Dual-energy CT-based radiomics for predicting invasiveness of lung adenocarcinoma appearing as ground-glass nodules
Copyright © 2023 Zheng, Han, Jia, Ding, Zhang, Li, Cao, Zhang, Zhang and Shi..
Objectives: To explore the value of radiomics based on Dual-energy CT (DECT) for discriminating preinvasive or MIA from IA appearing as GGNs before surgery.
Methods: The retrospective study included 92 patients with lung adenocarcinoma comprising 30 IA and 62 preinvasive-MIA, which were further divided into a training (n=64) and a test set (n=28). Clinical and radiographic features along with quantitative parameters were recorded. Radiomics features were derived from virtual monoenergetic images (VMI), including 50kev and 150kev images. Intraclass correlation coefficients (ICCs), Pearson's correlation analysis and least absolute shrinkage and selection operator (LASSO) penalized logistic regression were conducted to eliminate unstable and redundant features. The performance of the models was evaluated by area under the curve (AUC) and the clinical utility was assessed using decision curve analysis (DCA).
Results: The DECT-based radiomics model performed well with an AUC of 0.957 and 0.865 in the training and test set. The clinical-DECT model, comprising sex, age, tumor size, density, smoking, alcohol, effective atomic number, and normalized iodine concentration, had an AUC of 0.929 in the training and 0.719 in the test set. In addition, the radiomics model revealed a higher AUC value and a greater net benefit to patients than the clinical-DECT model.
Conclusion: DECT-based radiomics features were valuable in predicting the invasiveness of GGNs, yielding a better predictive performance than the clinical-DECT model.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:13 |
---|---|
Enthalten in: |
Frontiers in oncology - 13(2023) vom: 22., Seite 1208758 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Zheng, Yuting [VerfasserIn] |
---|
Links: |
---|
Themen: |
Dual-energy spectral computed tomography |
---|
Anmerkungen: |
Date Revised 29.08.2023 published: Electronic-eCollection Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.3389/fonc.2023.1208758 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM361351755 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM361351755 | ||
003 | DE-627 | ||
005 | 20231226210823.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.3389/fonc.2023.1208758 |2 doi | |
028 | 5 | 2 | |a pubmed24n1204.xml |
035 | |a (DE-627)NLM361351755 | ||
035 | |a (NLM)37637058 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Zheng, Yuting |e verfasserin |4 aut | |
245 | 1 | 0 | |a Dual-energy CT-based radiomics for predicting invasiveness of lung adenocarcinoma appearing as ground-glass nodules |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 29.08.2023 | ||
500 | |a published: Electronic-eCollection | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a Copyright © 2023 Zheng, Han, Jia, Ding, Zhang, Li, Cao, Zhang, Zhang and Shi. | ||
520 | |a Objectives: To explore the value of radiomics based on Dual-energy CT (DECT) for discriminating preinvasive or MIA from IA appearing as GGNs before surgery | ||
520 | |a Methods: The retrospective study included 92 patients with lung adenocarcinoma comprising 30 IA and 62 preinvasive-MIA, which were further divided into a training (n=64) and a test set (n=28). Clinical and radiographic features along with quantitative parameters were recorded. Radiomics features were derived from virtual monoenergetic images (VMI), including 50kev and 150kev images. Intraclass correlation coefficients (ICCs), Pearson's correlation analysis and least absolute shrinkage and selection operator (LASSO) penalized logistic regression were conducted to eliminate unstable and redundant features. The performance of the models was evaluated by area under the curve (AUC) and the clinical utility was assessed using decision curve analysis (DCA) | ||
520 | |a Results: The DECT-based radiomics model performed well with an AUC of 0.957 and 0.865 in the training and test set. The clinical-DECT model, comprising sex, age, tumor size, density, smoking, alcohol, effective atomic number, and normalized iodine concentration, had an AUC of 0.929 in the training and 0.719 in the test set. In addition, the radiomics model revealed a higher AUC value and a greater net benefit to patients than the clinical-DECT model | ||
520 | |a Conclusion: DECT-based radiomics features were valuable in predicting the invasiveness of GGNs, yielding a better predictive performance than the clinical-DECT model | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a dual-energy spectral computed tomography | |
650 | 4 | |a ground-glass nodules | |
650 | 4 | |a invasion | |
650 | 4 | |a lung adenocarcinoma | |
650 | 4 | |a prediction | |
650 | 4 | |a radiomics | |
700 | 1 | |a Han, Xiaoyu |e verfasserin |4 aut | |
700 | 1 | |a Jia, Xi |e verfasserin |4 aut | |
700 | 1 | |a Ding, Chengyu |e verfasserin |4 aut | |
700 | 1 | |a Zhang, Kailu |e verfasserin |4 aut | |
700 | 1 | |a Li, Hanting |e verfasserin |4 aut | |
700 | 1 | |a Cao, Xuexiang |e verfasserin |4 aut | |
700 | 1 | |a Zhang, Xiaohui |e verfasserin |4 aut | |
700 | 1 | |a Zhang, Xin |e verfasserin |4 aut | |
700 | 1 | |a Shi, Heshui |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Frontiers in oncology |d 2011 |g 13(2023) vom: 22., Seite 1208758 |w (DE-627)NLM218189583 |x 2234-943X |7 nnns |
773 | 1 | 8 | |g volume:13 |g year:2023 |g day:22 |g pages:1208758 |
856 | 4 | 0 | |u http://dx.doi.org/10.3389/fonc.2023.1208758 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 13 |j 2023 |b 22 |h 1208758 |