Near-Infrared Rechargeable Persistent Luminescence Nanoparticles for Biomedical Implants In Vivo Noninvasive Bioimaging
Luminescent imaging has garnered significant attention for in vivo tracking of biomedical implants during and after surgery due to its human friendliness, affordability, and high sensitivity. However, conventional fluorescent probes are susceptible to background autofluorescence interference from living tissues, often resulting in poor signal-to-noise ratios. Herein, we report a background interference-free persistent luminescent implant (PLI) with excellent persistent luminescence (PL) performance, which can be clearly and long-term detected by an optical imaging system after implantation. Rechargeable near-infrared persistent luminescence nanoparticles (PLNPs) were prepared first via a simple hydrothermal approach and then modified by PEGylation to improve their hydrophilicity, biocompatibility, and compatibility with polymer substrates. The PEGylated PLNPs were facilely complexed into a polymer matrix to fabricate the PLI. The obtained PLIs can well inherit the PL properties of PLNPs, exhibiting good PL optical imaging performance without tissue autofluorescence interference. Furthermore, both PLNPs and PLIs possess good biocompatibility, and the addition of PLNPs has no negative impact on the biocompatibility of the polymer matrix. This work fully utilizes the luminescent properties of PLNPs and adapts this PL to the field of biomedical implant imaging, which provides new insight for designing biomedical imaging systems.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:15 |
---|---|
Enthalten in: |
ACS applied materials & interfaces - 15(2023), 46 vom: 22. Nov., Seite 53310-53317 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Fu, Daihua [VerfasserIn] |
---|
Links: |
---|
Themen: |
Autofluorescence-free |
---|
Anmerkungen: |
Date Completed 23.11.2023 Date Revised 23.11.2023 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1021/acsami.3c12947 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM364389850 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM364389850 | ||
003 | DE-627 | ||
005 | 20231226095330.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1021/acsami.3c12947 |2 doi | |
028 | 5 | 2 | |a pubmed24n1214.xml |
035 | |a (DE-627)NLM364389850 | ||
035 | |a (NLM)37947316 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Fu, Daihua |e verfasserin |4 aut | |
245 | 1 | 0 | |a Near-Infrared Rechargeable Persistent Luminescence Nanoparticles for Biomedical Implants In Vivo Noninvasive Bioimaging |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 23.11.2023 | ||
500 | |a Date Revised 23.11.2023 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Luminescent imaging has garnered significant attention for in vivo tracking of biomedical implants during and after surgery due to its human friendliness, affordability, and high sensitivity. However, conventional fluorescent probes are susceptible to background autofluorescence interference from living tissues, often resulting in poor signal-to-noise ratios. Herein, we report a background interference-free persistent luminescent implant (PLI) with excellent persistent luminescence (PL) performance, which can be clearly and long-term detected by an optical imaging system after implantation. Rechargeable near-infrared persistent luminescence nanoparticles (PLNPs) were prepared first via a simple hydrothermal approach and then modified by PEGylation to improve their hydrophilicity, biocompatibility, and compatibility with polymer substrates. The PEGylated PLNPs were facilely complexed into a polymer matrix to fabricate the PLI. The obtained PLIs can well inherit the PL properties of PLNPs, exhibiting good PL optical imaging performance without tissue autofluorescence interference. Furthermore, both PLNPs and PLIs possess good biocompatibility, and the addition of PLNPs has no negative impact on the biocompatibility of the polymer matrix. This work fully utilizes the luminescent properties of PLNPs and adapts this PL to the field of biomedical implant imaging, which provides new insight for designing biomedical imaging systems | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a autofluorescence-free | |
650 | 4 | |a bioimaging | |
650 | 4 | |a biomedical implants | |
650 | 4 | |a near-infrared rechargeable PLNPs | |
650 | 4 | |a persistent luminescence nanoparticles | |
650 | 7 | |a Fluorescent Dyes |2 NLM | |
650 | 7 | |a Polymers |2 NLM | |
700 | 1 | |a Yang, Fan |e verfasserin |4 aut | |
700 | 1 | |a Zhang, Jiayi |e verfasserin |4 aut | |
700 | 1 | |a Xiang, Zhen |e verfasserin |4 aut | |
700 | 1 | |a Wang, Yunbing |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t ACS applied materials & interfaces |d 2009 |g 15(2023), 46 vom: 22. Nov., Seite 53310-53317 |w (DE-627)NLM194100049 |x 1944-8252 |7 nnns |
773 | 1 | 8 | |g volume:15 |g year:2023 |g number:46 |g day:22 |g month:11 |g pages:53310-53317 |
856 | 4 | 0 | |u http://dx.doi.org/10.1021/acsami.3c12947 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 15 |j 2023 |e 46 |b 22 |c 11 |h 53310-53317 |