Anti-Xa Assay Monitoring Improves the Precision of Anticoagulation in Venovenous Extracorporeal Membrane Oxygenation
Copyright © ASAIO 2023..
Unfractionated heparin (UFH) is the most used anticoagulant in patients receiving veno-venous extracorporeal membrane oxygenation (VV-ECMO). Its therapeutic levels are monitored using activated partial thromboplastin time ratio (aPTTr) or antifactor Xa (anti-Xa) assay. This was a retrospective, single-center, cohort study where all adult patients with viral etiology respiratory failure requiring VV-ECMO from January 2, 2015 to January 31, 2022 were included. Anticoagulation was monitored using aPTTr (until November 1, 2019) or anti-Xa assay (after November 1, 2019). We compared the accuracy and precision of anticoagulation monitoring tests using time in therapeutic range (TTR) and variance growth rate (VGR), respectively, and their impact on bleeding and thrombotic events (BTEs). A total of 254 patients, 74 in aPTTr and 180 in anti-Xa monitoring groups, were included with a total of 4,992 ECMO-person days. Accuracy was comparable: mean TTR of 47% in aPTTr and 51% in anti-Xa groups ( p = 0.28). Antifactor Xa monitoring group demonstrated improved precision with a lower variance (median VGR 0.21 vs. 1.61 in aPTTr, p < 0.05). Secondary outcome of less heparin prescription changes (adjusted rate ratio [RR] = 1.01, p = 0.01), fewer blood transfusions (adjusted RR = 0.78, p < 0.05), and ECMO circuit changes (adjusted RR = 0.68, p < 0.05) were seen with anti-Xa monitoring.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:70 |
---|---|
Enthalten in: |
ASAIO journal (American Society for Artificial Internal Organs : 1992) - 70(2024), 4 vom: 01. Apr., Seite 313-320 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Hla, Teddy Tun Win [VerfasserIn] |
---|
Links: |
---|
Themen: |
9005-49-6 |
---|
Anmerkungen: |
Date Completed 03.04.2024 Date Revised 03.04.2024 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1097/MAT.0000000000002100 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM365305464 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM365305464 | ||
003 | DE-627 | ||
005 | 20240403235056.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1097/MAT.0000000000002100 |2 doi | |
028 | 5 | 2 | |a pubmed24n1363.xml |
035 | |a (DE-627)NLM365305464 | ||
035 | |a (NLM)38039550 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Hla, Teddy Tun Win |e verfasserin |4 aut | |
245 | 1 | 0 | |a Anti-Xa Assay Monitoring Improves the Precision of Anticoagulation in Venovenous Extracorporeal Membrane Oxygenation |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 03.04.2024 | ||
500 | |a Date Revised 03.04.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © ASAIO 2023. | ||
520 | |a Unfractionated heparin (UFH) is the most used anticoagulant in patients receiving veno-venous extracorporeal membrane oxygenation (VV-ECMO). Its therapeutic levels are monitored using activated partial thromboplastin time ratio (aPTTr) or antifactor Xa (anti-Xa) assay. This was a retrospective, single-center, cohort study where all adult patients with viral etiology respiratory failure requiring VV-ECMO from January 2, 2015 to January 31, 2022 were included. Anticoagulation was monitored using aPTTr (until November 1, 2019) or anti-Xa assay (after November 1, 2019). We compared the accuracy and precision of anticoagulation monitoring tests using time in therapeutic range (TTR) and variance growth rate (VGR), respectively, and their impact on bleeding and thrombotic events (BTEs). A total of 254 patients, 74 in aPTTr and 180 in anti-Xa monitoring groups, were included with a total of 4,992 ECMO-person days. Accuracy was comparable: mean TTR of 47% in aPTTr and 51% in anti-Xa groups ( p = 0.28). Antifactor Xa monitoring group demonstrated improved precision with a lower variance (median VGR 0.21 vs. 1.61 in aPTTr, p < 0.05). Secondary outcome of less heparin prescription changes (adjusted rate ratio [RR] = 1.01, p = 0.01), fewer blood transfusions (adjusted RR = 0.78, p < 0.05), and ECMO circuit changes (adjusted RR = 0.68, p < 0.05) were seen with anti-Xa monitoring | ||
650 | 4 | |a Journal Article | |
650 | 7 | |a Heparin |2 NLM | |
650 | 7 | |a 9005-49-6 |2 NLM | |
650 | 7 | |a Factor Xa Inhibitors |2 NLM | |
650 | 7 | |a Anticoagulants |2 NLM | |
700 | 1 | |a Christou, Silvana |e verfasserin |4 aut | |
700 | 1 | |a Sanderson, Barnaby |e verfasserin |4 aut | |
700 | 1 | |a Hanks, Fraser |e verfasserin |4 aut | |
700 | 1 | |a Cameron, Lynda |e verfasserin |4 aut | |
700 | 1 | |a Camporota, Luigi |e verfasserin |4 aut | |
700 | 1 | |a Doyle, Andrew J |e verfasserin |4 aut | |
700 | 1 | |a Retter, Andrew |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t ASAIO journal (American Society for Artificial Internal Organs : 1992) |d 1997 |g 70(2024), 4 vom: 01. Apr., Seite 313-320 |w (DE-627)NLM012606766 |x 1538-943X |7 nnns |
773 | 1 | 8 | |g volume:70 |g year:2024 |g number:4 |g day:01 |g month:04 |g pages:313-320 |
856 | 4 | 0 | |u http://dx.doi.org/10.1097/MAT.0000000000002100 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 70 |j 2024 |e 4 |b 01 |c 04 |h 313-320 |