Effects of Device Settings and E-Liquid Characteristics on Mouth-Throat Losses of Nicotine Delivered with Electronic Nicotine Delivery Systems (ENDS)
Currently it is not fully understood how the device settings and electronic liquid (e-liquid) composition, including their form of nicotine content, impact mouth and throat losses, and potentially lead to the variations in total nicotine delivery to the human lungs. An in situ size assessment method was developed for real-time measurements at the mouthpiece and outlet of a biorelevant mouth-throat to account for the dynamic nature of the aerosol. The aerosol size, temperature, and delivery through the mouth-throat replica and the exhaled aerosol between the puff intervals were measured at different wattages using various e-liquid compositions. The effects of body temperature and humidity on aerosol size and nicotine delivery were also explored to evaluate the importance of considering realistic in vivo conditions in in vitro measurements. Notably, in vitro tests with body temperature and humidity in mouth-throat model vs room conditions, resulted in larger aerosol size at the end of the throat (Dv50=5.83±0.33 μm vs 3.05±0.15 μm), significantly higher thoracic nicotine delivery (>90% vs 50-85%) potentially due to the lower exhaled amount (<10% vs 15-50%). Besides, higher VG/PG ratios resulted in significantly lower exhaled amount and higher mouth-throat nicotine deposition. One of the main outcomes of the study was finding significantly lower exhaled amount and higher thoracic nicotine delivery with nicotine salt form vs free-base. Considering body temperature and humidity also showed significant enhancement in nicotine delivery, so it is essential to account for biorelevant experimental conditions in benchtop testing.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:171 |
---|---|
Enthalten in: |
Journal of aerosol science - 171(2023) vom: 19. Juni |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Hosseini, Sana [VerfasserIn] |
---|
Links: |
---|
Themen: |
E-liquid compositions |
---|
Anmerkungen: |
Date Revised 26.04.2023 published: Print-Electronic Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.1016/j.jaerosci.2023.106178 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM355957434 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM355957434 | ||
003 | DE-627 | ||
005 | 20231226065438.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.jaerosci.2023.106178 |2 doi | |
028 | 5 | 2 | |a pubmed24n1186.xml |
035 | |a (DE-627)NLM355957434 | ||
035 | |a (NLM)37092025 | ||
035 | |a (PII)106178 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Hosseini, Sana |e verfasserin |4 aut | |
245 | 1 | 0 | |a Effects of Device Settings and E-Liquid Characteristics on Mouth-Throat Losses of Nicotine Delivered with Electronic Nicotine Delivery Systems (ENDS) |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 26.04.2023 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a Currently it is not fully understood how the device settings and electronic liquid (e-liquid) composition, including their form of nicotine content, impact mouth and throat losses, and potentially lead to the variations in total nicotine delivery to the human lungs. An in situ size assessment method was developed for real-time measurements at the mouthpiece and outlet of a biorelevant mouth-throat to account for the dynamic nature of the aerosol. The aerosol size, temperature, and delivery through the mouth-throat replica and the exhaled aerosol between the puff intervals were measured at different wattages using various e-liquid compositions. The effects of body temperature and humidity on aerosol size and nicotine delivery were also explored to evaluate the importance of considering realistic in vivo conditions in in vitro measurements. Notably, in vitro tests with body temperature and humidity in mouth-throat model vs room conditions, resulted in larger aerosol size at the end of the throat (Dv50=5.83±0.33 μm vs 3.05±0.15 μm), significantly higher thoracic nicotine delivery (>90% vs 50-85%) potentially due to the lower exhaled amount (<10% vs 15-50%). Besides, higher VG/PG ratios resulted in significantly lower exhaled amount and higher mouth-throat nicotine deposition. One of the main outcomes of the study was finding significantly lower exhaled amount and higher thoracic nicotine delivery with nicotine salt form vs free-base. Considering body temperature and humidity also showed significant enhancement in nicotine delivery, so it is essential to account for biorelevant experimental conditions in benchtop testing | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Electronic cigarettes | |
650 | 4 | |a e-liquid compositions | |
650 | 4 | |a in vitro biorelevant mouth-throat replica | |
650 | 4 | |a nicotine delivery | |
650 | 4 | |a nicotine form | |
650 | 4 | |a nicotine salt | |
700 | 1 | |a Gholap, Vinit |e verfasserin |4 aut | |
700 | 1 | |a Halquist, Matthew S |e verfasserin |4 aut | |
700 | 1 | |a Golshahi, Laleh |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of aerosol science |d 1976 |g 171(2023) vom: 19. Juni |w (DE-627)NLM012432075 |x 0021-8502 |7 nnns |
773 | 1 | 8 | |g volume:171 |g year:2023 |g day:19 |g month:06 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.jaerosci.2023.106178 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 171 |j 2023 |b 19 |c 06 |