Applying novel economic simple green sample preparation procedures on natural and industrial specimens for chromatographic determination of insecticidal residues
© 2023. The Author(s)..
Spraying a tertiary blend of the insecticides (hexythiazox, imidacloprid, and thiamethoxam), on tomato fruits, is a routine in agriculture-attentive countries. A simple green sample preparation technique was developed and applied to the field samples. Specific HP-TLC and RP-HPLC methodologies are established to estimate the residual insecticides and applied to the prepared field specimens. In the planner chromatographic methodology, methanol:chloroform:glacial acetic acid:triethyl amine (8.5:1.5:0.2:0.1, v/v) is recommended as a mobile system. The other one is columnar chromatography; acetonitrile: water (20:80, v/v), pH 2.8, is recommended as a mobile system. The validation parameters were examined following the ICH rules. The means percentages and standard deviations of the accuracy of the HP-TLC method for the determined compounds were 99.66 ± 0.974, 99.41 ± 0.950, and 99.89 ± 0.983, correspondingly. The values were 99.24 ± 0.921, 99.69 ± 0.681, and 99.20 ± 0.692, correspondingly, when they were determined by the RP-HPLC method. The relative standard deviation percentages of the methods' repeatability and intermediate precision ranged from 0.389 to 0.920. Both methods were highly specific having resolution factors of ≥ 1.78 and selectivity factors of ≥ 1.71. They were applied to the field samples perfectly.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:13 |
---|---|
Enthalten in: |
Scientific reports - 13(2023), 1 vom: 03. Mai, Seite 7209 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Hegazy, Amira M [VerfasserIn] |
---|
Links: |
---|
Themen: |
Insecticides |
---|
Anmerkungen: |
Date Completed 05.05.2023 Date Revised 11.05.2023 published: Electronic Citation Status MEDLINE |
---|
doi: |
10.1038/s41598-023-33421-7 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM356412075 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM356412075 | ||
003 | DE-627 | ||
005 | 20231226210324.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1038/s41598-023-33421-7 |2 doi | |
028 | 5 | 2 | |a pubmed24n1187.xml |
035 | |a (DE-627)NLM356412075 | ||
035 | |a (NLM)37137923 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Hegazy, Amira M |e verfasserin |4 aut | |
245 | 1 | 0 | |a Applying novel economic simple green sample preparation procedures on natural and industrial specimens for chromatographic determination of insecticidal residues |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 05.05.2023 | ||
500 | |a Date Revised 11.05.2023 | ||
500 | |a published: Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2023. The Author(s). | ||
520 | |a Spraying a tertiary blend of the insecticides (hexythiazox, imidacloprid, and thiamethoxam), on tomato fruits, is a routine in agriculture-attentive countries. A simple green sample preparation technique was developed and applied to the field samples. Specific HP-TLC and RP-HPLC methodologies are established to estimate the residual insecticides and applied to the prepared field specimens. In the planner chromatographic methodology, methanol:chloroform:glacial acetic acid:triethyl amine (8.5:1.5:0.2:0.1, v/v) is recommended as a mobile system. The other one is columnar chromatography; acetonitrile: water (20:80, v/v), pH 2.8, is recommended as a mobile system. The validation parameters were examined following the ICH rules. The means percentages and standard deviations of the accuracy of the HP-TLC method for the determined compounds were 99.66 ± 0.974, 99.41 ± 0.950, and 99.89 ± 0.983, correspondingly. The values were 99.24 ± 0.921, 99.69 ± 0.681, and 99.20 ± 0.692, correspondingly, when they were determined by the RP-HPLC method. The relative standard deviation percentages of the methods' repeatability and intermediate precision ranged from 0.389 to 0.920. Both methods were highly specific having resolution factors of ≥ 1.78 and selectivity factors of ≥ 1.71. They were applied to the field samples perfectly | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Research Support, Non-U.S. Gov't | |
650 | 7 | |a Insecticides |2 NLM | |
650 | 7 | |a Pesticide Residues |2 NLM | |
700 | 1 | |a Mahmoud, Hamada M |e verfasserin |4 aut | |
700 | 1 | |a Elsayed, Mohamed A |e verfasserin |4 aut | |
700 | 1 | |a Ali, Nouruddin W |e verfasserin |4 aut | |
700 | 1 | |a Abdelfatah, Rehab M |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Scientific reports |d 2011 |g 13(2023), 1 vom: 03. Mai, Seite 7209 |w (DE-627)NLM215703936 |x 2045-2322 |7 nnns |
773 | 1 | 8 | |g volume:13 |g year:2023 |g number:1 |g day:03 |g month:05 |g pages:7209 |
856 | 4 | 0 | |u http://dx.doi.org/10.1038/s41598-023-33421-7 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 13 |j 2023 |e 1 |b 03 |c 05 |h 7209 |