Repeated deep-inspiration breath-hold CT scans at planning underestimate the actual motion between breath-holds at treatment for lung cancer and lymphoma patients
Copyright © 2023 Elsevier B.V. All rights reserved..
PURPOSE/OBJECTIVE: Deep-inspiration breath-hold (DIBH) during radiotherapy may reduce dose to the lungs and heart compared to treatment in free breathing. However, intra-fractional target shifts between several breath-holds may decrease target coverage. We compared target shifts between four DIBHs at the planning-CT session with those measured on CBCT-scans obtained pre- and post-DIBH treatments.
MATERIAL/METHODS: Twenty-nine lung cancer and nine lymphoma patients were treated in DIBH. An external gating block was used as surrogate for the DIBH-level with a window of 2 mm. Four DIBH CT-scans were acquired: one for planning (CTDIBH3) and three additional (CTDIBH1,2,4) to assess the intra-DIBH target shifts at scanning by registration to CTDIBH3. During treatment, pre-treatment (CBCTpre) and post-treatment (CBCTpost) scans were acquired. For each pair of CBCTpre/post, the target intra-DIBH shift was determined. For lung cancer, tumour (GTV-Tlung) and lymph nodes (GTV-Nlung) were analysed separately. Group mean (GM), systematic and random errors, and GM for the absolute maximum shifts (GMmax) were calculated for the shifts between CTDIBH1,2,3,4 and between CBCTpre/post.
RESULTS: For GTV-Tlung, GMmax was larger at CBCT than CT in all directions. GMmax in cranio-caudal direction was 3.3 mm (CT)and 6.1 mm (CBCT). The standard deviations of the shifts in the left-right and cranio-caudal directions were larger at CBCT than CT. For GTV-Nlung and CTVlymphoma, no difference was found in GMmax or SD.
CONCLUSION: Intra-DIBH shifts at planning-CT session are generally smaller than intra-DIBH shifts observed at CBCTpre/post and therefore underestimate the intra-fractional DIBH uncertainty during treatment. Lung tumours show larger intra-fractional variations than lymph nodes and lymphoma targets.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:188 |
---|---|
Enthalten in: |
Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology - 188(2023) vom: 15. Nov., Seite 109887 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Hoffmann, Lone [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Revised 22.10.2023 published: Print-Electronic Citation Status Publisher |
---|
doi: |
10.1016/j.radonc.2023.109887 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM361573995 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM361573995 | ||
003 | DE-627 | ||
005 | 20231226085430.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.radonc.2023.109887 |2 doi | |
028 | 5 | 2 | |a pubmed24n1205.xml |
035 | |a (DE-627)NLM361573995 | ||
035 | |a (NLM)37659663 | ||
035 | |a (PII)S0167-8140(23)89781-X | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Hoffmann, Lone |e verfasserin |4 aut | |
245 | 1 | 0 | |a Repeated deep-inspiration breath-hold CT scans at planning underestimate the actual motion between breath-holds at treatment for lung cancer and lymphoma patients |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 22.10.2023 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status Publisher | ||
520 | |a Copyright © 2023 Elsevier B.V. All rights reserved. | ||
520 | |a PURPOSE/OBJECTIVE: Deep-inspiration breath-hold (DIBH) during radiotherapy may reduce dose to the lungs and heart compared to treatment in free breathing. However, intra-fractional target shifts between several breath-holds may decrease target coverage. We compared target shifts between four DIBHs at the planning-CT session with those measured on CBCT-scans obtained pre- and post-DIBH treatments | ||
520 | |a MATERIAL/METHODS: Twenty-nine lung cancer and nine lymphoma patients were treated in DIBH. An external gating block was used as surrogate for the DIBH-level with a window of 2 mm. Four DIBH CT-scans were acquired: one for planning (CTDIBH3) and three additional (CTDIBH1,2,4) to assess the intra-DIBH target shifts at scanning by registration to CTDIBH3. During treatment, pre-treatment (CBCTpre) and post-treatment (CBCTpost) scans were acquired. For each pair of CBCTpre/post, the target intra-DIBH shift was determined. For lung cancer, tumour (GTV-Tlung) and lymph nodes (GTV-Nlung) were analysed separately. Group mean (GM), systematic and random errors, and GM for the absolute maximum shifts (GMmax) were calculated for the shifts between CTDIBH1,2,3,4 and between CBCTpre/post | ||
520 | |a RESULTS: For GTV-Tlung, GMmax was larger at CBCT than CT in all directions. GMmax in cranio-caudal direction was 3.3 mm (CT)and 6.1 mm (CBCT). The standard deviations of the shifts in the left-right and cranio-caudal directions were larger at CBCT than CT. For GTV-Nlung and CTVlymphoma, no difference was found in GMmax or SD | ||
520 | |a CONCLUSION: Intra-DIBH shifts at planning-CT session are generally smaller than intra-DIBH shifts observed at CBCTpre/post and therefore underestimate the intra-fractional DIBH uncertainty during treatment. Lung tumours show larger intra-fractional variations than lymph nodes and lymphoma targets | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a DIBH | |
650 | 4 | |a Intra-fraction | |
650 | 4 | |a Lung cancer | |
650 | 4 | |a Lymphoma | |
700 | 1 | |a Ehmsen, M L |e verfasserin |4 aut | |
700 | 1 | |a Hansen, J |e verfasserin |4 aut | |
700 | 1 | |a Hansen, R |e verfasserin |4 aut | |
700 | 1 | |a Knap, M M |e verfasserin |4 aut | |
700 | 1 | |a Mortensen, H R |e verfasserin |4 aut | |
700 | 1 | |a Poulsen, P R |e verfasserin |4 aut | |
700 | 1 | |a Ravkilde, T |e verfasserin |4 aut | |
700 | 1 | |a Rose, H K |e verfasserin |4 aut | |
700 | 1 | |a Schmidt, H H |e verfasserin |4 aut | |
700 | 1 | |a Worm, E S |e verfasserin |4 aut | |
700 | 1 | |a Møller, D S |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology |d 1993 |g 188(2023) vom: 15. Nov., Seite 109887 |w (DE-627)NLM012598305 |x 1879-0887 |7 nnns |
773 | 1 | 8 | |g volume:188 |g year:2023 |g day:15 |g month:11 |g pages:109887 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.radonc.2023.109887 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 188 |j 2023 |b 15 |c 11 |h 109887 |