Detection of Salmonella Typhimurium with Gold Nanoparticles Using Quartz Crystal Microbalance Biosensor
Demonstration of the Salmonella Typhimurium detection system was shown utilizing a quartz crystal microbalance (QCM) biosensor and signal enhancement by gold nanoparticles. In this study, a benchtop system of a QCM biosensor was utilized for the detection of Salmonella Typhimurium. It was designed with a peristaltic pump system to achieve immobilization of antibodies, detection of Salmonella, and the addition of gold nanoparticles to the sensor. As a series of biochemical solutions were introduced to the surface, the proposed system was able to track the changes in the resonant frequency which were proportional to the variations of mass on the sensor. For antibody immobilization, polyclonal antibodies were immobilized via self-assembled monolayers to detect Salmonella O-antigen. Subsequently, Salmonella Typhimurium was detected by antibodies and the average frequency before and after detecting Salmonella was compared. The highest frequency shifts were −26.91 Hz for 109 CFU/mL while the smallest frequency shift was −3.65 Hz corresponding to 103 CFU/mL. For the specificity tests, non-Salmonella samples such as E. coli, Listeria, and Staphylococcus resulted in low cross-reactivity. For signal amplification, biotinylated antibodies reacted to Salmonella followed by streptavidin—100 nm AuNPs through biotin-avidin interaction. The frequency shifts of 103 CFU/mL showed −28.04 Hz, and consequently improved the limit of detection.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2022 |
---|---|
Erschienen: |
2022 |
Enthalten in: |
Zur Gesamtaufnahme - volume:22 |
---|---|
Enthalten in: |
Sensors (Basel, Switzerland) - 22(2022), 22 vom: 18. Nov. |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Min, Hyun Jung [VerfasserIn] |
---|
Links: |
---|
Themen: |
7440-57-5 |
---|
Anmerkungen: |
Date Completed 29.11.2022 Date Revised 08.03.2023 published: Electronic Citation Status MEDLINE |
---|
doi: |
10.3390/s22228928 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM349464774 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM349464774 | ||
003 | DE-627 | ||
005 | 20231226042703.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2022 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.3390/s22228928 |2 doi | |
028 | 5 | 2 | |a pubmed24n1164.xml |
035 | |a (DE-627)NLM349464774 | ||
035 | |a (NLM)36433525 | ||
035 | |a (PII)8928 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Min, Hyun Jung |e verfasserin |4 aut | |
245 | 1 | 0 | |a Detection of Salmonella Typhimurium with Gold Nanoparticles Using Quartz Crystal Microbalance Biosensor |
264 | 1 | |c 2022 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 29.11.2022 | ||
500 | |a Date Revised 08.03.2023 | ||
500 | |a published: Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Demonstration of the Salmonella Typhimurium detection system was shown utilizing a quartz crystal microbalance (QCM) biosensor and signal enhancement by gold nanoparticles. In this study, a benchtop system of a QCM biosensor was utilized for the detection of Salmonella Typhimurium. It was designed with a peristaltic pump system to achieve immobilization of antibodies, detection of Salmonella, and the addition of gold nanoparticles to the sensor. As a series of biochemical solutions were introduced to the surface, the proposed system was able to track the changes in the resonant frequency which were proportional to the variations of mass on the sensor. For antibody immobilization, polyclonal antibodies were immobilized via self-assembled monolayers to detect Salmonella O-antigen. Subsequently, Salmonella Typhimurium was detected by antibodies and the average frequency before and after detecting Salmonella was compared. The highest frequency shifts were −26.91 Hz for 109 CFU/mL while the smallest frequency shift was −3.65 Hz corresponding to 103 CFU/mL. For the specificity tests, non-Salmonella samples such as E. coli, Listeria, and Staphylococcus resulted in low cross-reactivity. For signal amplification, biotinylated antibodies reacted to Salmonella followed by streptavidin—100 nm AuNPs through biotin-avidin interaction. The frequency shifts of 103 CFU/mL showed −28.04 Hz, and consequently improved the limit of detection | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Salmonella Typhimurium | |
650 | 4 | |a frequency shifts | |
650 | 4 | |a gold nanoparticles | |
650 | 4 | |a quartz crystal microbalance | |
650 | 7 | |a Gold |2 NLM | |
650 | 7 | |a 7440-57-5 |2 NLM | |
700 | 1 | |a Mina, Hansel A |e verfasserin |4 aut | |
700 | 1 | |a Deering, Amanda J |e verfasserin |4 aut | |
700 | 1 | |a Robinson, J Paul |e verfasserin |4 aut | |
700 | 1 | |a Bae, Euiwon |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Sensors (Basel, Switzerland) |d 2007 |g 22(2022), 22 vom: 18. Nov. |w (DE-627)NLM187985170 |x 1424-8220 |7 nnns |
773 | 1 | 8 | |g volume:22 |g year:2022 |g number:22 |g day:18 |g month:11 |
856 | 4 | 0 | |u http://dx.doi.org/10.3390/s22228928 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 22 |j 2022 |e 22 |b 18 |c 11 |