A Comparative Study on Visual Detection of Mycobacterium tuberculosis by Closed Tube Loop-Mediated Isothermal Amplification : Shedding Light on the Use of Eriochrome Black T
Loop-mediated isothermal amplification is a promising candidate for the rapid detection of Mycobacterium tuberculosis. However, the high potential for carry-over contamination is the main obstacle to its routine use. Here, a closed tube LAMP was intended for the visual detection of Mtb to compare turbidimetric and two more favorable colorimetric methods using calcein and hydroxy naphthol blue (HNB). Additionally, a less studied dye (i.e., eriochrome black T (EBT)) was optimized in detail in the reaction for the first time. Mtb purified DNA and 30 clinical specimens were used to respectively determine the analytical and diagnostic sensitivities of each method. The turbidimetric method resulted in the best analytical sensitivity (100 fg DNA/reaction), diagnostic sensitivity and specificity (100%), and time-to-positivity of the test (15 min). However, this method is highly prone to subjective error in reading the results. Moreover, HNB-, calcein-, and EBT-LAMP could respectively detect 100 fg, 1 pg, and 1 pg DNA/reaction (the analytical sensitivities) in 30, 15, and 30 min, while the diagnostic sensitivity and specificity were respectively 93.3% and 100% for them all. Interestingly, EBT-LAMP showed the lowest potential for subjective error in reading the results. This report helps judiciously choose the most appropriate visual method, taking a step forward toward the field applicability of LAMP for the detection of Mtb, particularly in resource-limited settings.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:13 |
---|---|
Enthalten in: |
Diagnostics (Basel, Switzerland) - 13(2023), 1 vom: 02. Jan. |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Neshani, Alireza [VerfasserIn] |
---|
Links: |
---|
Themen: |
Calcein |
---|
Anmerkungen: |
Date Revised 11.01.2023 published: Electronic Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.3390/diagnostics13010155 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM351225390 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM351225390 | ||
003 | DE-627 | ||
005 | 20231226050841.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.3390/diagnostics13010155 |2 doi | |
028 | 5 | 2 | |a pubmed24n1170.xml |
035 | |a (DE-627)NLM351225390 | ||
035 | |a (NLM)36611447 | ||
035 | |a (PII)155 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Neshani, Alireza |e verfasserin |4 aut | |
245 | 1 | 2 | |a A Comparative Study on Visual Detection of Mycobacterium tuberculosis by Closed Tube Loop-Mediated Isothermal Amplification |b Shedding Light on the Use of Eriochrome Black T |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 11.01.2023 | ||
500 | |a published: Electronic | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a Loop-mediated isothermal amplification is a promising candidate for the rapid detection of Mycobacterium tuberculosis. However, the high potential for carry-over contamination is the main obstacle to its routine use. Here, a closed tube LAMP was intended for the visual detection of Mtb to compare turbidimetric and two more favorable colorimetric methods using calcein and hydroxy naphthol blue (HNB). Additionally, a less studied dye (i.e., eriochrome black T (EBT)) was optimized in detail in the reaction for the first time. Mtb purified DNA and 30 clinical specimens were used to respectively determine the analytical and diagnostic sensitivities of each method. The turbidimetric method resulted in the best analytical sensitivity (100 fg DNA/reaction), diagnostic sensitivity and specificity (100%), and time-to-positivity of the test (15 min). However, this method is highly prone to subjective error in reading the results. Moreover, HNB-, calcein-, and EBT-LAMP could respectively detect 100 fg, 1 pg, and 1 pg DNA/reaction (the analytical sensitivities) in 30, 15, and 30 min, while the diagnostic sensitivity and specificity were respectively 93.3% and 100% for them all. Interestingly, EBT-LAMP showed the lowest potential for subjective error in reading the results. This report helps judiciously choose the most appropriate visual method, taking a step forward toward the field applicability of LAMP for the detection of Mtb, particularly in resource-limited settings | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a EBT | |
650 | 4 | |a HNB | |
650 | 4 | |a LAMP | |
650 | 4 | |a Mycobacterium tuberculosis | |
650 | 4 | |a calcein | |
650 | 4 | |a visual detection | |
700 | 1 | |a Zare, Hosna |e verfasserin |4 aut | |
700 | 1 | |a Sadeghian, Hamid |e verfasserin |4 aut | |
700 | 1 | |a Safdari, Hadi |e verfasserin |4 aut | |
700 | 1 | |a Riahi-Zanjani, Bamdad |e verfasserin |4 aut | |
700 | 1 | |a Aryan, Ehsan |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Diagnostics (Basel, Switzerland) |d 2011 |g 13(2023), 1 vom: 02. Jan. |w (DE-627)NLM250111136 |x 2075-4418 |7 nnns |
773 | 1 | 8 | |g volume:13 |g year:2023 |g number:1 |g day:02 |g month:01 |
856 | 4 | 0 | |u http://dx.doi.org/10.3390/diagnostics13010155 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 13 |j 2023 |e 1 |b 02 |c 01 |