Quantification of GS-441524 concentration in feline plasma using high performance liquid chromatography with fluorescence detection
The adenosine analogue GS-441524 has demonstrated efficacy in treatment of feline infectious peritonitis (FIP). With no commercially registered formulations of GS-441524 available, global focus shifted to its pro-drug remdesivir, as it became more accessible throughout the COVID-19 pandemic. This study developed and validated a simple liquid chromatography equipped with a fluorescence detector to quantify plasma concentrations of GS-441524 applicable for routine therapeutic monitoring of remdesivir or GS-441524 therapy for FIP infected cats. A Waters X-Bridge C18, 5 µm, 150 × 4.6 mm, column was used and mixtures of 20 mM ammonium acetate (pH 4.5) with acetonitrile of 5% and 70% were prepared for gradient mobile phase. With a simple protein precipitation using methanol to clean plasma sample, GS-441524 was monitored at excitation and emission wavelengths of 250 nm and 475 nm, respectively. Using an external standard, the lowest and highest limits of quantification were 19.5 ng/mL to 10,000 ng/mL, respectively. The intra- and inter day trueness of the quality controls (QCs) were within 10% of their nominal concentrations and intra- and inter day precision of the QCs (expressed as the coefficient of variation) ranged from 1.7 to 5.7%, This assay was able to quantify plasma trough levels of GS-441524 (23.7-190.1 ng/mL) after the administration of remdesivir (9.9-15.0 mg/kg BW, IV or SC) in FIP cats (n = 12). Accordingly, this study generated an alternative and cost-effective way to quantify GS-441524 in feline biological fluids at least up to 24 hr after administrations of remdesivir.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:43 |
---|---|
Enthalten in: |
The veterinary quarterly - 43(2023), 1 vom: 09. Dez., Seite 1-9 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Kimble, Benjamin [VerfasserIn] |
---|
Links: |
---|
Themen: |
1BQK176DT6 |
---|
Anmerkungen: |
Date Completed 18.08.2023 Date Revised 23.08.2023 published: Print Citation Status MEDLINE |
---|
doi: |
10.1080/01652176.2023.2246553 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM360563414 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM360563414 | ||
003 | DE-627 | ||
005 | 20231226083258.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1080/01652176.2023.2246553 |2 doi | |
028 | 5 | 2 | |a pubmed24n1201.xml |
035 | |a (DE-627)NLM360563414 | ||
035 | |a (NLM)37556736 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Kimble, Benjamin |e verfasserin |4 aut | |
245 | 1 | 0 | |a Quantification of GS-441524 concentration in feline plasma using high performance liquid chromatography with fluorescence detection |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 18.08.2023 | ||
500 | |a Date Revised 23.08.2023 | ||
500 | |a published: Print | ||
500 | |a Citation Status MEDLINE | ||
520 | |a The adenosine analogue GS-441524 has demonstrated efficacy in treatment of feline infectious peritonitis (FIP). With no commercially registered formulations of GS-441524 available, global focus shifted to its pro-drug remdesivir, as it became more accessible throughout the COVID-19 pandemic. This study developed and validated a simple liquid chromatography equipped with a fluorescence detector to quantify plasma concentrations of GS-441524 applicable for routine therapeutic monitoring of remdesivir or GS-441524 therapy for FIP infected cats. A Waters X-Bridge C18, 5 µm, 150 × 4.6 mm, column was used and mixtures of 20 mM ammonium acetate (pH 4.5) with acetonitrile of 5% and 70% were prepared for gradient mobile phase. With a simple protein precipitation using methanol to clean plasma sample, GS-441524 was monitored at excitation and emission wavelengths of 250 nm and 475 nm, respectively. Using an external standard, the lowest and highest limits of quantification were 19.5 ng/mL to 10,000 ng/mL, respectively. The intra- and inter day trueness of the quality controls (QCs) were within 10% of their nominal concentrations and intra- and inter day precision of the QCs (expressed as the coefficient of variation) ranged from 1.7 to 5.7%, This assay was able to quantify plasma trough levels of GS-441524 (23.7-190.1 ng/mL) after the administration of remdesivir (9.9-15.0 mg/kg BW, IV or SC) in FIP cats (n = 12). Accordingly, this study generated an alternative and cost-effective way to quantify GS-441524 in feline biological fluids at least up to 24 hr after administrations of remdesivir | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Cat | |
650 | 4 | |a FIP | |
650 | 4 | |a GS-441524 | |
650 | 4 | |a HPLC | |
650 | 4 | |a feline | |
650 | 4 | |a feline infectious peritonitis | |
650 | 4 | |a remdesivir | |
650 | 7 | |a GS-441524 |2 NLM | |
650 | 7 | |a 1BQK176DT6 |2 NLM | |
700 | 1 | |a Coggins, Sally J |e verfasserin |4 aut | |
700 | 1 | |a Norris, Jacqueline M |e verfasserin |4 aut | |
700 | 1 | |a Thompson, Mary F |e verfasserin |4 aut | |
700 | 1 | |a Govendir, Merran |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t The veterinary quarterly |d 1979 |g 43(2023), 1 vom: 09. Dez., Seite 1-9 |w (DE-627)NLM012965510 |x 1875-5941 |7 nnns |
773 | 1 | 8 | |g volume:43 |g year:2023 |g number:1 |g day:09 |g month:12 |g pages:1-9 |
856 | 4 | 0 | |u http://dx.doi.org/10.1080/01652176.2023.2246553 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 43 |j 2023 |e 1 |b 09 |c 12 |h 1-9 |