Real-world evidence for the use of subcutaneous implantable cardioverter-defibrillators in China : A single-center experience
© 2023. The Author(s), under exclusive licence to Springer Medizin Verlag GmbH, ein Teil von Springer Nature..
BACKGROUND: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) have been shown to be non-inferior to transvenous ICDs in the prevention of sudden cardiac death (SCD), but there is still a lack of evidence from clinical trials in China. We investigated whether S‑ICD implantation in the Chinese population is safe and feasible and should be promoted in the future.
METHODS: Consecutive patients undergoing S‑ICD implantation at our center were enrolled in this retrospective study. Data were collected within the median follow-up period of 554 days. Data concerning patient selection, implantation procedures, complications, and episodes of shock were analyzed.
RESULTS: In total, 70.2% of all 47 patients (median age = 39 years) were included for secondary prevention of SCD with different etiologies. Vector screening showed that 98% of patients were with > 1 appropriate vector in all postures. An intraoperative defibrillation test was not performed on six patients because of the high risk of disease deterioration, while all episodes of ventricular fibrillation induced post implantation were terminated by one shock. As expected, no severe complications (e.g., infection and device-related complications) were observed, except for one case of delayed healing of the incision. Overall, 15 patients (31.9%) experienced appropriate shocks (AS) with all episodes terminated by one shock. Two patients (4.3%) experienced inappropriate shocks (IAS) due to noise oversensing, resulting in a high Kaplan-Meier IAS-free rate of 95.7%.
CONCLUSION: Based on appropriate patient selection and standardized implantation procedures, this real-world study confirmed the safety and efficacy of S‑ICD in Chinese patients, indicating that it may help to promote the prevention of SCD in China.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:48 |
---|---|
Enthalten in: |
Herz - 48(2023), 6 vom: 04. Dez., Seite 462-469 |
Sprache: |
Englisch |
---|
Weiterer Titel: |
Praktische Belege für den Einsatz subkutaner implantierbarer Kardioverter-Defibrillatoren in China: Erfahrungen aus einem Einzelzentrum |
---|
Beteiligte Personen: |
Zhang, Lei [VerfasserIn] |
---|
Links: |
---|
Themen: |
Chinese population |
---|
Anmerkungen: |
Date Completed 30.11.2023 Date Revised 30.11.2023 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1007/s00059-023-05192-4 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM360400000 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM360400000 | ||
003 | DE-627 | ||
005 | 20231226082931.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1007/s00059-023-05192-4 |2 doi | |
028 | 5 | 2 | |a pubmed24n1201.xml |
035 | |a (DE-627)NLM360400000 | ||
035 | |a (NLM)37540305 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Zhang, Lei |e verfasserin |4 aut | |
245 | 1 | 0 | |a Real-world evidence for the use of subcutaneous implantable cardioverter-defibrillators in China |b A single-center experience |
246 | 3 | 3 | |a Praktische Belege für den Einsatz subkutaner implantierbarer Kardioverter-Defibrillatoren in China: Erfahrungen aus einem Einzelzentrum |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 30.11.2023 | ||
500 | |a Date Revised 30.11.2023 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2023. The Author(s), under exclusive licence to Springer Medizin Verlag GmbH, ein Teil von Springer Nature. | ||
520 | |a BACKGROUND: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) have been shown to be non-inferior to transvenous ICDs in the prevention of sudden cardiac death (SCD), but there is still a lack of evidence from clinical trials in China. We investigated whether S‑ICD implantation in the Chinese population is safe and feasible and should be promoted in the future | ||
520 | |a METHODS: Consecutive patients undergoing S‑ICD implantation at our center were enrolled in this retrospective study. Data were collected within the median follow-up period of 554 days. Data concerning patient selection, implantation procedures, complications, and episodes of shock were analyzed | ||
520 | |a RESULTS: In total, 70.2% of all 47 patients (median age = 39 years) were included for secondary prevention of SCD with different etiologies. Vector screening showed that 98% of patients were with > 1 appropriate vector in all postures. An intraoperative defibrillation test was not performed on six patients because of the high risk of disease deterioration, while all episodes of ventricular fibrillation induced post implantation were terminated by one shock. As expected, no severe complications (e.g., infection and device-related complications) were observed, except for one case of delayed healing of the incision. Overall, 15 patients (31.9%) experienced appropriate shocks (AS) with all episodes terminated by one shock. Two patients (4.3%) experienced inappropriate shocks (IAS) due to noise oversensing, resulting in a high Kaplan-Meier IAS-free rate of 95.7% | ||
520 | |a CONCLUSION: Based on appropriate patient selection and standardized implantation procedures, this real-world study confirmed the safety and efficacy of S‑ICD in Chinese patients, indicating that it may help to promote the prevention of SCD in China | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Chinese population | |
650 | 4 | |a Efficacy | |
650 | 4 | |a Safety | |
650 | 4 | |a Subcutaneous implantable cardioverter–defibrillator | |
650 | 4 | |a Sudden cardiac death | |
700 | 1 | |a Li, Xiao |e verfasserin |4 aut | |
700 | 1 | |a Liang, Yixiu |e verfasserin |4 aut | |
700 | 1 | |a Wang, Jingfeng |e verfasserin |4 aut | |
700 | 1 | |a Li, Minghui |e verfasserin |4 aut | |
700 | 1 | |a Pan, Lei |e verfasserin |4 aut | |
700 | 1 | |a Chen, Xueying |e verfasserin |4 aut | |
700 | 1 | |a Qin, Shengmei |e verfasserin |4 aut | |
700 | 1 | |a Bai, Jin |e verfasserin |4 aut | |
700 | 1 | |a Wang, Wei |e verfasserin |4 aut | |
700 | 1 | |a Su, Yangang |e verfasserin |4 aut | |
700 | 1 | |a Ge, Junbo |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Herz |d 1993 |g 48(2023), 6 vom: 04. Dez., Seite 462-469 |w (DE-627)NLM000324086 |x 1615-6692 |7 nnns |
773 | 1 | 8 | |g volume:48 |g year:2023 |g number:6 |g day:04 |g month:12 |g pages:462-469 |
856 | 4 | 0 | |u http://dx.doi.org/10.1007/s00059-023-05192-4 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 48 |j 2023 |e 6 |b 04 |c 12 |h 462-469 |