The optimal diagnostic cut-off of WBC and PMN counts for joint aspiration in periprosthetic joint infection is 2479/µL and 67%, respectively : ICM criteria thresholds are too high
© 2023. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature..
BACKGROUND: Various organizations have published definitions for periprosthetic joint infection (PJI) with significant differences in the cut-offs of white blood cell (WBC) count and polymorphonuclear (PMN) leukocyte cells. Herein, we aim to analyze optimal cut-offs in patients which are planned to undergo a prosthesis revision and compare them with the actual published thresholds of the International Consensus Meeting (ICM) and European Bone and Joint Infection Society (EBJIS).
METHODS: A test kit was compiled in a monocentric prospective study, according to the ICM criteria (2018) and 2021 EBJIS criteria. The kit was implemented using: blood samples (including leukocyte count and C-reactive protein); samples for examining the synovial fluid (WBC count, PMN cell differentiation, microbiological culture for incubation over 14 days, alpha-defensin ELISA laboratory test, and leukocyte-esterase test). The cut-offs for WBC and PMN counts were investigated using ROC analyses and Youden index. The ICM 2018 criteria were applied, using alpha-defensin in all cases. Patients which have to undergo a prosthesis revision were included, a pre-operative joint aspiration had been performed, and the patients had been followed up prospectively.
RESULTS: 405 patients were examined with the compiled test kit; 100% had a complete dataset with respect to alpha-defensin; 383 patients, according to WBC count; and 256, according to PMN cell differentiation The cut-off of 2478.89 cells/µl in the WBC count (sensitivity: 87.70%; specificity: 88.10%) and the cut-off of 66.99% in PMN differentiation showed the best accuracy (sensitivity: 86.00%; specificity: 88.80%). Other published cut-offs for WBC were tested in this cohort and showed the following accuracy: 3000/µl (EBJIS/ICM; sensitivity: 82.10%; specificity: 91.00%), 2000/µl (sensitivity: 89.60%; specificity: 83.40%), and 1500/µl (sensitivity: 91.50%; specificity: 75.00%). The published cut-offs for PMN had the following accuracy in this cohort: 80% (ICM; sensitivity: 66.3%; specificity: 96.50%), 70% (sensitivity: 82.6%; specificity: 90%), and 65% (EBJIS, sensitivity: 86%; specificity: 88.8%).
CONCLUSIONS: This study aims to improve current cut-offs for PMN- and WB-Count, even though PJI diagnosis is based on the combination of all defined tests. The optimal diagnostic cut-off of WBC and PMN counts was found to be 2479/µL and 67%, respectively, whereas ICM cut-offs in this cohort seem too high, as they provide high specificity but very low sensitivity. On the other hand, a cut-off for WBC count of 1500/µl alone would be very low, leading to low specificity and very high suspicion of PJI. The current consensus guidelines could be actualized considering these results to significantly improve the diagnostic quality.
LEVEL OF EVIDENCE: II.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:143 |
---|---|
Enthalten in: |
Archives of orthopaedic and trauma surgery - 143(2023), 8 vom: 20. Aug., Seite 5229-5238 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Gramlich, Y [VerfasserIn] |
---|
Links: |
---|
Themen: |
Alpha-Defensins |
---|
Anmerkungen: |
Date Completed 31.07.2023 Date Revised 31.07.2023 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1007/s00402-023-04822-0 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM354468588 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM354468588 | ||
003 | DE-627 | ||
005 | 20231226062304.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1007/s00402-023-04822-0 |2 doi | |
028 | 5 | 2 | |a pubmed24n1181.xml |
035 | |a (DE-627)NLM354468588 | ||
035 | |a (NLM)36941499 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Gramlich, Y |e verfasserin |4 aut | |
245 | 1 | 4 | |a The optimal diagnostic cut-off of WBC and PMN counts for joint aspiration in periprosthetic joint infection is 2479/µL and 67%, respectively |b ICM criteria thresholds are too high |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 31.07.2023 | ||
