Comprehensive evaluations of a prototype full field-of-view photon counting CT system through phantom studies

© 2023 Institute of Physics and Engineering in Medicine..

Objective. Photon counting CT (PCCT) has been a research focus in the last two decades. Recent studies and advancements have demonstrated that systems using semiconductor-based photon counting detectors (PCDs) have the potential to provide better contrast, noise and spatial resolution performance compared to conventional scintillator-based systems. With multi-energy threshold detection, PCD can simultaneously provide the photon energy measurement and enable material decomposition for spectral imaging. In this work, we report a performance evaluation of our first CdZnTe-based prototype full-size PCCT system through various phantom imaging studies.Approach.This prototype system supports a 500 mm scan field-of-view and 10 mmz-coverage at isocenter. Phantom scans were acquired using 120 kVp from 50 to 400 mAs to assess the imaging performance on: CT number accuracy, uniformity, noise, spatial resolution, material differentiation and quantification.Main results.Both qualitative and quantitative evaluations show that PCCT, under the tested conditions, has superior imaging performance with lower noise and improved spatial resolution compared to conventional energy integrating detector (EID)-CT. Using projection domain material decomposition approach with multiple energy bin measurements, PCCT virtual monoenergetic images have lower noise, and good accuracy in quantifying iodine and calcium concentrations. These results lead to increased contrast-to-noise ratio (CNR) for both high and low contrast study objects compared to EID-CT at matched dose and spatial resolution. PCCT can also generate super-high resolution images using much smaller detector pixel size than EID-CT and greatly improve image spatial resolution.Significance.Improved spatial resolution and quantification accuracy with reduced image noise of the PCCT images can potentially lead to better diagnosis at reduced radiation dose compared to conventional EID-CT. Increased CNR achieved by PCCT suggests potential reduction in iodine contrast media load, resulting in better patient safety and reduced cost.

Medienart:

E-Artikel

Erscheinungsjahr:

2023

Erschienen:

2023

Enthalten in:

Zur Gesamtaufnahme - volume:68

Enthalten in:

Physics in medicine and biology - 68(2023), 17 vom: 14. Aug.

Sprache:

Englisch

Beteiligte Personen:

Zhan, Xiaohui [VerfasserIn]
Zhang, Ruoqiao [VerfasserIn]
Niu, Xiaofeng [VerfasserIn]
Hein, Ilmar [VerfasserIn]
Budden, Brent [VerfasserIn]
Wu, Shuoxing [VerfasserIn]
Markov, Nicolay [VerfasserIn]
Clarke, Cameron [VerfasserIn]
Qiang, Yi [VerfasserIn]
Taguchi, Hiroki [VerfasserIn]
Nomura, Keiichi [VerfasserIn]
Muramatsu, Yoshihisa [VerfasserIn]
Yu, Zhou [VerfasserIn]
Kobayashi, Tatsushi [VerfasserIn]
Thompson, Richard [VerfasserIn]
Miyazaki, Hiroaki [VerfasserIn]
Nakai, Hiroaki [VerfasserIn]

Links:

Volltext

Themen:

9679TC07X4
High resolution
Image quality
Iodine
Journal Article
Photon counting CT
Photon counting detector
Spectral imaging
X-ray computed tomography

Anmerkungen:

Date Completed 15.08.2023

Date Revised 17.08.2023

published: Electronic

Citation Status MEDLINE

doi:

10.1088/1361-6560/acebb3

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

NLM360065988