Thoracic UltrasONOgraphy Reporting : The TUONO Consensus
The widespread use of the lung ultrasound (LUS) has not been followed by the development of a comprehensive standardized tool for its reporting in the intensive care unit (ICU) which could be useful to promote consistency and reproducibility during clinical examination. This work aims to define the essential features to be included in a standardized reporting tool and provides a structured model form to fully express the diagnostic potential of LUS and facilitate intensivists in the use of a LUS in everyday clinical ICU examination. We conducted a modified Delphi process to build consensus on the items to be integrated in a standardized report form and on its structure. A committee of 19 critical care physicians from 19 participating ICUs in Italy was formed, including intensivists experienced in ultrasound from both teaching hospitals and referral hospitals, and internationally renowned experts on the LUS. The consensus for 31 statements out of 33 was reached at the third Delphi round. A structured model form was developed based on the approved statements. The development of a standardized model as a backbone to report a LUS may facilitate the guidelines' application in clinical practice and increase inter-operator agreement. Further studies are needed to evaluate the effects of standardized reports in critically ill patients.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:13 |
---|---|
Enthalten in: |
Diagnostics (Basel, Switzerland) - 13(2023), 9 vom: 25. Apr. |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Calamai, Italo [VerfasserIn] |
---|
Links: |
---|
Themen: |
Consensus |
---|
Anmerkungen: |
Date Revised 15.05.2023 published: Electronic Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.3390/diagnostics13091535 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM356777022 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM356777022 | ||
003 | DE-627 | ||
005 | 20231226071202.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.3390/diagnostics13091535 |2 doi | |
028 | 5 | 2 | |a pubmed24n1189.xml |
035 | |a (DE-627)NLM356777022 | ||
035 | |a (NLM)37174927 | ||
035 | |a (PII)1535 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Calamai, Italo |e verfasserin |4 aut | |
245 | 1 | 0 | |a Thoracic UltrasONOgraphy Reporting |b The TUONO Consensus |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 15.05.2023 | ||
500 | |a published: Electronic | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a The widespread use of the lung ultrasound (LUS) has not been followed by the development of a comprehensive standardized tool for its reporting in the intensive care unit (ICU) which could be useful to promote consistency and reproducibility during clinical examination. This work aims to define the essential features to be included in a standardized reporting tool and provides a structured model form to fully express the diagnostic potential of LUS and facilitate intensivists in the use of a LUS in everyday clinical ICU examination. We conducted a modified Delphi process to build consensus on the items to be integrated in a standardized report form and on its structure. A committee of 19 critical care physicians from 19 participating ICUs in Italy was formed, including intensivists experienced in ultrasound from both teaching hospitals and referral hospitals, and internationally renowned experts on the LUS. The consensus for 31 statements out of 33 was reached at the third Delphi round. A structured model form was developed based on the approved statements. The development of a standardized model as a backbone to report a LUS may facilitate the guidelines' application in clinical practice and increase inter-operator agreement. Further studies are needed to evaluate the effects of standardized reports in critically ill patients | ||
650 | 4 | |a Guideline | |
650 | 4 | |a consensus | |
650 | 4 | |a lung ultrasound | |
650 | 4 | |a modified Delphi | |
650 | 4 | |a point-of-care | |
650 | 4 | |a report | |
700 | 1 | |a Greco, Massimiliano |e verfasserin |4 aut | |
700 | 1 | |a Savi, Marzia |e verfasserin |4 aut | |
700 | 1 | |a Vitiello, Gaia |e verfasserin |4 aut | |
700 | 1 | |a Garbero, Elena |e verfasserin |4 aut | |
700 | 1 | |a Spina, Rosario |e verfasserin |4 aut | |
700 | 1 | |a Pisani, Luigi |e verfasserin |4 aut | |
700 | 1 | |a Mongodi, Silvia |e verfasserin |4 aut | |
700 | 1 | |a Finazzi, Stefano |e verfasserin |4 aut | |
700 | 1 | |a On Behalf Of The Tuono Study Investigators |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Diagnostics (Basel, Switzerland) |d 2011 |g 13(2023), 9 vom: 25. Apr. |w (DE-627)NLM250111136 |x 2075-4418 |7 nnns |
773 | 1 | 8 | |g volume:13 |g year:2023 |g number:9 |g day:25 |g month:04 |
856 | 4 | 0 | |u http://dx.doi.org/10.3390/diagnostics13091535 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 13 |j 2023 |e 9 |b 25 |c 04 |