500 | |a Date Revised 31.07.2023 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2023. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature. | ||
520 | |a BACKGROUND: Various organizations have published definitions for periprosthetic joint infection (PJI) with significant differences in the cut-offs of white blood cell (WBC) count and polymorphonuclear (PMN) leukocyte cells. Herein, we aim to analyze optimal cut-offs in patients which are planned to undergo a prosthesis revision and compare them with the actual published thresholds of the International Consensus Meeting (ICM) and European Bone and Joint Infection Society (EBJIS) | ||
520 | |a METHODS: A test kit was compiled in a monocentric prospective study, according to the ICM criteria (2018) and 2021 EBJIS criteria. The kit was implemented using: blood samples (including leukocyte count and C-reactive protein); samples for examining the synovial fluid (WBC count, PMN cell differentiation, microbiological culture for incubation over 14 days, alpha-defensin ELISA laboratory test, and leukocyte-esterase test). The cut-offs for WBC and PMN counts were investigated using ROC analyses and Youden index. The ICM 2018 criteria were applied, using alpha-defensin in all cases. Patients which have to undergo a prosthesis revision were included, a pre-operative joint aspiration had been performed, and the patients had been followed up prospectively | ||
520 | |a RESULTS: 405 patients were examined with the compiled test kit; 100% had a complete dataset with respect to alpha-defensin; 383 patients, according to WBC count; and 256, according to PMN cell differentiation The cut-off of 2478.89 cells/µl in the WBC count (sensitivity: 87.70%; specificity: 88.10%) and the cut-off of 66.99% in PMN differentiation showed the best accuracy (sensitivity: 86.00%; specificity: 88.80%). Other published cut-offs for WBC were tested in this cohort and showed the following accuracy: 3000/µl (EBJIS/ICM; sensitivity: 82.10%; specificity: 91.00%), 2000/µl (sensitivity: 89.60%; specificity: 83.40%), and 1500/µl (sensitivity: 91.50%; specificity: 75.00%). The published cut-offs for PMN had the following accuracy in this cohort: 80% (ICM; sensitivity: 66.3%; specificity: 96.50%), 70% (sensitivity: 82.6%; specificity: 90%), and 65% (EBJIS, sensitivity: 86%; specificity: 88.8%) | ||
520 | |a CONCLUSIONS: This study aims to improve current cut-offs for PMN- and WB-Count, even though PJI diagnosis is based on the combination of all defined tests. The optimal diagnostic cut-off of WBC and PMN counts was found to be 2479/µL and 67%, respectively, whereas ICM cut-offs in this cohort seem too high, as they provide high specificity but very low sensitivity. On the other hand, a cut-off for WBC count of 1500/µl alone would be very low, leading to low specificity and very high suspicion of PJI. The current consensus guidelines could be actualized considering these results to significantly improve the diagnostic quality | ||
520 | |a LEVEL OF EVIDENCE: II | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Alpha-defensin | |
650 | 4 | |a EBJIS criteria | |
650 | 4 | |a ICM consensus criteria | |
650 | 4 | |a PJI test kit | |
650 | 4 | |a Periprosthetic joint infection | |
650 | 4 | |a Polymorphonuclear cell | |
650 | 4 | |a White blood cell count | |
650 | 7 | |a alpha-Defensins |2 NLM | |
650 | 7 | |a Biomarkers |2 NLM | |
700 | 1 | |a Schnetz, M |e verfasserin |4 aut | |
700 | 1 | |a Ruckes, C |e verfasserin |4 aut | |
700 | 1 | |a Kemmerer, M |e verfasserin |4 aut | |
700 | 1 | |a Kremer, M |e verfasserin |4 aut | |
700 | 1 | |a Hoffmann, R |e verfasserin |4 aut | |
700 | 1 | |a Klug, A |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Archives of orthopaedic and trauma surgery |d 1996 |g 143(2023), 8 vom: 20. Aug., Seite 5229-5238 |w (DE-627)NLM01295120X |x 1434-3916 |7 nnns |
773 | 1 | 8 | |g volume:143 |g year:2023 |g number:8 |g day:20 |g month:08 |g pages:5229-5238 |
856 | 4 | 0 | |u http://dx.doi.org/10.1007/s00402-023-04822-0 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 143 |j 2023 |e 8 |b 20 |c 08 |h 5229-5238 |