Not T too! False elevations in high-sensitivity cardiac troponin T (hs-TnT) following specimen transport
Copyright © 2022 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved..
Though false elevations attributed to preanalytical specimen handling have been widely reported for Troponin I (TnI), Troponin T (TnT) has appeared more robust to falsely elevated Tn. We describe reproducible false elevations in high sensitivity TnT (hs-TnT) in specimens after courier transport in plasma separator tubes (PST) off-site for testing. Hs-TnT was measured under 5 different conditions: 1) at collection location (N = 24); 2) after transport upright in racks (N = 66); 3) after transport with no control over tube agitation (N = 69); 4) on transported aliquots (N = 84); or 5) immediately after transport with no control over tube agitation (N = 16), followed by keeping the specimen upright and re-measuring at 1hr, 2hr, 4hr, and 20-24hrs (N = 6). To assess the degree of discrepancy, plasma from the original PST was aliquotted, re-centrifuged, potential debris removed, and hs-TnT re-measured. 43% of PST specimens collected offsite and transported with no control over tube agitation had clinically significant false elevations of hs-TnT which subsequently decreased following aliquotting and re-centrifugation (median decrease = 9.9 ng/L). Onsite testing or transported aliquots demonstrated no discrepancy. After being kept upright, discrepant specimens were not different from re-centrifuged aliquots by 4hrs (p = 0.6141, repeated measures ANOVA with Dunn's multiple comparisons). Clinically significant false elevations of hs-TnT occurred in approximately 40% of separated PSTs that were transported in containers where specimens are transported with no control over tube agitation. This interference does not occur if plasma is aliquoted or if hs-TnT is tested at the collection site. In order to prevent these false elevations, and their potential patient impact on the diagnosis of acute myocardial infarction, specimens for hs-TnT measurement should be aliquoted at the collection location prior to transport.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:115 |
---|---|
Enthalten in: |
Clinical biochemistry - 115(2023) vom: 26. Mai, Seite 86-91 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Paul, Heather A [VerfasserIn] |
---|
Links: |
---|
Themen: |
(3–6): Preanalytical |
---|
Anmerkungen: |
Date Completed 11.04.2023 Date Revised 11.04.2023 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.clinbiochem.2022.08.008 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM345454219 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM345454219 | ||
003 | DE-627 | ||
005 | 20231226025105.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.clinbiochem.2022.08.008 |2 doi | |
028 | 5 | 2 | |a pubmed24n1151.xml |
035 | |a (DE-627)NLM345454219 | ||
035 | |a (NLM)36027942 | ||
035 | |a (PII)S0009-9120(22)00197-7 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Paul, Heather A |e verfasserin |4 aut | |
245 | 1 | 0 | |a Not T too! False elevations in high-sensitivity cardiac troponin T (hs-TnT) following specimen transport |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 11.04.2023 | ||
500 | |a Date Revised 11.04.2023 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2022 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved. | ||
520 | |a Though false elevations attributed to preanalytical specimen handling have been widely reported for Troponin I (TnI), Troponin T (TnT) has appeared more robust to falsely elevated Tn. We describe reproducible false elevations in high sensitivity TnT (hs-TnT) in specimens after courier transport in plasma separator tubes (PST) off-site for testing. Hs-TnT was measured under 5 different conditions: 1) at collection location (N = 24); 2) after transport upright in racks (N = 66); 3) after transport with no control over tube agitation (N = 69); 4) on transported aliquots (N = 84); or 5) immediately after transport with no control over tube agitation (N = 16), followed by keeping the specimen upright and re-measuring at 1hr, 2hr, 4hr, and 20-24hrs (N = 6). To assess the degree of discrepancy, plasma from the original PST was aliquotted, re-centrifuged, potential debris removed, and hs-TnT re-measured. 43% of PST specimens collected offsite and transported with no control over tube agitation had clinically significant false elevations of hs-TnT which subsequently decreased following aliquotting and re-centrifugation (median decrease = 9.9 ng/L). Onsite testing or transported aliquots demonstrated no discrepancy. After being kept upright, discrepant specimens were not different from re-centrifuged aliquots by 4hrs (p = 0.6141, repeated measures ANOVA with Dunn's multiple comparisons). Clinically significant false elevations of hs-TnT occurred in approximately 40% of separated PSTs that were transported in containers where specimens are transported with no control over tube agitation. This interference does not occur if plasma is aliquoted or if hs-TnT is tested at the collection site. In order to prevent these false elevations, and their potential patient impact on the diagnosis of acute myocardial infarction, specimens for hs-TnT measurement should be aliquoted at the collection location prior to transport | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a (3–6): Preanalytical | |
650 | 4 | |a Agitation | |
650 | 4 | |a False positive | |
650 | 4 | |a Specimen transport | |
650 | 4 | |a Troponin | |
650 | 7 | |a Troponin T |2 NLM | |
650 | 7 | |a Biomarkers |2 NLM | |
650 | 7 | |a Troponin I |2 NLM | |
700 | 1 | |a Chi, Qingli |e verfasserin |4 aut | |
700 | 1 | |a Gifford, Jessica L |e verfasserin |4 aut | |
700 | 1 | |a Seiden-Long, Isolde |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Clinical biochemistry |d 1970 |g 115(2023) vom: 26. Mai, Seite 86-91 |w (DE-627)NLM000001988 |x 1873-2933 |7 nnns |
773 | 1 | 8 | |g volume:115 |g year:2023 |g day:26 |g month:05 |g pages:86-91 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.clinbiochem.2022.08.008 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 115 |j 2023 |b 26 |c 05 |h 86-91 |