Diagnostic genosensor for detection of rotavirus based on HFGNs/MXene/PPY signal amplification
© 2023. The Author(s), under exclusive licence to Springer-Verlag GmbH Austria, part of Springer Nature..
A novel genosensor was developed for rotavirus specific cDNA sequence detection. The genosensor was comprised of hierarchical flower-like gold nanostructures, MXene, and polypyrrole (HFGNs/MXene/PPY) nanocomposite as a signal amplification tag, specific antisense ssDNA oligonucleotide as a recognition bioelement, and methylene blue (MB) as a redox marker. The morphological and electrochemical features of the biosensor were first tested and optimized and the high performance of the platform was confirmed in terms of sensitivity and reproducibility. Then, 20 rotavirus RNA isolated from clinical and cell-cultured samples (10 positive and 10 negative confirmed by RT-PCR and electrophoresis methods) were evaluated by the genosensor. The analysis results revealed that the genosensor is able to differentiate successfully between the positive and negative control groups. The developed genosensor for rotavirus RNA detection presented an excellent limit of detection of ∼ 0.8 aM and a determination range of 10-18 and 10-7 M. In addition, the ssDNA/HFGNs/MXene/PPY/GCE showed high selectivity and long-term stability of ~ 24 days. Therefore, this novel genosensor would be of great benefit for the clinical diagnosis of rotavirus.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:190 |
---|---|
Enthalten in: |
Mikrochimica acta - 190(2023), 8 vom: 17. Juli, Seite 293 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Ketabi, Kiana [VerfasserIn] |
---|
Links: |
---|
Anmerkungen: |
Date Completed 19.07.2023 Date Revised 08.08.2023 published: Electronic Citation Status MEDLINE |
---|
doi: |
10.1007/s00604-023-05871-3 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM35959512X |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM35959512X | ||
003 | DE-627 | ||
005 | 20231226081219.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1007/s00604-023-05871-3 |2 doi | |
028 | 5 | 2 | |a pubmed24n1198.xml |
035 | |a (DE-627)NLM35959512X | ||
035 | |a (NLM)37458847 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Ketabi, Kiana |e verfasserin |4 aut | |
245 | 1 | 0 | |a Diagnostic genosensor for detection of rotavirus based on HFGNs/MXene/PPY signal amplification |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 19.07.2023 | ||
500 | |a Date Revised 08.08.2023 | ||
500 | |a published: Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2023. The Author(s), under exclusive licence to Springer-Verlag GmbH Austria, part of Springer Nature. | ||
520 | |a A novel genosensor was developed for rotavirus specific cDNA sequence detection. The genosensor was comprised of hierarchical flower-like gold nanostructures, MXene, and polypyrrole (HFGNs/MXene/PPY) nanocomposite as a signal amplification tag, specific antisense ssDNA oligonucleotide as a recognition bioelement, and methylene blue (MB) as a redox marker. The morphological and electrochemical features of the biosensor were first tested and optimized and the high performance of the platform was confirmed in terms of sensitivity and reproducibility. Then, 20 rotavirus RNA isolated from clinical and cell-cultured samples (10 positive and 10 negative confirmed by RT-PCR and electrophoresis methods) were evaluated by the genosensor. The analysis results revealed that the genosensor is able to differentiate successfully between the positive and negative control groups. The developed genosensor for rotavirus RNA detection presented an excellent limit of detection of ∼ 0.8 aM and a determination range of 10-18 and 10-7 M. In addition, the ssDNA/HFGNs/MXene/PPY/GCE showed high selectivity and long-term stability of ~ 24 days. Therefore, this novel genosensor would be of great benefit for the clinical diagnosis of rotavirus | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Research Support, Non-U.S. Gov't | |
650 | 4 | |a Biosensing techniques | |
650 | 4 | |a DNA biosensor | |
650 | 4 | |a Differential pulse voltammetry | |
650 | 4 | |a Electrochemical genosensor | |
650 | 4 | |a Nanocomposites | |
650 | 4 | |a Virus diagnosis | |
650 | 7 | |a polypyrrole |2 NLM | |
650 | 7 | |a 30604-81-0 |2 NLM | |
650 | 7 | |a Polymers |2 NLM | |
650 | 7 | |a Pyrroles |2 NLM | |
650 | 7 | |a Gold |2 NLM | |
650 | 7 | |a 7440-57-5 |2 NLM | |
650 | 7 | |a MXene |2 NLM | |
650 | 7 | |a DNA, Single-Stranded |2 NLM | |
650 | 7 | |a RNA |2 NLM | |
650 | 7 | |a 63231-63-0 |2 NLM | |
700 | 1 | |a Soleimanjahi, Hoorieh |e verfasserin |4 aut | |
700 | 1 | |a Teimoori, Ali |e verfasserin |4 aut | |
700 | 1 | |a Hatamluyi, Behnaz |e verfasserin |4 aut | |
700 | 1 | |a Rezayi, Majid |e verfasserin |4 aut | |
700 | 1 | |a Meshkat, Zahra |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Mikrochimica acta |d 1994 |g 190(2023), 8 vom: 17. Juli, Seite 293 |w (DE-627)NLM000043036 |x 1436-5073 |7 nnns |
773 | 1 | 8 | |g volume:190 |g year:2023 |g number:8 |g day:17 |g month:07 |g pages:293 |
856 | 4 | 0 | |u http://dx.doi.org/10.1007/s00604-023-05871-3 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 190 |j 2023 |e 8 |b 17 |c 07 |h 293 |