Miniaturized paper-based analytical device for the portable analysis of phyto-cannabinoids in plant and oral fluids
© 2023. The Author(s)..
In this work, a low-cost and eco-friendly paper-based analytical device (PAD) method is described for the determination of phyto-cannabinoids in cannabis and oral fluids based on a simple colorimetric reaction. The PAD was able to distinguish tetrahydrocannabinol (THC)- and cannabidiol (CBD)-rich plant samples by using 4-aminophenol (4-AP) and later on to quantify total phyto-cannabinoid content (THC + CBD + CBN) in plant and oral fluids by using the Fast Corinth V reagent. The chemical and physical properties regarding paper type and reagent concentration in the PAD were optimized to achieve the best analytical performance. After that, analytical features were obtained, including a linear range of 0.01-0.1 mg mL-1, a limit of detection (LOD) of 0.003 mg mL-1, and a suitable precision, expressed as relative standard deviation (RSD) lower than 10%. Furthermore, no significant interferences were observed in colorimetric reactions when tea, herbs, and drug samples were analyzed. Additionally, the PAD proved color stability up to 1 month after the sampling at 25 °C. The developed PAD was suitable for determining total phyto-cannabinoid content in plants and oral fluids, obtaining good results compared to GC-MS. Overall, this method showed good reliability resulting in an operational on-site device for drug monitoring.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:416 |
---|---|
Enthalten in: |
Analytical and bioanalytical chemistry - 416(2024), 1 vom: 01. Jan., Seite 255-264 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Houtzager, Dymphy [VerfasserIn] |
---|
Links: |
---|
Themen: |
19GBJ60SN5 |
---|
Anmerkungen: |
Date Completed 03.01.2024 Date Revised 04.01.2024 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1007/s00216-023-05013-x |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM364162287 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM364162287 | ||
003 | DE-627 | ||
005 | 20240108141651.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1007/s00216-023-05013-x |2 doi | |
028 | 5 | 2 | |a pubmed24n1248.xml |
035 | |a (DE-627)NLM364162287 | ||
035 | |a (NLM)37924377 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Houtzager, Dymphy |e verfasserin |4 aut | |
245 | 1 | 0 | |a Miniaturized paper-based analytical device for the portable analysis of phyto-cannabinoids in plant and oral fluids |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 03.01.2024 | ||
500 | |a Date Revised 04.01.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2023. The Author(s). | ||
520 | |a In this work, a low-cost and eco-friendly paper-based analytical device (PAD) method is described for the determination of phyto-cannabinoids in cannabis and oral fluids based on a simple colorimetric reaction. The PAD was able to distinguish tetrahydrocannabinol (THC)- and cannabidiol (CBD)-rich plant samples by using 4-aminophenol (4-AP) and later on to quantify total phyto-cannabinoid content (THC + CBD + CBN) in plant and oral fluids by using the Fast Corinth V reagent. The chemical and physical properties regarding paper type and reagent concentration in the PAD were optimized to achieve the best analytical performance. After that, analytical features were obtained, including a linear range of 0.01-0.1 mg mL-1, a limit of detection (LOD) of 0.003 mg mL-1, and a suitable precision, expressed as relative standard deviation (RSD) lower than 10%. Furthermore, no significant interferences were observed in colorimetric reactions when tea, herbs, and drug samples were analyzed. Additionally, the PAD proved color stability up to 1 month after the sampling at 25 °C. The developed PAD was suitable for determining total phyto-cannabinoid content in plants and oral fluids, obtaining good results compared to GC-MS. Overall, this method showed good reliability resulting in an operational on-site device for drug monitoring | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Cannabis | |
650 | 4 | |a Colorimetry | |
650 | 4 | |a On-site analysis | |
650 | 4 | |a Paper-based device | |
650 | 4 | |a Phyto-cannabinoids | |
650 | 7 | |a Cannabinoids |2 NLM | |
650 | 7 | |a Dronabinol |2 NLM | |
650 | 7 | |a 7J8897W37S |2 NLM | |
650 | 7 | |a Cannabidiol |2 NLM | |
650 | 7 | |a 19GBJ60SN5 |2 NLM | |
700 | 1 | |a Armenta, Sergio |e verfasserin |4 aut | |
700 | 1 | |a Herrero-Martínez, José Manuel |e verfasserin |4 aut | |
700 | 1 | |a Martínez-Pérez-Cejuela, Héctor |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Analytical and bioanalytical chemistry |d 1995 |g 416(2024), 1 vom: 01. Jan., Seite 255-264 |w (DE-627)NLM118176722 |x 1618-2650 |7 nnns |
773 | 1 | 8 | |g volume:416 |g year:2024 |g number:1 |g day:01 |g month:01 |g pages:255-264 |
856 | 4 | 0 | |u http://dx.doi.org/10.1007/s00216-023-05013-x |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 416 |j 2024 |e 1 |b 01 |c 01 |h 255-264 |