A Fully Automatic Method to Segment Choroid Plexuses in Multiple Sclerosis Using Conventional MRI Sequences

© 2023 The Authors. Journal of Magnetic Resonance Imaging published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine..

BACKGROUND: Choroid plexus (CP) volume has been recently proposed as a proxy for brain neuroinflammation in multiple sclerosis (MS).

PURPOSE: To develop and validate a fast automatic method to segment CP using routinely acquired brain T1-weighted and FLAIR MRI.

STUDY TYPE: Retrospective.

POPULATION: Fifty-five MS patients (33 relapsing-remitting, 22 progressive; mean age = 46.8 ± 10.2 years; 31 women) and 60 healthy controls (HC; mean age = 36.1 ± 12.6 years, 33 women).

FIELD STRENGTH/SEQUENCE: 3D T2-weighted FLAIR and 3D T1-weighted gradient echo sequences at 3.0 T.

ASSESSMENT: Brain tissues were segmented on T1-weighted sequences and a Gaussian Mixture Model (GMM) was fitted to FLAIR image intensities obtained from the ventricle masks of the SIENAX. A second GMM was then applied on the thresholded and filtered ventricle mask. CP volumes were automatically determined and compared with those from manual segmentation by two raters (with 3 and 10 years' experience; reference standard). CP volumes from previously published automatic segmentation methods (freely available Freesurfer [FS] and FS-GMM) were also compared with reference standard. Expanded Disability Status Scale (EDSS) score was assessed within 3 days of MRI. Computational time was assessed for each automatic technique and manual segmentation.

STATISTICAL TESTS: Comparisons of CP volumes with reference standard were evaluated with Bland Altman analysis. Dice similarity coefficients (DSC) were computed to assess automatic CP segmentations. Volume differences between MS and HC for each method were assessed with t-tests and correlations of CP volumes with EDSS were assessed with Pearson's correlation coefficients (R). A P value <0.05 was considered statistically significant.

RESULTS: Compared to manual segmentation, the proposed method had the highest segmentation accuracy (mean DSC = 0.65 ± 0.06) compared to FS (mean DSC = 0.37 ± 0.08) and FS-GMM (0.58 ± 0.06). The percentage CP volume differences relative to manual segmentation were -0.1% ± 0.23, 4.6% ± 2.5, and -0.48% ± 2 for the proposed method, FS, and FS-GMM, respectively. The Pearson's correlations between automatically obtained CP volumes and the manually obtained volumes were 0.70, 0.54, and 0.56 for the proposed method, FS, and FS-GMM, respectively. A significant correlation between CP volume and EDSS was found for the proposed automatic pipeline (R = 0.2), for FS-GMM (R = 0.3) and for manual segmentation (R = 0.4). Computational time for the proposed method (32 ± 2 minutes) was similar to the manual segmentation (20 ± 5 minutes) but <25% of the FS (120 ± 15 minutes) and FS-GMM (125 ± 15 minutes) methods.

DATA CONCLUSION: This study developed an accurate and easily implementable method for automatic CP segmentation in MS using T1-weighted and FLAIR MRI.

EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 4.

Medienart:

E-Artikel

Erscheinungsjahr:

2024

Erschienen:

2024

Enthalten in:

Zur Gesamtaufnahme - volume:59

Enthalten in:

Journal of magnetic resonance imaging : JMRI - 59(2024), 5 vom: 30. Apr., Seite 1643-1652

Sprache:

Englisch

Beteiligte Personen:

Storelli, Loredana [VerfasserIn]
Pagani, Elisabetta [VerfasserIn]
Rubin, Martina [VerfasserIn]
Margoni, Monica [VerfasserIn]
Filippi, Massimo [VerfasserIn]
Rocca, Maria A [VerfasserIn]

Links:

Volltext

Themen:

Automatic segmentation
Choroid plexuses
Inflammation
Journal Article
Multiple sclerosis

Anmerkungen:

Date Completed 08.04.2024

Date Revised 08.04.2024

published: Print-Electronic

Citation Status MEDLINE

doi:

10.1002/jmri.28937

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

NLM360304893