An in silico testbed for fast and accurate MR labeling of orthopedic implants
© 2023, Noetscher, Serano et al..
One limitation on the ability to monitor health in older adults using magnetic resonance (MR) imaging is the presence of implants, where the prevalence of implantable devices (orthopedic, cardiac, neuromodulation) increases in the population, as does the pervasiveness of conditions requiring MRI studies for diagnosis (musculoskeletal diseases, infections, or cancer). The present study describes a novel multiphysics implant modeling testbed using the following approaches with two examples: (1) an in silico human model based on the widely available Visible Human Project (VHP) cryo-section dataset; (2) a finite element method (FEM) modeling software workbench from Ansys (Electronics Desktop/Mechanical) to model MR radio frequency (RF) coils and the temperature rise modeling in heterogeneous media. The in silico VHP-Female model (250 parts with an additional 40 components specifically characterizing embedded implants and resultant surrounding tissues) corresponds to a 60-year-old female with a body mass index of 36. The testbed includes the FEM-compatible in silico human model, an implant embedding procedure, a generic parameterizable MRI RF birdcage two-port coil model, a workflow for computing heat sources on the implant surface and in adjacent tissues, and a thermal FEM solver directly linked to the MR coil simulator to determine implant heating based on an MR imaging study protocol. The primary target is MR labeling of large orthopedic implants. The testbed has very recently been approved by the US Food and Drug Administration (FDA) as a medical device development tool for 1.5 T orthopedic implant examinations.
Errataetall: | |
---|---|
Medienart: |
E-Artikel |
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:12 |
---|---|
Enthalten in: |
eLife - 12(2023) vom: 14. Dez. |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Noetscher, Gregory M [VerfasserIn] |
---|
Links: |
---|
Themen: |
Case Reports |
---|
Anmerkungen: |
Date Completed 16.12.2023 Date Revised 21.12.2023 published: Electronic Dryad: 10.5061/dryad.2jm63xswt UpdateOf: bioRxiv. 2023 Oct 02;:. - PMID 37649909 Citation Status MEDLINE |
---|
doi: |
10.7554/eLife.90440 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM365868035 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM365868035 | ||
003 | DE-627 | ||
005 | 20231227135456.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.7554/eLife.90440 |2 doi | |
028 | 5 | 2 | |a pubmed24n1234.xml |
035 | |a (DE-627)NLM365868035 | ||
035 | |a (NLM)38096104 | ||
035 | |a (PII)RP90440 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Noetscher, Gregory M |e verfasserin |4 aut | |
245 | 1 | 3 | |a An in silico testbed for fast and accurate MR labeling of orthopedic implants |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 16.12.2023 | ||
500 | |a Date Revised 21.12.2023 | ||
500 | |a published: Electronic | ||
500 | |a Dryad: 10.5061/dryad.2jm63xswt | ||
500 | |a UpdateOf: bioRxiv. 2023 Oct 02;:. - PMID 37649909 | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2023, Noetscher, Serano et al. | ||
520 | |a One limitation on the ability to monitor health in older adults using magnetic resonance (MR) imaging is the presence of implants, where the prevalence of implantable devices (orthopedic, cardiac, neuromodulation) increases in the population, as does the pervasiveness of conditions requiring MRI studies for diagnosis (musculoskeletal diseases, infections, or cancer). The present study describes a novel multiphysics implant modeling testbed using the following approaches with two examples: (1) an in silico human model based on the widely available Visible Human Project (VHP) cryo-section dataset; (2) a finite element method (FEM) modeling software workbench from Ansys (Electronics Desktop/Mechanical) to model MR radio frequency (RF) coils and the temperature rise modeling in heterogeneous media. The in silico VHP-Female model (250 parts with an additional 40 components specifically characterizing embedded implants and resultant surrounding tissues) corresponds to a 60-year-old female with a body mass index of 36. The testbed includes the FEM-compatible in silico human model, an implant embedding procedure, a generic parameterizable MRI RF birdcage two-port coil model, a workflow for computing heat sources on the implant surface and in adjacent tissues, and a thermal FEM solver directly linked to the MR coil simulator to determine implant heating based on an MR imaging study protocol. The primary target is MR labeling of large orthopedic implants. The testbed has very recently been approved by the US Food and Drug Administration (FDA) as a medical device development tool for 1.5 T orthopedic implant examinations | ||
650 | 4 | |a Case Reports | |
650 | 4 | |a Journal Article | |
650 | 4 | |a MR imaging studies | |
650 | 4 | |a MR safety/labeling | |
650 | 4 | |a human | |
650 | 4 | |a multiphysics modeling | |
650 | 4 | |a orthopedic impants | |
650 | 4 | |a physics of living systems | |
650 | 4 | |a temperature rise | |
700 | 1 | |a Serano, Peter J |e verfasserin |4 aut | |
700 | 1 | |a Horner, Marc |e verfasserin |4 aut | |
700 | 1 | |a Prokop, Alexander |e verfasserin |4 aut | |
700 | 1 | |a Hanson, Jonathan |e verfasserin |4 aut | |
700 | 1 | |a Fujimoto, Kyoko |e verfasserin |4 aut | |
700 | 1 | |a Brown, James |e verfasserin |4 aut | |
700 | 1 | |a Nazarian, Ara |e verfasserin |4 aut | |
700 | 1 | |a Ackerman, Jerome |e verfasserin |4 aut | |
700 | 1 | |a Makaroff, Sergey N |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t eLife |d 2012 |g 12(2023) vom: 14. Dez. |w (DE-627)NLM221831460 |x 2050-084X |7 nnns |
773 | 1 | 8 | |g volume:12 |g year:2023 |g day:14 |g month:12 |
856 | 4 | 0 | |u http://dx.doi.org/10.7554/eLife.90440 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 12 |j 2023 |b 14 |c 12 |