Influence of taping on force sense accuracy : a systematic review with between and within group meta-analysis
© 2023. BioMed Central Ltd., part of Springer Nature..
Taping is a common technique used to address proprioceptive deficits in both healthy and patient population groups. Although there is increasing interest in taping to address proprioceptive deficits, little is known about its effects on the kinetic aspects of proprioception as measured by force sense accuracy. To address this gap in the literature, the present systematic review and meta-analysis was conducted to evaluate the impact of taping on force sense accuracy. A search for relevant literature was conducted following PRISMA guidelines across seven databases and one register. Eleven studies with 279 participants were included in the review out of 7362 records. In the between-group analyses, we found a significant improvement in absolute (p < 0.01) and relative (p = 0.01) force sense accuracy with taping compared to no comparator. Likewise, a significant improvement in absolute (p = 0.01) force sense accuracy was also observed with taping compared to placebo tape. In the within group analysis, this reduction in the absolute (p = 0.11) force sense accuracy was not significant. Additional exploratory subgroup analyses revealed between group improvement in force sense accuracy in both healthy individuals and individuals affected by medial epicondylitis. The findings of this meta-analysis should be interpreted with caution due to the limited number of studies and a lack of blinded randomized controlled trials, which may impact the generalizability of the results. More high-quality research is needed to confirm the overall effect of taping on force sense accuracy.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:15 |
---|---|
Enthalten in: |
BMC sports science, medicine & rehabilitation - 15(2023), 1 vom: 20. Okt., Seite 138 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Ghai, Shashank [VerfasserIn] |
---|
Links: |
---|
Themen: |
Force sense error |
---|
Anmerkungen: |
Date Revised 23.11.2023 published: Electronic Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.1186/s13102-023-00740-1 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM363566023 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM363566023 | ||
003 | DE-627 | ||
005 | 20231226093622.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1186/s13102-023-00740-1 |2 doi | |
028 | 5 | 2 | |a pubmed24n1211.xml |
035 | |a (DE-627)NLM363566023 | ||
035 | |a (NLM)37864268 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Ghai, Shashank |e verfasserin |4 aut | |
245 | 1 | 0 | |a Influence of taping on force sense accuracy |b a systematic review with between and within group meta-analysis |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 23.11.2023 | ||
500 | |a published: Electronic | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a © 2023. BioMed Central Ltd., part of Springer Nature. | ||
520 | |a Taping is a common technique used to address proprioceptive deficits in both healthy and patient population groups. Although there is increasing interest in taping to address proprioceptive deficits, little is known about its effects on the kinetic aspects of proprioception as measured by force sense accuracy. To address this gap in the literature, the present systematic review and meta-analysis was conducted to evaluate the impact of taping on force sense accuracy. A search for relevant literature was conducted following PRISMA guidelines across seven databases and one register. Eleven studies with 279 participants were included in the review out of 7362 records. In the between-group analyses, we found a significant improvement in absolute (p < 0.01) and relative (p = 0.01) force sense accuracy with taping compared to no comparator. Likewise, a significant improvement in absolute (p = 0.01) force sense accuracy was also observed with taping compared to placebo tape. In the within group analysis, this reduction in the absolute (p = 0.11) force sense accuracy was not significant. Additional exploratory subgroup analyses revealed between group improvement in force sense accuracy in both healthy individuals and individuals affected by medial epicondylitis. The findings of this meta-analysis should be interpreted with caution due to the limited number of studies and a lack of blinded randomized controlled trials, which may impact the generalizability of the results. More high-quality research is needed to confirm the overall effect of taping on force sense accuracy | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Force sense error | |
650 | 4 | |a Kinetics | |
650 | 4 | |a Sensorimotor learning | |
650 | 4 | |a Tactile stimulation | |
650 | 4 | |a Taping | |
700 | 1 | |a Ghai, Ishan |e verfasserin |4 aut | |
700 | 1 | |a Narciss, Susanne |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t BMC sports science, medicine & rehabilitation |d 2013 |g 15(2023), 1 vom: 20. Okt., Seite 138 |w (DE-627)NLM22639803X |x 2052-1847 |7 nnns |
773 | 1 | 8 | |g volume:15 |g year:2023 |g number:1 |g day:20 |g month:10 |g pages:138 |
856 | 4 | 0 | |u http://dx.doi.org/10.1186/s13102-023-00740-1 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 15 |j 2023 |e 1 |b 20 |c 10 |h 138 |