Evaluation of two automated real-time PCR-based quantification methods for whole blood Epstein-Barr viral load
Copyright © 2023 Elsevier Inc. All rights reserved..
Quantification of EBV DNA is important in transplantation settings for the diagnosis of post-transplantation. We evaluated the performance of the AltoStar® EBV PCR Kit 1.5 on whole blood specimens: limit of detection, linearity, accuracy, and precision were determined using the WHO NIBSC 09/260 international standard. Results of 69 clinical samples were compared between the AltoStar® EBV PCR Kit 1.5 (altona Diagnostics) and the RealTime EBV assay (Abbott). The LoD of the AltoStar® Kit was 148 IU/mL and linearity was between 375 and 500000. A high concordance was found between nominal value of the NIBSC dilutions and the AltoStar EBV result. The total variation ranged from 2.2% to 9.6%. Out of 69 clinical samples tested, there was a high concordance between the 22 paired results within the overlapping linear ranges of both tests. The AltoStar® EBV assay is reliable and accurate for EBV viral load determination on whole blood samples.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:108 |
---|---|
Enthalten in: |
Diagnostic microbiology and infectious disease - 108(2024), 2 vom: 01. Jan., Seite 116101 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Vancutsem, Ellen [VerfasserIn] |
---|
Links: |
---|
Themen: |
AltoStar® |
---|
Anmerkungen: |
Date Completed 22.01.2024 Date Revised 22.01.2024 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.diagmicrobio.2023.116101 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM365075566 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM365075566 | ||
003 | DE-627 | ||
005 | 20240122231944.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.diagmicrobio.2023.116101 |2 doi | |
028 | 5 | 2 | |a pubmed24n1267.xml |
035 | |a (DE-627)NLM365075566 | ||
035 | |a (NLM)38016384 | ||
035 | |a (PII)S0732-8893(23)00210-9 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Vancutsem, Ellen |e verfasserin |4 aut | |
245 | 1 | 0 | |a Evaluation of two automated real-time PCR-based quantification methods for whole blood Epstein-Barr viral load |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 22.01.2024 | ||
500 | |a Date Revised 22.01.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2023 Elsevier Inc. All rights reserved. | ||
520 | |a Quantification of EBV DNA is important in transplantation settings for the diagnosis of post-transplantation. We evaluated the performance of the AltoStar® EBV PCR Kit 1.5 on whole blood specimens: limit of detection, linearity, accuracy, and precision were determined using the WHO NIBSC 09/260 international standard. Results of 69 clinical samples were compared between the AltoStar® EBV PCR Kit 1.5 (altona Diagnostics) and the RealTime EBV assay (Abbott). The LoD of the AltoStar® Kit was 148 IU/mL and linearity was between 375 and 500000. A high concordance was found between nominal value of the NIBSC dilutions and the AltoStar EBV result. The total variation ranged from 2.2% to 9.6%. Out of 69 clinical samples tested, there was a high concordance between the 22 paired results within the overlapping linear ranges of both tests. The AltoStar® EBV assay is reliable and accurate for EBV viral load determination on whole blood samples | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a AltoStar® | |
650 | 4 | |a Epstein-Barr Virus | |
650 | 4 | |a Viral load | |
650 | 4 | |a Whole blood | |
650 | 4 | |a m2000 | |
650 | 7 | |a DNA, Viral |2 NLM | |
700 | 1 | |a Crombé, Florence |e verfasserin |4 aut | |
700 | 1 | |a Soetens, Oriane |e verfasserin |4 aut | |
700 | 1 | |a Wautier, Magali |e verfasserin |4 aut | |
700 | 1 | |a Dördelmann, Corinna |e verfasserin |4 aut | |
700 | 1 | |a Piérard, Denis |e verfasserin |4 aut | |
700 | 1 | |a Wybo, Ingrid |e verfasserin |4 aut | |
700 | 1 | |a Demuyser, Thomas |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Diagnostic microbiology and infectious disease |d 1986 |g 108(2024), 2 vom: 01. Jan., Seite 116101 |w (DE-627)NLM01262845X |x 1879-0070 |7 nnns |
773 | 1 | 8 | |g volume:108 |g year:2024 |g number:2 |g day:01 |g month:01 |g pages:116101 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.diagmicrobio.2023.116101 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 108 |j 2024 |e 2 |b 01 |c 01 |h 116101 |