627)NLM158941349 |x 1745-2422 |7 nnns |
773 | 1 | 8 | |g volume:21 |g year:2024 |g number:3 |g day:31 |g month:03 |g pages:249-255 |
856 | 4 | 0 | |u http://dx.doi.org/10.1080/17434440.2024.2306155 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 21 |j 2024 |e 3 |b 31 |c 03 |h 249-255 |