Disparities in Continuous Glucose Monitoring Use Among Women of Reproductive Age with Type 1 Diabetes in the T1D Exchange
We identified characteristics associated with continuous glucose monitoring (CGM) use in women of reproductive age with type 1 diabetes (T1D) in the T1D Exchange clinic registry from 2015 to 2018. Among 6643 assessed women, the frequency of CGM increased from 2015 to 2018 (20.6% vs. 30.0%; adjusted odds ratios [aOR]: 1.72; confidence interval [95% CI]: 1.51-1.95) and was more likely with recent pregnancy (45.3% vs. 25.8%; aOR: 1.63; 95% CI: 1.23-2.16). Non-Hispanic Black and Hispanic race and ethnicity, younger age, lower educational attainment, lower income, and Medicaid insurance were associated with lower odds of CGM. The use of CGM was associated with lower odds of diabetic ketoacidosis and lower hemoglobin A1c without any difference in the odds of symptomatic severe hypoglycemia. In conclusion, although CGM use was associated with better glycemic control, the majority of reproductive-age women still did not use it. Those who did not use CGM were more likely to be those at greatest risk of adverse pregnancy outcomes.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:25 |
---|---|
Enthalten in: |
Diabetes technology & therapeutics - 25(2023), 3 vom: 01. März, Seite 201-205 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Venkatesh, Kartik K [VerfasserIn] |
---|
Links: |
---|
Anmerkungen: |
Date Completed 03.03.2023 Date Revised 02.03.2024 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1089/dia.2022.0412 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM352635746 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM352635746 | ||
003 | DE-627 | ||
005 | 20240302232120.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1089/dia.2022.0412 |2 doi | |
028 | 5 | 2 | |a pubmed24n1314.xml |
035 | |a (DE-627)NLM352635746 | ||
035 | |a (NLM)36753706 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Venkatesh, Kartik K |e verfasserin |4 aut | |
245 | 1 | 0 | |a Disparities in Continuous Glucose Monitoring Use Among Women of Reproductive Age with Type 1 Diabetes in the T1D Exchange |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 03.03.2023 | ||
500 | |a Date Revised 02.03.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a We identified characteristics associated with continuous glucose monitoring (CGM) use in women of reproductive age with type 1 diabetes (T1D) in the T1D Exchange clinic registry from 2015 to 2018. Among 6643 assessed women, the frequency of CGM increased from 2015 to 2018 (20.6% vs. 30.0%; adjusted odds ratios [aOR]: 1.72; confidence interval [95% CI]: 1.51-1.95) and was more likely with recent pregnancy (45.3% vs. 25.8%; aOR: 1.63; 95% CI: 1.23-2.16). Non-Hispanic Black and Hispanic race and ethnicity, younger age, lower educational attainment, lower income, and Medicaid insurance were associated with lower odds of CGM. The use of CGM was associated with lower odds of diabetic ketoacidosis and lower hemoglobin A1c without any difference in the odds of symptomatic severe hypoglycemia. In conclusion, although CGM use was associated with better glycemic control, the majority of reproductive-age women still did not use it. Those who did not use CGM were more likely to be those at greatest risk of adverse pregnancy outcomes | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Research Support, Non-U.S. Gov't | |
650 | 4 | |a Research Support, U.S. Gov't, P.H.S. | |
650 | 4 | |a Continuous glucose monitoring | |
650 | 4 | |a Disparities | |
650 | 4 | |a Periconception | |
650 | 4 | |a Pregnancy | |
650 | 4 | |a Type 1 diabetes | |
650 | 4 | |a Women | |
650 | 7 | |a Blood Glucose |2 NLM | |
650 | 7 | |a Glycated Hemoglobin |2 NLM | |
700 | 1 | |a Powe, Camille E |e verfasserin |4 aut | |
700 | 1 | |a Buschur, Elizabeth |e verfasserin |4 aut | |
700 | 1 | |a Wu, Jiqiang |e verfasserin |4 aut | |
700 | 1 | |a Landon, Mark B |e verfasserin |4 aut | |
700 | 1 | |a Gabbe, Steven |e verfasserin |4 aut | |
700 | 1 | |a Gandhi, Kajal |e verfasserin |4 aut | |
700 | 1 | |a Grobman, William A |e verfasserin |4 aut | |
700 | 1 | |a Fareed, Naleef |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Diabetes technology & therapeutics |d 1999 |g 25(2023), 3 vom: 01. März, Seite 201-205 |w (DE-627)NLM113690495 |x 1557-8593 |7 nnns |
773 | 1 | 8 | |g volume:25 |g year:2023 |g number:3 |g day:01 |g month:03 |g pages:201-205 |
856 | 4 | 0 | |u http://dx.doi.org/10.1089/dia.2022.0412 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 25 |j 2023 |e 3 |b 01 |c 03 |h 201-205 |