Digitally designed and manufactured sectional custom tray for a patient with microstomia : A case report
© 2023 by the American College of Prosthodontists..
Microstomia presents a challenge for the patient and dental provider. This report describes a partial digital workflow for the fabrication of a mandibular complete denture for a patient with microstomia. Computer-aided design and computer-aided manufacturing technology was utilized to 3D print a sectional custom tray with a unique design. The sectional custom tray was used to make a conventional border molded impression of the edentulous arch to fabricate a flexible complete mandibular denture for a 58-year-old female patient with scleroderma and microstomia. This treatment resulted in a successful prosthetic outcome and high patient satisfaction.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:33 |
---|---|
Enthalten in: |
Journal of prosthodontics : official journal of the American College of Prosthodontists - 33(2024), 4 vom: 04. Apr., Seite 307-312 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Jagielska, Marika [VerfasserIn] |
---|
Links: |
---|
Themen: |
CAD‐CAM |
---|
Anmerkungen: |
Date Completed 12.04.2024 Date Revised 12.04.2024 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1111/jopr.13789 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM364189592 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM364189592 | ||
003 | DE-627 | ||
005 | 20240412232548.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1111/jopr.13789 |2 doi | |
028 | 5 | 2 | |a pubmed24n1373.xml |
035 | |a (DE-627)NLM364189592 | ||
035 | |a (NLM)37927117 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Jagielska, Marika |e verfasserin |4 aut | |
245 | 1 | 0 | |a Digitally designed and manufactured sectional custom tray for a patient with microstomia |b A case report |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 12.04.2024 | ||
500 | |a Date Revised 12.04.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2023 by the American College of Prosthodontists. | ||
520 | |a Microstomia presents a challenge for the patient and dental provider. This report describes a partial digital workflow for the fabrication of a mandibular complete denture for a patient with microstomia. Computer-aided design and computer-aided manufacturing technology was utilized to 3D print a sectional custom tray with a unique design. The sectional custom tray was used to make a conventional border molded impression of the edentulous arch to fabricate a flexible complete mandibular denture for a 58-year-old female patient with scleroderma and microstomia. This treatment resulted in a successful prosthetic outcome and high patient satisfaction | ||
650 | 4 | |a Case Reports | |
650 | 4 | |a Journal Article | |
650 | 4 | |a CAD‐CAM | |
650 | 4 | |a microstomia | |
650 | 4 | |a scleroderma | |
650 | 4 | |a sectional tray | |
700 | 1 | |a Somohano-Marquez, Tanya |e verfasserin |4 aut | |
700 | 1 | |a Delgado-Ruiz, Rafael |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of prosthodontics : official journal of the American College of Prosthodontists |d 1996 |g 33(2024), 4 vom: 04. Apr., Seite 307-312 |w (DE-627)NLM012891819 |x 1532-849X |7 nnns |
773 | 1 | 8 | |g volume:33 |g year:2024 |g number:4 |g day:04 |g month:04 |g pages:307-312 |
856 | 4 | 0 | |u http://dx.doi.org/10.1111/jopr.13789 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 33 |j 2024 |e 4 |b 04 |c 04 |h 307-312 |