Incorporating heterogeneity and anisotropy for surgical applications in breast deformation modeling
Copyright © 2023 Elsevier Ltd. All rights reserved..
BACKGROUND: Simulating soft-tissue breast deformations is of interest for many applications including image fusion, longitudinal registration, and image-guided surgery. For the surgical use case, positional changes cause breast deformations that compromise the use of preoperative imaging to inform tumor excision. Even when acquiring imaging in the supine position, which better reflects surgical presentation, deformations still occur due to arm motion and orientation changes. A biomechanical modeling approach to simulate supine breast deformations for surgical applications must be both accurate and compatible with the clinical workflow.
METHODS: A supine MR breast imaging dataset from n = 11 healthy volunteers was used to simulate surgical deformations by acquiring images in arm-down and arm-up positions. Three linear-elastic modeling approaches with varying levels of complexity were used to predict deformations caused by this arm motion: a homogeneous isotropic model, a heterogeneous isotropic model, and a heterogeneous anisotropic model using a transverse-isotropic constitutive model.
FINDINGS: The average target registration errors for subsurface anatomical features were 5.4 ± 1.5 mm for the homogeneous isotropic model, 5.3 ± 1.5 mm for the heterogeneous isotropic model, and 4.7 ± 1.4 mm for the heterogeneous anisotropic model. A statistically significant improvement in target registration error was observed between the heterogeneous anisotropic model and both the homogeneous and the heterogeneous isotropic models (P < 0.01).
INTERPRETATION: While a model that fully incorporates all constitutive complexities of anatomical structure likely achieves the best accuracy, a computationally tractable heterogeneous anisotropic model provided significant improvement and may be applicable for image-guided breast surgeries.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:104 |
---|---|
Enthalten in: |
Clinical biomechanics (Bristol, Avon) - 104(2023) vom: 14. Apr., Seite 105927 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Ringel, Morgan J [VerfasserIn] |
---|
Links: |
---|
Themen: |
Breast cancer |
---|
Anmerkungen: |
Date Completed 25.04.2023 Date Revised 02.04.2024 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.clinbiomech.2023.105927 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM353957925 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM353957925 | ||
003 | DE-627 | ||
005 | 20240402235520.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.clinbiomech.2023.105927 |2 doi | |
028 | 5 | 2 | |a pubmed24n1361.xml |
035 | |a (DE-627)NLM353957925 | ||
035 | |a (NLM)36890069 | ||
035 | |a (PII)S0268-0033(23)00058-X | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Ringel, Morgan J |e verfasserin |4 aut | |
245 | 1 | 0 | |a Incorporating heterogeneity and anisotropy for surgical applications in breast deformation modeling |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 25.04.2023 | ||
500 | |a Date Revised 02.04.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2023 Elsevier Ltd. All rights reserved. | ||
520 | |a BACKGROUND: Simulating soft-tissue breast deformations is of interest for many applications including image fusion, longitudinal registration, and image-guided surgery. For the surgical use case, positional changes cause breast deformations that compromise the use of preoperative imaging to inform tumor excision. Even when acquiring imaging in the supine position, which better reflects surgical presentation, deformations still occur due to arm motion and orientation changes. A biomechanical modeling approach to simulate supine breast deformations for surgical applications must be both accurate and compatible with the clinical workflow | ||
520 | |a METHODS: A supine MR breast imaging dataset from n = 11 healthy volunteers was used to simulate surgical deformations by acquiring images in arm-down and arm-up positions. Three linear-elastic modeling approaches with varying levels of complexity were used to predict deformations caused by this arm motion: a homogeneous isotropic model, a heterogeneous isotropic model, and a heterogeneous anisotropic model using a transverse-isotropic constitutive model | ||
520 | |a FINDINGS: The average target registration errors for subsurface anatomical features were 5.4 ± 1.5 mm for the homogeneous isotropic model, 5.3 ± 1.5 mm for the heterogeneous isotropic model, and 4.7 ± 1.4 mm for the heterogeneous anisotropic model. A statistically significant improvement in target registration error was observed between the heterogeneous anisotropic model and both the homogeneous and the heterogeneous isotropic models (P < 0.01) | ||
520 | |a INTERPRETATION: While a model that fully incorporates all constitutive complexities of anatomical structure likely achieves the best accuracy, a computationally tractable heterogeneous anisotropic model provided significant improvement and may be applicable for image-guided breast surgeries | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Research Support, N.I.H., Extramural | |
650 | 4 | |a Research Support, U.S. Gov't, Non-P.H.S. | |
650 | 4 | |a Breast cancer | |
650 | 4 | |a FEM | |
650 | 4 | |a Lumpectomy | |
650 | 4 | |a Registration | |
650 | 4 | |a Surgical guidance | |
700 | 1 | |a Richey, Winona L |e verfasserin |4 aut | |
700 | 1 | |a Heiselman, Jon S |e verfasserin |4 aut | |
700 | 1 | |a Meszoely, Ingrid M |e verfasserin |4 aut | |
700 | 1 | |a Miga, Michael I |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Clinical biomechanics (Bristol, Avon) |d 1986 |g 104(2023) vom: 14. Apr., Seite 105927 |w (DE-627)NLM085859559 |x 1879-1271 |7 nnns |
773 | 1 | 8 | |g volume:104 |g year:2023 |g day:14 |g month:04 |g pages:105927 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.clinbiomech.2023.105927 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 104 |j 2023 |b 14 |c 04 |h 105927 |