Temporal Stability of Ciliary Beating Post Nasal Brushing, Modulated by Storage Temperature
Primary ciliary dyskinesia is a heterogeneous, inherited motile ciliopathy in which respiratory cilia beat abnormally, and some ultrastructural ciliary defects and specific genetic mutations have been associated with particular ciliary beating alterations. Ciliary beating can be evaluated using digital high-speed videomicroscopy (DHSV). However, normal reference values, essential to assess ciliary beating in patients referred for a PCD diagnostic, vary between centres, as minor variations in protocols might influence ciliary beating. Consequently, establishment of normal values is essential for each PCD diagnostic centre. We aimed to evaluate whether delay after sampling, and temperature for conservation of respiratory ciliated samples, might modify assessments of ciliary beating. In total, 37 healthy nasal brushing samples of respiratory ciliated epithelia were collected. Video sequences were recorded at 37 °C immediately using DHSV. Then, the samples were divided and conserved at 4 °C or at room temperature (RT). Ciliated beating edges were then recorded at 37 °C, at 3 h and at 9 h post sampling. In six samples, recordings were continued up to 72 h after sampling. Ciliary beating was assessed manually by ciliary beat frequency (CBFM) and ciliary beat pattern (CBP). A semi-automatic software was used for quantitative analysis. Both CBF and CBP evaluated manually and by a semi-automated method were stable 9 h after sampling. CBFM was higher when evaluated using samples stored at RT than at 4 °C. CBP and the semi-automated evaluation of ciliary beating were not affected by storage temperature. When establishing normal references values, ciliary beating can be evaluated at 37 °C up to 9 h after nasal brushing, but the storage temperature modifies ciliary beating and needs to be controlled.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:13 |
---|---|
Enthalten in: |
Diagnostics (Basel, Switzerland) - 13(2023), 18 vom: 18. Sept. |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Bricmont, Noemie [VerfasserIn] |
---|
Links: |
---|
Themen: |
Cilia |
---|
Anmerkungen: |
Date Revised 03.10.2023 published: Electronic Citation Status Publisher |
---|
doi: |
10.3390/diagnostics13182974 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM362576092 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM362576092 | ||
003 | DE-627 | ||
005 | 20231226091527.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.3390/diagnostics13182974 |2 doi | |
028 | 5 | 2 | |a pubmed24n1208.xml |
035 | |a (DE-627)NLM362576092 | ||
035 | |a (NLM)37761341 | ||
035 | |a (PII)2974 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Bricmont, Noemie |e verfasserin |4 aut | |
245 | 1 | 0 | |a Temporal Stability of Ciliary Beating Post Nasal Brushing, Modulated by Storage Temperature |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 03.10.2023 | ||
500 | |a published: Electronic | ||
500 | |a Citation Status Publisher | ||
520 | |a Primary ciliary dyskinesia is a heterogeneous, inherited motile ciliopathy in which respiratory cilia beat abnormally, and some ultrastructural ciliary defects and specific genetic mutations have been associated with particular ciliary beating alterations. Ciliary beating can be evaluated using digital high-speed videomicroscopy (DHSV). However, normal reference values, essential to assess ciliary beating in patients referred for a PCD diagnostic, vary between centres, as minor variations in protocols might influence ciliary beating. Consequently, establishment of normal values is essential for each PCD diagnostic centre. We aimed to evaluate whether delay after sampling, and temperature for conservation of respiratory ciliated samples, might modify assessments of ciliary beating. In total, 37 healthy nasal brushing samples of respiratory ciliated epithelia were collected. Video sequences were recorded at 37 °C immediately using DHSV. Then, the samples were divided and conserved at 4 °C or at room temperature (RT). Ciliated beating edges were then recorded at 37 °C, at 3 h and at 9 h post sampling. In six samples, recordings were continued up to 72 h after sampling. Ciliary beating was assessed manually by ciliary beat frequency (CBFM) and ciliary beat pattern (CBP). A semi-automatic software was used for quantitative analysis. Both CBF and CBP evaluated manually and by a semi-automated method were stable 9 h after sampling. CBFM was higher when evaluated using samples stored at RT than at 4 °C. CBP and the semi-automated evaluation of ciliary beating were not affected by storage temperature. When establishing normal references values, ciliary beating can be evaluated at 37 °C up to 9 h after nasal brushing, but the storage temperature modifies ciliary beating and needs to be controlled | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a cilia | |
650 | 4 | |a ciliary beating | |
650 | 4 | |a ciliary videomicroscopy | |
650 | 4 | |a primary ciliary dyskinesia | |
700 | 1 | |a Bonhiver, Romane |e verfasserin |4 aut | |
700 | 1 | |a Benchimol, Lionel |e verfasserin |4 aut | |
700 | 1 | |a Louis, Bruno |e verfasserin |4 aut | |
700 | 1 | |a Papon, Jean-François |e verfasserin |4 aut | |
700 | 1 | |a Monseur, Justine |e verfasserin |4 aut | |
700 | 1 | |a Donneau, Anne-Françoise |e verfasserin |4 aut | |
700 | 1 | |a Moermans, Catherine |e verfasserin |4 aut | |
700 | 1 | |a Schleich, Florence |e verfasserin |4 aut | |
700 | 1 | |a Calmès, Doriane |e verfasserin |4 aut | |
700 | 1 | |a Poirrier, Anne-Lise |e verfasserin |4 aut | |
700 | 1 | |a Louis, Renaud |e verfasserin |4 aut | |
700 | 1 | |a Seghaye, Marie-Christine |e verfasserin |4 aut | |
700 | 1 | |a Kempeneers, Céline |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Diagnostics (Basel, Switzerland) |d 2011 |g 13(2023), 18 vom: 18. Sept. |w (DE-627)NLM250111136 |x 2075-4418 |7 nnns |
773 | 1 | 8 | |g volume:13 |g year:2023 |g number:18 |g day:18 |g month:09 |
856 | 4 | 0 | |u http://dx.doi.org/10.3390/diagnostics13182974 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 13 |j 2023 |e 18 |b 18 |c 09 |