Oropharyngeal obstruction and respiratory system compliance are linked to ventilatory control parameters in pediatric obstructive sleep apnea syndrome
© 2022. The Author(s)..
Instable ventilatory control is an endotypic trait of obstructive sleep apnea syndrome (OSAS). This study aimed to evaluate the relationships between the anatomical compromise of the upper (oro- and naso-pharynx) and lower airways and ventilatory control (measured by chemical loop gain) in otherwise healthy children suffering from moderate to severe OSAS (apnea hypopnea index ≥ 5/hour). The children underwent ear, nose and throat examination, measurement of impedance of the respiratory system that allowed characterizing peripheral lung mechanics using the extended Resistance-Inertance-Compliance model. Physiologically constrained analytical model based on tidal breathing analysis allowed for the computation of steady-state plant gain, steady-state controller gain (CG0) and steady-state loop gain (LG0). Medium-frequency components of the feedback control system were then deduced. Fifty children (median age 11.2 years) were enrolled. Oropharyngeal obstruction was associated with decreased CG0 (0.6 [0.2; 1.0] vs 1.5 [0.5; 6.6] L.s- 1.mmHg- 1, p = 0.038) and LG0 (0.4 [0.2; 1.1] vs 1.2 [0.4; 9.3], p = 0.027), while nasal obstruction did not modify ventilatory control parameters. In a multivariate analysis Medium-Frequency PG was negatively related to minute ventilation and respiratory system compliance. Both upper (tonsil hypertrophy) and lower (compliance of respiratory system) airways are linked to ventilatory control in children with moderate to severe OSAS.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2022 |
---|---|
Erschienen: |
2022 |
Enthalten in: |
Zur Gesamtaufnahme - volume:12 |
---|---|
Enthalten in: |
Scientific reports - 12(2022), 1 vom: 15. Okt., Seite 17340 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Bokov, Plamen [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 18.10.2022 Date Revised 09.01.2023 published: Electronic Citation Status MEDLINE |
---|
doi: |
10.1038/s41598-022-22236-7 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM347587747 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM347587747 | ||
003 | DE-627 | ||
005 | 20231226205415.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2022 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1038/s41598-022-22236-7 |2 doi | |
028 | 5 | 2 | |a pubmed24n1158.xml |
035 | |a (DE-627)NLM347587747 | ||
035 | |a (NLM)36243786 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Bokov, Plamen |e verfasserin |4 aut | |
245 | 1 | 0 | |a Oropharyngeal obstruction and respiratory system compliance are linked to ventilatory control parameters in pediatric obstructive sleep apnea syndrome |
264 | 1 | |c 2022 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 18.10.2022 | ||
500 | |a Date Revised 09.01.2023 | ||
500 | |a published: Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2022. The Author(s). | ||
520 | |a Instable ventilatory control is an endotypic trait of obstructive sleep apnea syndrome (OSAS). This study aimed to evaluate the relationships between the anatomical compromise of the upper (oro- and naso-pharynx) and lower airways and ventilatory control (measured by chemical loop gain) in otherwise healthy children suffering from moderate to severe OSAS (apnea hypopnea index ≥ 5/hour). The children underwent ear, nose and throat examination, measurement of impedance of the respiratory system that allowed characterizing peripheral lung mechanics using the extended Resistance-Inertance-Compliance model. Physiologically constrained analytical model based on tidal breathing analysis allowed for the computation of steady-state plant gain, steady-state controller gain (CG0) and steady-state loop gain (LG0). Medium-frequency components of the feedback control system were then deduced. Fifty children (median age 11.2 years) were enrolled. Oropharyngeal obstruction was associated with decreased CG0 (0.6 [0.2; 1.0] vs 1.5 [0.5; 6.6] L.s- 1.mmHg- 1, p = 0.038) and LG0 (0.4 [0.2; 1.1] vs 1.2 [0.4; 9.3], p = 0.027), while nasal obstruction did not modify ventilatory control parameters. In a multivariate analysis Medium-Frequency PG was negatively related to minute ventilation and respiratory system compliance. Both upper (tonsil hypertrophy) and lower (compliance of respiratory system) airways are linked to ventilatory control in children with moderate to severe OSAS | ||
650 | 4 | |a Journal Article | |
700 | 1 | |a Boujemla, Imene |e verfasserin |4 aut | |
700 | 1 | |a Matrot, Boris |e verfasserin |4 aut | |
700 | 1 | |a Spruyt, Karen |e verfasserin |4 aut | |
700 | 1 | |a Gallego, Jorge |e verfasserin |4 aut | |
700 | 1 | |a Delclaux, Christophe |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Scientific reports |d 2011 |g 12(2022), 1 vom: 15. Okt., Seite 17340 |w (DE-627)NLM215703936 |x 2045-2322 |7 nnns |
773 | 1 | 8 | |g volume:12 |g year:2022 |g number:1 |g day:15 |g month:10 |g pages:17340 |
856 | 4 | 0 | |u http://dx.doi.org/10.1038/s41598-022-22236-7 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 12 |j 2022 |e 1 |b 15 |c 10 |h 17340 |