Modified Technique to Rehabilitate American Society of Anesthesiology-III Patient, Through Flapless Procedure With Computed Tomography-Guided Surgery
Copyright © 2023 by Mutaz B. Habal, MD..
PURPOSE: The aim was to evaluate the safety and effectiveness of a computed tomography-guided surgery implant placement with a flapless technique and immediate functional loading in an American Society of Anesthesiology-III patient.
METHODS: This technical note involved a 64-year-old American Society of Anesthesiology-III patient. Her hopeless teeth were extracted and a restorative evaluation was provided as a prosthetic reference. The surgical procedure was based on the flapless technique that let us to use local anesthesia. The authors used an All-on-4 concept restoration for maxilla and conventional fixed prosthesis procedures for jaw rehabilitation. The authors placed 4 tilted implants in the upper maxilla and 6 right implants in the jaw. Implants were loaded with a provisional prosthesis on the same day of surgery. Five months later, provisional restoration was removed; the authors placed into the ceramic crowns 2 Procera Implant Bridge (Nobel Biocare) frameworks, developed through computer-aided design/computer-aided manufacturing technology.
CONCLUSIONS: Computed tomography-guided surgery is a minimally invasive technique that allows, through a flapless approach, safer and more predictable procedures. In this technical note, the authors achieved accurate implant placement and precise fit of restoration with natural looking appearance; this patient-oriented-treatment led to a reduced healing time with better compliance.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:35 |
---|---|
Enthalten in: |
The Journal of craniofacial surgery - 35(2024), 1 vom: 01. Jan., Seite e8-e11 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Franco, Rocco [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 01.02.2024 Date Revised 01.02.2024 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1097/SCS.0000000000009607 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM36108448X |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM36108448X | ||
003 | DE-627 | ||
005 | 20240201231924.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1097/SCS.0000000000009607 |2 doi | |
028 | 5 | 2 | |a pubmed24n1277.xml |
035 | |a (DE-627)NLM36108448X | ||
035 | |a (NLM)37609997 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Franco, Rocco |e verfasserin |4 aut | |
245 | 1 | 0 | |a Modified Technique to Rehabilitate American Society of Anesthesiology-III Patient, Through Flapless Procedure With Computed Tomography-Guided Surgery |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 01.02.2024 | ||
500 | |a Date Revised 01.02.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2023 by Mutaz B. Habal, MD. | ||
520 | |a PURPOSE: The aim was to evaluate the safety and effectiveness of a computed tomography-guided surgery implant placement with a flapless technique and immediate functional loading in an American Society of Anesthesiology-III patient | ||
520 | |a METHODS: This technical note involved a 64-year-old American Society of Anesthesiology-III patient. Her hopeless teeth were extracted and a restorative evaluation was provided as a prosthetic reference. The surgical procedure was based on the flapless technique that let us to use local anesthesia. The authors used an All-on-4 concept restoration for maxilla and conventional fixed prosthesis procedures for jaw rehabilitation. The authors placed 4 tilted implants in the upper maxilla and 6 right implants in the jaw. Implants were loaded with a provisional prosthesis on the same day of surgery. Five months later, provisional restoration was removed; the authors placed into the ceramic crowns 2 Procera Implant Bridge (Nobel Biocare) frameworks, developed through computer-aided design/computer-aided manufacturing technology | ||
520 | |a CONCLUSIONS: Computed tomography-guided surgery is a minimally invasive technique that allows, through a flapless approach, safer and more predictable procedures. In this technical note, the authors achieved accurate implant placement and precise fit of restoration with natural looking appearance; this patient-oriented-treatment led to a reduced healing time with better compliance | ||
650 | 4 | |a Journal Article | |
650 | 7 | |a Dental Implants |2 NLM | |
700 | 1 | |a Ferrari, Giulia |e verfasserin |4 aut | |
700 | 1 | |a Vazzana, Giuseppe |e verfasserin |4 aut | |
700 | 1 | |a Cicciù, Marco |e verfasserin |4 aut | |
700 | 1 | |a Minervini, Giuseppe |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t The Journal of craniofacial surgery |d 1995 |g 35(2024), 1 vom: 01. Jan., Seite e8-e11 |w (DE-627)NLM012715700 |x 1536-3732 |7 nnns |
773 | 1 | 8 | |g volume:35 |g year:2024 |g number:1 |g day:01 |g month:01 |g pages:e8-e11 |
856 | 4 | 0 | |u http://dx.doi.org/10.1097/SCS.0000000000009607 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 35 |j 2024 |e 1 |b 01 |c 01 |h e8-e11 |