Use of a flexible tip bougie (FlexTip) in the management of the first-attempt failure intubation with the C-MAC D-Blade videolaryngoscope in the intensive care unit : A prospective, case series
Copyright © 2023 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved..
We describe a series of 11 cases in which we used the new flexible tip (FlexTip) bougie as a rescue device following first-attempt failure at intubation with the C-MAC D-Blade video laryngoscope in our UCI. We collected data from all intubations performed using the C-MAC D-Blade video laryngoscope over a 16-month period. Ninety six patients were included in the study: 79 (86.8%) were intubated at the first attempt; 11 (12.1%) required 2 attempts; and 1 patient required 3 attempts. The Frova Intubating Introducer was used in 1 of the 12 patients requiring more than 1 intubation attempt, and the FlexTip was used in the remaining 11. This study shows that the new FlexTip bougie is a good rescue device when the first attempt at video laryngoscope intubation fails.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:71 |
---|---|
Enthalten in: |
Revista espanola de anestesiologia y reanimacion - 71(2024), 1 vom: 04. Jan., Seite 58-63 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Taboada, M [VerfasserIn] |
---|
Links: |
---|
Themen: |
Airway management |
---|
Anmerkungen: |
Date Completed 07.02.2024 Date Revised 07.02.2024 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.redare.2023.02.006 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM361641567 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM361641567 | ||
003 | DE-627 | ||
005 | 20240207232036.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.redare.2023.02.006 |2 doi | |
028 | 5 | 2 | |a pubmed24n1283.xml |
035 | |a (DE-627)NLM361641567 | ||
035 | |a (NLM)37666451 | ||
035 | |a (PII)S2341-1929(23)00137-3 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Taboada, M |e verfasserin |4 aut | |
245 | 1 | 0 | |a Use of a flexible tip bougie (FlexTip) in the management of the first-attempt failure intubation with the C-MAC D-Blade videolaryngoscope in the intensive care unit |b A prospective, case series |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 07.02.2024 | ||
500 | |a Date Revised 07.02.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2023 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved. | ||
520 | |a We describe a series of 11 cases in which we used the new flexible tip (FlexTip) bougie as a rescue device following first-attempt failure at intubation with the C-MAC D-Blade video laryngoscope in our UCI. We collected data from all intubations performed using the C-MAC D-Blade video laryngoscope over a 16-month period. Ninety six patients were included in the study: 79 (86.8%) were intubated at the first attempt; 11 (12.1%) required 2 attempts; and 1 patient required 3 attempts. The Frova Intubating Introducer was used in 1 of the 12 patients requiring more than 1 intubation attempt, and the FlexTip was used in the remaining 11. This study shows that the new FlexTip bougie is a good rescue device when the first attempt at video laryngoscope intubation fails | ||
650 | 4 | |a Case Reports | |
650 | 4 | |a Airway management | |
650 | 4 | |a Cuidados intensivos | |
650 | 4 | |a Difficult intubation | |
650 | 4 | |a Intensive care | |
650 | 4 | |a Intubación | |
650 | 4 | |a Intubación difícil | |
650 | 4 | |a Intubation | |
650 | 4 | |a Manejo de la vía aérea | |
700 | 1 | |a Cariñena, A |e verfasserin |4 aut | |
700 | 1 | |a Regueira, J |e verfasserin |4 aut | |
700 | 1 | |a Francisco, C |e verfasserin |4 aut | |
700 | 1 | |a Rodríguez, M |e verfasserin |4 aut | |
700 | 1 | |a Seoane-Pillado, T |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Revista espanola de anestesiologia y reanimacion |d 2012 |g 71(2024), 1 vom: 04. Jan., Seite 58-63 |w (DE-627)NLM222859482 |x 2341-1929 |7 nnns |
773 | 1 | 8 | |g volume:71 |g year:2024 |g number:1 |g day:04 |g month:01 |g pages:58-63 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.redare.2023.02.006 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 71 |j 2024 |e 1 |b 04 |c 01 |h 58-63 |