The diagnostic performance of artificial intelligence algorithms for identifying M2 segment middle cerebral artery occlusions : A systematic review and meta-analysis
Copyright © 2023 Elsevier Masson SAS. All rights reserved..
BACKGROUND: Artificial intelligence (AI)-based algorithms have been developed to facilitate rapid and accurate computed tomography angiography (CTA) assessment in proximal large vessel occlusion (LVO) acute ischemic stroke, including internal carotid artery and M1 occlusions. In clinical practice, however, the detection of medium vessel occlusion (MeVO) represents an ongoing diagnostic challenge in which the added value of AI remains unclear.
PURPOSE: To assess the diagnostic performance of AI platforms for detecting M2 occlusions.
METHODS: Studies that report the diagnostic performance of AI-based detection of M2 occlusions were screened, and sensitivity and specificity data were extracted using the semi-automated AutoLit software (Nested Knowledge, MN) platform. STATA (version 16 IC; Stata Corporation, College Station, Texas, USA) was used to conduct all analyses.
RESULTS: Eight studies with a low risk of bias and significant heterogeneity were included in the quantitative and qualitative synthesis. The pooled estimates of sensitivity and specificity of AI platforms for M2 occlusion detection were 64% (95% CI, 53 to 74%) and 97% (95% CI, 84 to 100%), respectively. The area under the curve (AUC) in the SROC curve was 0.79 (95% CI, 0.74 to 0.83).
CONCLUSION: The current performance of the AI-based algorithm makes it more suitable as an adjunctive confirmatory tool rather than as an independent one for M2 occlusions. With the rapid development of such algorithms, it is anticipated that newer generations will likely perform much better.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:50 |
---|---|
Enthalten in: |
Journal of neuroradiology = Journal de neuroradiologie - 50(2023), 4 vom: 11. Juni, Seite 449-454 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Ghozy, Sherief [VerfasserIn] |
---|
Links: |
---|
Themen: |
Artificial intelligence |
---|
Anmerkungen: |
Date Completed 29.05.2023 Date Revised 19.03.2024 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.neurad.2023.02.001 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM352835427 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM352835427 | ||
003 | DE-627 | ||
005 | 20240319232126.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.neurad.2023.02.001 |2 doi | |
028 | 5 | 2 | |a pubmed24n1336.xml |
035 | |a (DE-627)NLM352835427 | ||
035 | |a (NLM)36773845 | ||
035 | |a (PII)S0150-9861(23)00166-9 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Ghozy, Sherief |e verfasserin |4 aut | |
245 | 1 | 4 | |a The diagnostic performance of artificial intelligence algorithms for identifying M2 segment middle cerebral artery occlusions |b A systematic review and meta-analysis |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 29.05.2023 | ||
500 | |a Date Revised 19.03.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2023 Elsevier Masson SAS. All rights reserved. | ||
520 | |a BACKGROUND: Artificial intelligence (AI)-based algorithms have been developed to facilitate rapid and accurate computed tomography angiography (CTA) assessment in proximal large vessel occlusion (LVO) acute ischemic stroke, including internal carotid artery and M1 occlusions. In clinical practice, however, the detection of medium vessel occlusion (MeVO) represents an ongoing diagnostic challenge in which the added value of AI remains unclear | ||
520 | |a PURPOSE: To assess the diagnostic performance of AI platforms for detecting M2 occlusions | ||
520 | |a METHODS: Studies that report the diagnostic performance of AI-based detection of M2 occlusions were screened, and sensitivity and specificity data were extracted using the semi-automated AutoLit software (Nested Knowledge, MN) platform. STATA (version 16 IC; Stata Corporation, College Station, Texas, USA) was used to conduct all analyses | ||
520 | |a RESULTS: Eight studies with a low risk of bias and significant heterogeneity were included in the quantitative and qualitative synthesis. The pooled estimates of sensitivity and specificity of AI platforms for M2 occlusion detection were 64% (95% CI, 53 to 74%) and 97% (95% CI, 84 to 100%), respectively. The area under the curve (AUC) in the SROC curve was 0.79 (95% CI, 0.74 to 0.83) | ||
520 | |a CONCLUSION: The current performance of the AI-based algorithm makes it more suitable as an adjunctive confirmatory tool rather than as an independent one for M2 occlusions. With the rapid development of such algorithms, it is anticipated that newer generations will likely perform much better | ||
650 | 4 | |a Meta-Analysis | |
650 | 4 | |a Systematic Review | |
650 | 4 | |a Journal Article | |
650 | 4 | |a Artificial intelligence | |
650 | 4 | |a Deep learning | |
650 | 4 | |a Diagnostic performance | |
650 | 4 | |a Middle cerebral artery | |
700 | 1 | |a Azzam, Ahmed Y |e verfasserin |4 aut | |
700 | 1 | |a Kallmes, Kevin M |e verfasserin |4 aut | |
700 | 1 | |a Matsoukas, Stavros |e verfasserin |4 aut | |
700 | 1 | |a Fifi, Johanna T |e verfasserin |4 aut | |
700 | 1 | |a Luijten, Sven P R |e verfasserin |4 aut | |
700 | 1 | |a van der Lugt, Aad |e verfasserin |4 aut | |
700 | 1 | |a Adusumilli, Gautam |e verfasserin |4 aut | |
700 | 1 | |a Heit, Jeremy J |e verfasserin |4 aut | |
700 | 1 | |a Kadirvel, Ramanathan |e verfasserin |4 aut | |
700 | 1 | |a Kallmes, David F |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of neuroradiology = Journal de neuroradiologie |d 1993 |g 50(2023), 4 vom: 11. Juni, Seite 449-454 |w (DE-627)NLM000403512 |x 0150-9861 |7 nnns |
773 | 1 | 8 | |g volume:50 |g year:2023 |g number:4 |g day:11 |g month:06 |g pages:449-454 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.neurad.2023.02.001 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 50 |j 2023 |e 4 |b 11 |c 06 |h 449-454 |