Accuracy of the KontrolFlex AccuFile when used with the Root ZX electronic apex locator in vitro
© 2022 The Authors. Australian Endodontic Journal published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Endodontology Inc..
The aims of this study were to determine the efficacy of the KontrolFlex™ Accufile™ compared to the READY•STEEL™ Flexofile® using an electronic apex locator and to evaluate the instrument's design via scanning electron microscopy. Actual canal lengths of 30 extracted teeth were determined under magnification. An alginate model was used to determine experimental canal lengths with the Root ZX II apex locator (EAL) and size #10 Accufiles and Flexofiles. Differences between actual lengths and experimental lengths were compared with Student's t test. The average experimental lengths were short of the actual length by -0.10 mm (±0.34) and -0.12 mm (±0.16) for the Accufile and Flexofile, respectively with no statistical difference (p > 0.05). SEM images revealed similar non-cutting Batt tips and a square cross-section for the Accufile and triangular for the Flexofile. Both files provided similarly high levels of reliability when used with the Root ZX II EAL.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:49 Suppl 1 |
---|---|
Enthalten in: |
Australian endodontic journal : the journal of the Australian Society of Endodontology Inc - 49 Suppl 1(2023) vom: 20. Sept., Seite 253-258 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Tittle, Mia [VerfasserIn] |
---|
Links: |
---|
Themen: |
Electronic apex locator |
---|
Anmerkungen: |
Date Completed 18.09.2023 Date Revised 18.09.2023 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1111/aej.12727 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM349927758 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM349927758 | ||
003 | DE-627 | ||
005 | 20231226043807.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1111/aej.12727 |2 doi | |
028 | 5 | 2 | |a pubmed24n1166.xml |
035 | |a (DE-627)NLM349927758 | ||
035 | |a (NLM)36480435 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Tittle, Mia |e verfasserin |4 aut | |
245 | 1 | 0 | |a Accuracy of the KontrolFlex AccuFile when used with the Root ZX electronic apex locator in vitro |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 18.09.2023 | ||
500 | |a Date Revised 18.09.2023 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2022 The Authors. Australian Endodontic Journal published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Endodontology Inc. | ||
520 | |a The aims of this study were to determine the efficacy of the KontrolFlex™ Accufile™ compared to the READY•STEEL™ Flexofile® using an electronic apex locator and to evaluate the instrument's design via scanning electron microscopy. Actual canal lengths of 30 extracted teeth were determined under magnification. An alginate model was used to determine experimental canal lengths with the Root ZX II apex locator (EAL) and size #10 Accufiles and Flexofiles. Differences between actual lengths and experimental lengths were compared with Student's t test. The average experimental lengths were short of the actual length by -0.10 mm (±0.34) and -0.12 mm (±0.16) for the Accufile and Flexofile, respectively with no statistical difference (p > 0.05). SEM images revealed similar non-cutting Batt tips and a square cross-section for the Accufile and triangular for the Flexofile. Both files provided similarly high levels of reliability when used with the Root ZX II EAL | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a KontrolFlex Accufile | |
650 | 4 | |a Root ZX II | |
650 | 4 | |a electronic apex locator | |
650 | 4 | |a root canal length | |
650 | 4 | |a working length | |
700 | 1 | |a Dunlap, Craig A |e verfasserin |4 aut | |
700 | 1 | |a Scott, Raymond |e verfasserin |4 aut | |
700 | 1 | |a Arias, Ana |e verfasserin |4 aut | |
700 | 1 | |a Davis, Scott |e verfasserin |4 aut | |
700 | 1 | |a Peters, Ove |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Australian endodontic journal : the journal of the Australian Society of Endodontology Inc |d 1998 |g 49 Suppl 1(2023) vom: 20. Sept., Seite 253-258 |w (DE-627)NLM112652816 |x 1747-4477 |7 nnns |
773 | 1 | 8 | |g volume:49 Suppl 1 |g year:2023 |g day:20 |g month:09 |g pages:253-258 |
856 | 4 | 0 | |u http://dx.doi.org/10.1111/aej.12727 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 49 Suppl 1 |j 2023 |b 20 |c 09 |h 253-258 |