Clinical performance of 0/1 h cardiac troponin algorithm for diagnosing non-STEMI in an emergency setting
Copyright © 2023. Published by Elsevier Inc..
BACKGROUND: Non-ST-segment elevation myocardial infarction (NSTEMI) is a common form of acute myocardial infarction and rapid and accurate diagnosis is crucial for timely treatment. Current guidelines recommend using high-sensitivity cardiac troponin (hs-cTn) assays to determine circulating cTnI or cTnT levels. While the accuracy of the 0 h/1 h algorithm for diagnosing NSTEMI in different regions and patient populations remains controversial. Additionally, point-of-care testing (POCT) cTn assays have the potential to provide troponin readings to physicians within 15 min, but their accuracy in diagnosing NSTEMI in the emergency department (ED) requires further investigation.
METHODS: A single-center prospective observational cohort study was conducted at Shaanxi Provincial People's Hospital to assess the analytical and diagnostic performance of the laboratory-based Roche Modular E170 hs-cTnT using the 0 h/1 h algorithm with Radiometer AQT90-flex POCT cTnT assay in undifferentiated chest pain patients presenting to the ED. Whole-blood samples were collected and hs-cTnT and POCT cTnI were measured simultaneously at baseline and after 1 h.
RESULTS: The study results showed that the POCT cTnT assay using the 0 h/1 h algorithm had comparable diagnostic accuracy to the laboratory-based Roche Modular E170 hs-cTnT assay in diagnosing NSTEMI in patients with chest pain.
CONCLUSION: The laboratory-based Roche Modular E170 hs-cTnT using the 0 h/1 h algorithm is reliable and accurate method for diagnosing NSTEMI in undifferentiated chest pain patients presenting to the ED. POCT cTnT assay has comparable diagnostic accuracy to the hs-cTnT assay and its rapid turnaround time makes it a valuable tool in expediting the diagnostic workup of chest pain patients.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:71 |
---|---|
Enthalten in: |
The American journal of emergency medicine - 71(2023) vom: 15. Sept., Seite 139-143 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Gou, Qiling [VerfasserIn] |
---|
Links: |
---|
Anmerkungen: |
Date Completed 07.08.2023 Date Revised 07.08.2023 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.ajem.2023.06.036 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM358937515 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM358937515 | ||
003 | DE-627 | ||
005 | 20231226075814.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.ajem.2023.06.036 |2 doi | |
028 | 5 | 2 | |a pubmed24n1196.xml |
035 | |a (DE-627)NLM358937515 | ||
035 | |a (NLM)37392513 | ||
035 | |a (PII)S0735-6757(23)00332-7 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Gou, Qiling |e verfasserin |4 aut | |
245 | 1 | 0 | |a Clinical performance of 0/1 h cardiac troponin algorithm for diagnosing non-STEMI in an emergency setting |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 07.08.2023 | ||
500 | |a Date Revised 07.08.2023 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2023. Published by Elsevier Inc. | ||
520 | |a BACKGROUND: Non-ST-segment elevation myocardial infarction (NSTEMI) is a common form of acute myocardial infarction and rapid and accurate diagnosis is crucial for timely treatment. Current guidelines recommend using high-sensitivity cardiac troponin (hs-cTn) assays to determine circulating cTnI or cTnT levels. While the accuracy of the 0 h/1 h algorithm for diagnosing NSTEMI in different regions and patient populations remains controversial. Additionally, point-of-care testing (POCT) cTn assays have the potential to provide troponin readings to physicians within 15 min, but their accuracy in diagnosing NSTEMI in the emergency department (ED) requires further investigation | ||
520 | |a METHODS: A single-center prospective observational cohort study was conducted at Shaanxi Provincial People's Hospital to assess the analytical and diagnostic performance of the laboratory-based Roche Modular E170 hs-cTnT using the 0 h/1 h algorithm with Radiometer AQT90-flex POCT cTnT assay in undifferentiated chest pain patients presenting to the ED. Whole-blood samples were collected and hs-cTnT and POCT cTnI were measured simultaneously at baseline and after 1 h | ||
520 | |a RESULTS: The study results showed that the POCT cTnT assay using the 0 h/1 h algorithm had comparable diagnostic accuracy to the laboratory-based Roche Modular E170 hs-cTnT assay in diagnosing NSTEMI in patients with chest pain | ||
520 | |a CONCLUSION: The laboratory-based Roche Modular E170 hs-cTnT using the 0 h/1 h algorithm is reliable and accurate method for diagnosing NSTEMI in undifferentiated chest pain patients presenting to the ED. POCT cTnT assay has comparable diagnostic accuracy to the hs-cTnT assay and its rapid turnaround time makes it a valuable tool in expediting the diagnostic workup of chest pain patients | ||
650 | 4 | |a Observational Study | |
650 | 4 | |a Journal Article | |
650 | 4 | |a Diagnostic accuracy | |
650 | 4 | |a High-sensitivity cardiac troponin (hs-cTn) 0 h/1 h algorithm | |
650 | 4 | |a Non-ST-segment elevation myocardial infarction (NSTEMI) | |
650 | 4 | |a Point-of-care testing (POCT) cTn assays | |
650 | 7 | |a Troponin T |2 NLM | |
650 | 7 | |a Troponin I |2 NLM | |
650 | 7 | |a Biomarkers |2 NLM | |
700 | 1 | |a Liang, Linyuan |e verfasserin |4 aut | |
700 | 1 | |a Liu, Danping |e verfasserin |4 aut | |
700 | 1 | |a Jia, Jia |e verfasserin |4 aut | |
700 | 1 | |a Dong, Mengya |e verfasserin |4 aut | |
700 | 1 | |a Chen, Haichao |e verfasserin |4 aut | |
700 | 1 | |a Shou, Xiling |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t The American journal of emergency medicine |d 1986 |g 71(2023) vom: 15. Sept., Seite 139-143 |w (DE-627)NLM01297868X |x 1532-8171 |7 nnns |
773 | 1 | 8 | |g volume:71 |g year:2023 |g day:15 |g month:09 |g pages:139-143 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.ajem.2023.06.036 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 71 |j 2023 |b 15 |c 09 |h 139-143 |