Targeted alveo-pleural fistula endobronchial valve treatment using ventilation scintigraphy
© 2023 The Authors. Respirology Case Reports published by John Wiley & Sons Australia, Ltd on behalf of The Asian Pacific Society of Respirology..
Persistent air-leaks can be difficult to localize in radiology. Bronchoscopic management of air-leaks requires identification of the leak's location to allow suitable targeted treatment. One-way endobronchial valves have become a suitable option for persistent air-leaks. In this report, a combination scintigraphy and one-way endobronchial valve treatment successfully resolved a persistent air-leak.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:11 |
---|---|
Enthalten in: |
Respirology case reports - 11(2023), 5 vom: 12. Mai, Seite e01146 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Sidhu, Calvin [VerfasserIn] |
---|
Links: |
---|
Themen: |
Alveo‐pleural fistula |
---|
Anmerkungen: |
Date Revised 22.04.2023 published: Electronic-eCollection Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.1002/rcr2.1146 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM355859548 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM355859548 | ||
003 | DE-627 | ||
005 | 20231226065235.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1002/rcr2.1146 |2 doi | |
028 | 5 | 2 | |a pubmed24n1186.xml |
035 | |a (DE-627)NLM355859548 | ||
035 | |a (NLM)37082168 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Sidhu, Calvin |e verfasserin |4 aut | |
245 | 1 | 0 | |a Targeted alveo-pleural fistula endobronchial valve treatment using ventilation scintigraphy |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 22.04.2023 | ||
500 | |a published: Electronic-eCollection | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a © 2023 The Authors. Respirology Case Reports published by John Wiley & Sons Australia, Ltd on behalf of The Asian Pacific Society of Respirology. | ||
520 | |a Persistent air-leaks can be difficult to localize in radiology. Bronchoscopic management of air-leaks requires identification of the leak's location to allow suitable targeted treatment. One-way endobronchial valves have become a suitable option for persistent air-leaks. In this report, a combination scintigraphy and one-way endobronchial valve treatment successfully resolved a persistent air-leak | ||
650 | 4 | |a Case Reports | |
650 | 4 | |a alveo‐pleural fistula | |
650 | 4 | |a bronchoscopy | |
650 | 4 | |a endobronchial | |
650 | 4 | |a interventional | |
650 | 4 | |a valve | |
700 | 1 | |a Ratnagobal, Shoba |e verfasserin |4 aut | |
700 | 1 | |a Thomas, Rajesh |e verfasserin |4 aut | |
700 | 1 | |a Lee, Gary Y C |e verfasserin |4 aut | |
700 | 1 | |a Drudy, Enya |e verfasserin |4 aut | |
700 | 1 | |a Francis, Roslyn J |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Respirology case reports |d 2013 |g 11(2023), 5 vom: 12. Mai, Seite e01146 |w (DE-627)NLM244269440 |x 2051-3380 |7 nnns |
773 | 1 | 8 | |g volume:11 |g year:2023 |g number:5 |g day:12 |g month:05 |g pages:e01146 |
856 | 4 | 0 | |u http://dx.doi.org/10.1002/rcr2.1146 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 11 |j 2023 |e 5 |b 12 |c 05 |h e01146 |