Biomechanical characteristics of a novel interspinous distraction fusion device in the treatment of lumbar degenerative diseases : a finite element analysis

© 2023. The Author(s)..

BACKGROUND: A novel interspinous distraction fusion (ISDF) device has been used to treat lumbar degenerative diseases. As a minimally invasive technique, ISDF differs from the traditional interspinous process distraction devices. Currently, biomechanical studies on ISDF are rare.

OBJECTIVE: To investigate the biomechanical properties of the ISDF device (BacFuse) which is used to treat lumbar degenerative diseases.

METHODS: Three-dimensional L3-L5 models were created. The models were divided into four groups: intact (M1), local decompression alone (M2), internal fixation alone (M3) and local decompression combined with internal fixation (M4), based on different surgical procedures. Local laminectomy was performed to resect the lower part of the L4 lamina and the upper part of the L5 lamina at the right lamina of L4/5 in the M2 and M4 groups. After meshing the models elements, Abaqus were used to perform the finite element (FE) analysis. The intervertebral range of motion (ROM) was measured during flexion, extension, left lateral bending, right lateral bending, left rotation and right rotation under a follower load of 400 N with a 7.5Nm moment. The distributions of disc and facet joint stresses were observed and recorded. Spinal vertebral stress was compared, and internal fixation device stress was observed.

RESULTS: The ROM of L4/5 in M2 increased in flexion, extension, left lateral bending, right lateral bending, left rotation and right rotation compared with that in M1. In all motion directions, the ROM at L4/5 decreased, and the ROM at L3/4 increased after implantation of the ISDF device in M3 and M4 groups. The disc stress and facet joint stresses in the instrumented segment decreased after implantation of the ISDF device. The spinous process loaded a certain amount of stress in M3 and M4 groups. The spikes of the internal fixation device were loaded with the maximum stress.

CONCLUSION: BacFuse exhibited a reduction in intervertebral ROM, as well as decreased stress on the intervertebral disc and facet joint, while also demonstrating a discernible impact on the upper adjacent segment.

Medienart:

E-Artikel

Erscheinungsjahr:

2023

Erschienen:

2023

Enthalten in:

Zur Gesamtaufnahme - volume:24

Enthalten in:

BMC musculoskeletal disorders - 24(2023), 1 vom: 06. Dez., Seite 944

Sprache:

Englisch

Beteiligte Personen:

Chen, Mengmeng [VerfasserIn]
Deng, Jiechao [VerfasserIn]
Bao, Li [VerfasserIn]
Jia, Pu [VerfasserIn]
Feng, Fei [VerfasserIn]
Shi, Guan [VerfasserIn]
Tang, Hai [VerfasserIn]
Chen, Hao [VerfasserIn]

Links:

Volltext

Themen:

Biomechanical properties
Finite element analysis
Interspinous distraction fusion device
Journal Article
Lumbar degenerative diseases

Anmerkungen:

Date Completed 11.12.2023

Date Revised 11.12.2023

published: Electronic

Citation Status MEDLINE

doi:

10.1186/s12891-023-07066-6

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

NLM365486434