Inter-arm blood pressure difference in post-stroke patients with hemiparesis
© 2023. The Author(s), under exclusive licence to Springer Nature Limited..
The aim of this study was to investigate that inter-arm blood pressure (BP) difference (IAD) and reference arm in 420 post-stroke patients with hemiparesis. Synchronous bilateral-arm BP was measured with two automatic BP devices, and the systolic BP difference of ≥10 mm Hg was recorded as increased sIAD. The arm with higher systolic BP (SBP) was assigned as the reference arm. Our results showed that the prevalence of sIAD was 18.1% in the total group. The paretic arms had similar mean SBP levels (133.6±18.4 vs. 133.8±18.4 mm Hg, NS) and DBP (77.8±11.5 vs. 77.2±10.9 mm Hg, NS) as compared with the unaffected arms. The detection rate of hypertension or uncontrolled hypertension on the SBP values of the reference arm was higher than that on the unaffected arm (41.8% vs. 36.3%). It is concluded that in the post-stroke patients with hemiparesis in the rehabilitation period, the prevalence of sIAD ≥10 mmHg was relatively higher, and using the unaffected arm, rather than the unaffected arm, for BP measurement could induce correctly detection of hypertension.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:38 |
---|---|
Enthalten in: |
Journal of human hypertension - 38(2024), 3 vom: 11. März, Seite 228-231 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Peng, Hai-Ping [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 18.03.2024 Date Revised 17.04.2024 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1038/s41371-023-00886-y |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM366421794 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM366421794 | ||
003 | DE-627 | ||
005 | 20240418232425.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231229s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1038/s41371-023-00886-y |2 doi | |
028 | 5 | 2 | |a pubmed24n1379.xml |
035 | |a (DE-627)NLM366421794 | ||
035 | |a (NLM)38151538 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Peng, Hai-Ping |e verfasserin |4 aut | |
245 | 1 | 0 | |a Inter-arm blood pressure difference in post-stroke patients with hemiparesis |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 18.03.2024 | ||
500 | |a Date Revised 17.04.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2023. The Author(s), under exclusive licence to Springer Nature Limited. | ||
520 | |a The aim of this study was to investigate that inter-arm blood pressure (BP) difference (IAD) and reference arm in 420 post-stroke patients with hemiparesis. Synchronous bilateral-arm BP was measured with two automatic BP devices, and the systolic BP difference of ≥10 mm Hg was recorded as increased sIAD. The arm with higher systolic BP (SBP) was assigned as the reference arm. Our results showed that the prevalence of sIAD was 18.1% in the total group. The paretic arms had similar mean SBP levels (133.6±18.4 vs. 133.8±18.4 mm Hg, NS) and DBP (77.8±11.5 vs. 77.2±10.9 mm Hg, NS) as compared with the unaffected arms. The detection rate of hypertension or uncontrolled hypertension on the SBP values of the reference arm was higher than that on the unaffected arm (41.8% vs. 36.3%). It is concluded that in the post-stroke patients with hemiparesis in the rehabilitation period, the prevalence of sIAD ≥10 mmHg was relatively higher, and using the unaffected arm, rather than the unaffected arm, for BP measurement could induce correctly detection of hypertension | ||
650 | 4 | |a Journal Article | |
700 | 1 | |a Tao, Liang |e verfasserin |4 aut | |
700 | 1 | |a Tang, Min |e verfasserin |4 aut | |
700 | 1 | |a Su, Hai |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of human hypertension |d 1996 |g 38(2024), 3 vom: 11. März, Seite 228-231 |w (DE-627)NLM012646121 |x 1476-5527 |7 nnns |
773 | 1 | 8 | |g volume:38 |g year:2024 |g number:3 |g day:11 |g month:03 |g pages:228-231 |
856 | 4 | 0 | |u http://dx.doi.org/10.1038/s41371-023-00886-y |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 38 |j 2024 |e 3 |b 11 |c 03 |h 228-231 |