Instantaneous extracellular solution exchange for concurrent evaluation of membrane permeability of single cells

The osmotic stress imposed on microorganisms by hypotonic conditions is perceived to regulate water and solute flux via cell membranes, which are crucial for survival. Some cells that fail to perceive osmotic stress die because this results in the rupture of the cell membrane. The flux through the membrane is characterized by the membrane permeability, which is measured using a stopped-flow apparatus in response to a millisecond-order osmolarity change. However, the obtained data are an ensemble average of each cell response. Additionally, the measurement of permeability, considering cellular viability, contributes to a more accurate evaluation of osmoadaptation. Here, we present a novel on-chip instantaneous extracellular solution exchange method using an air-liquid interface. The presented method provides a concurrent evaluation at the single-cell level in response to a millisecond-order osmotic shock, considering cellular viability by solution exchange. This method utilizes a liquid bridge with a locally formed droplet on the surface of a micropillar fabricated inside a microchannel. We evaluated a solution exchange time of 3.6 ms and applied this method to Synechocystis PCC 6803 under two different osmolarity conditions. The live/dead ratio of 1 M to 0.5 M osmotic down shock condition was 78.8/21.2% while that of 1 M to 0.25 M osmotic down shock condition was 40.0/60.0%. We evaluated the water permeability of two groups: cells that were still live before and after osmotic shock (hereafter named cell type 1), and cells that were live before but were dead 10 minutes after osmotic shock (hereafter named cell type 2). The results indicated that the water permeability of cell type 2 was higher than that of cell type 1. The results obtained using the presented methods confirmed that the effect of osmotic stress can be accurately evaluated using single-cell analysis.

Medienart:

E-Artikel

Erscheinungsjahr:

2024

Erschienen:

2024

Enthalten in:

Zur Gesamtaufnahme - volume:24

Enthalten in:

Lab on a chip - 24(2024), 2 vom: 17. Jan., Seite 281-291

Sprache:

Englisch

Beteiligte Personen:

Kaneko, Shingo [VerfasserIn]
Hirotaka, Sugiura [VerfasserIn]
Tsujii, Masaru [VerfasserIn]
Maruyama, Hisataka [VerfasserIn]
Uozumi, Nobuyuki [VerfasserIn]
Arai, Fumihito [VerfasserIn]

Links:

Volltext

Themen:

059QF0KO0R
Journal Article
Research Support, Non-U.S. Gov't
Water

Anmerkungen:

Date Completed 18.01.2024

Date Revised 29.02.2024

published: Electronic

Citation Status MEDLINE

doi:

10.1039/d3lc00633f

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

NLM365774340