Comparing Static Perimetry Protocols of Central Field Testing among Patients with Glaucoma
Copyright © 2023 American Academy of Optometry..
SIGNIFICANCE: On comparing the Humphrey Field Analyzer (HFA) 24-2C Faster, which tests 10 additional points in the central field, with the 24-2 Swedish Interactive Thresholding Algorithm (SITA) Standard for detecting central field defects, we found that the HFA 24-2C Faster may be used for the initial field evaluation in glaucoma with the advantage of a shorter testing time.
PURPOSE: This study aimed to compare the HFA 24-2C Faster with the 24-2 SITA Standard and 10-2 among patients with glaucoma for the number of defective central points, global indices, and testing time.
METHODS: Sixty eyes of 60 patients with glaucoma and glaucomatous visual field defects on the 24-2 SITA Standard algorithm underwent the 24-2C Faster and 10-2 field tests. The number of central points detected, global indices, and reliability indices were compared between the 24-2C Faster and the 24-2 SITA Standard and 10-2 field tests.
RESULTS: The 24-2C Faster, on average, detected 5.5 defective points more on the total deviation plot and 2 defective points more on the pattern deviation plot than the 24-2 SITA Standard in central 10°. The 10-2 algorithm detected 2.5 times more points on the total deviation plot than the 24-2C Faster. There was excellent consistency by an intraclass correlation coefficient of 0.95 for the mean deviation and 0.93 for the pattern standard deviation between the 24-2C Faster and the 24-2 SITA Standard. There was good consistency by an intraclass correlation coefficient of 0.80 for both mean deviation and pattern standard deviation between the 24-2C Faster and the 10-2. The testing time was significantly lower with the 24-2C Faster compared with the 24-2 SITA Standard and 10-2 test.
CONCLUSIONS: Our study demonstrates that the HFA 24-2C Faster may be used for the initial evaluation of the visual field in glaucoma with the added advantage of a shorter testing time compared with the 24-2 SITA Standard program.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:100 |
---|---|
Enthalten in: |
Optometry and vision science : official publication of the American Academy of Optometry - 100(2023), 6 vom: 01. Juni, Seite 406-411 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Behera, Geeta [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 29.06.2023 Date Revised 23.08.2023 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1097/OPX.0000000000002020 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM356329704 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM356329704 | ||
003 | DE-627 | ||
005 | 20231226070229.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1097/OPX.0000000000002020 |2 doi | |
028 | 5 | 2 | |a pubmed24n1187.xml |
035 | |a (DE-627)NLM356329704 | ||
035 | |a (NLM)37129640 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Behera, Geeta |e verfasserin |4 aut | |
245 | 1 | 0 | |a Comparing Static Perimetry Protocols of Central Field Testing among Patients with Glaucoma |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 29.06.2023 | ||
500 | |a Date Revised 23.08.2023 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2023 American Academy of Optometry. | ||
520 | |a SIGNIFICANCE: On comparing the Humphrey Field Analyzer (HFA) 24-2C Faster, which tests 10 additional points in the central field, with the 24-2 Swedish Interactive Thresholding Algorithm (SITA) Standard for detecting central field defects, we found that the HFA 24-2C Faster may be used for the initial field evaluation in glaucoma with the advantage of a shorter testing time | ||
520 | |a PURPOSE: This study aimed to compare the HFA 24-2C Faster with the 24-2 SITA Standard and 10-2 among patients with glaucoma for the number of defective central points, global indices, and testing time | ||
520 | |a METHODS: Sixty eyes of 60 patients with glaucoma and glaucomatous visual field defects on the 24-2 SITA Standard algorithm underwent the 24-2C Faster and 10-2 field tests. The number of central points detected, global indices, and reliability indices were compared between the 24-2C Faster and the 24-2 SITA Standard and 10-2 field tests | ||
520 | |a RESULTS: The 24-2C Faster, on average, detected 5.5 defective points more on the total deviation plot and 2 defective points more on the pattern deviation plot than the 24-2 SITA Standard in central 10°. The 10-2 algorithm detected 2.5 times more points on the total deviation plot than the 24-2C Faster. There was excellent consistency by an intraclass correlation coefficient of 0.95 for the mean deviation and 0.93 for the pattern standard deviation between the 24-2C Faster and the 24-2 SITA Standard. There was good consistency by an intraclass correlation coefficient of 0.80 for both mean deviation and pattern standard deviation between the 24-2C Faster and the 10-2. The testing time was significantly lower with the 24-2C Faster compared with the 24-2 SITA Standard and 10-2 test | ||
520 | |a CONCLUSIONS: Our study demonstrates that the HFA 24-2C Faster may be used for the initial evaluation of the visual field in glaucoma with the added advantage of a shorter testing time compared with the 24-2 SITA Standard program | ||
650 | 4 | |a Journal Article | |
700 | 1 | |a Nath, Ayush |e verfasserin |4 aut | |
700 | 1 | |a Ramasamy, Amala |e verfasserin |4 aut | |
700 | 1 | |a Kaliaperumal, Subashini |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Optometry and vision science : official publication of the American Academy of Optometry |d 1996 |g 100(2023), 6 vom: 01. Juni, Seite 406-411 |w (DE-627)NLM012814555 |x 1538-9235 |7 nnns |
773 | 1 | 8 | |g volume:100 |g year:2023 |g number:6 |g day:01 |g month:06 |g pages:406-411 |
856 | 4 | 0 | |u http://dx.doi.org/10.1097/OPX.0000000000002020 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 100 |j 2023 |e 6 |b 01 |c 06 |h 406-411 |