The consistency of skeletal muscle mass measured by CT at L1 and L3 levels and the correlation of skeletal muscle density at L1 level with prognosis in dialysis patients

Objective: To investigate the consistency of skeletal muscle mass by CT at 1st lumbar vertebrae (L1) and 3rd lumbar vertebrae (L3) levels and the correlation of skeletal muscle density (SMD) at L1 level with prognosis in dialysis patients. Methods: A total of 1 020 patients who underwent initial dialysis and had CT examination data in four centers (Zhongda Hospital Affiliated to Southeast University, the Third Affiliated Hospital of Soochow University, Taizhou People's Hospital Affiliated to Nanjing Medical University and the Affiliated Hospital of Yangzhou University) from January 2014 to December 2019 were retrospectively collected. The skeletal muscle index (SMI) and SMD at L1 and L3 CT images were measured and calculated in patients with both L1 and L3 level CT images. The consistency of SMI and SMD at L1 and L3 levels was analyzed, and the cut-off value of SMI and SMD at L1 level for predicting all-cause mortality and their correlation with the prognosis of dialysis patients were studied. Cox regression model was used to analyze the risk factors for all-cause death and cardiac death. Results: A total of 383 patients had both L1 and L3 level images, including 233 males and 150 females. The average SMD value of 16 samples (4.2%) exceeded the 95% consistency limit range (-8.71 to 7.75 HU), and the average SMI value of 15 samples (3.9%) exceeded the 95% consistency limit range (-20.45 to 9.53 HU). The optimal cut-off value of SMD at L1 level for predicting all-cause mortality was 36.46 HU and the area under curve (AUC) of receiver operating characteristic (ROC) curve was 0.658 (95%CI: 0.596-0.721, P<0.001), with the sensitivity and specificity of 83.8% and 57.5%, respectively. SMI at L1 level was not significantly associated with all-cause mortality (P=0.299). Multivariate Cox regression analysis showed that low SMD at L1 level was associated with all-cause mortality (HR=2.861, 95%CI: 1.576-5.193, P=0.001) and cardiac death (HR=3.771, 95%CI:1.462-9.724, P=0.006). Conclusions: SMD at L1 levelis consistent with SMD at L3 level and can be used to evaluate muscle mass. Low SMD is a risk factor for mortality in dialysis patients.

Medienart:

E-Artikel

Erscheinungsjahr:

2023

Erschienen:

2023

Enthalten in:

Zur Gesamtaufnahme - volume:103

Enthalten in:

Zhonghua yi xue za zhi - 103(2023), 36 vom: 26. Sept., Seite 2850-2858

Sprache:

Chinesisch

Beteiligte Personen:

Yang, M [VerfasserIn]
Hou, S M [VerfasserIn]
Yuan, L [VerfasserIn]
Wang, M [VerfasserIn]
Zheng, J [VerfasserIn]
Lu, K Q [VerfasserIn]
Yan, Y [VerfasserIn]
Zhang, S Y [VerfasserIn]
Li, M [VerfasserIn]
Cao, J Y [VerfasserIn]
Yang, M [VerfasserIn]
Zhang, X L [VerfasserIn]
Liu, H [VerfasserIn]
Liu, B C [VerfasserIn]
Wang, Y [VerfasserIn]
Wang, B [VerfasserIn]

Links:

Volltext

Themen:

English Abstract
Journal Article

Anmerkungen:

Date Completed 21.09.2023

Date Revised 21.09.2023

published: Print

Citation Status MEDLINE

doi:

10.3760/cma.j.cn112137-20230608-00970

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

NLM362237972