We aimed to identify a simple metric accounting for peri-procedural hemoglobin changes, independent of blood product transfusion strategies, and assess its correlation with outcomes in patients undergoing left ventricular assist device (LVAD) implantation We included consecutive patients undergoing LVAD implantation at a single center between 10/1/2008 and 6/1/2014. The anemia stress index (ASI), defined as the sum of number of packed red blood cells transfused and the hemoglobin changes after LVAD implantation, was calculated for each patient at 24 h, discharge, and 3 months after LVAD implantation. Our cohort included 166 patients (80.1% males, mean age 56.3 ± 15.6 years) followed up for a median of 12.3 months. Increases in ASI per unit were associated with a higher hazard for all-cause mortality and early RV failure. The associations between the ASI and all-cause mortality persisted after multivariable adjustment, irrespective of when it was calculated (adjusted HR of 1.11, 95% CI 1.03-1.20 per unit increase in ASI). Similarly, ASI at 24 h after implant was associated with early RV failure despite multivariable adjustment (OR 1.09, 95% CI 1.05-1.14). We present a novel metric, the ASI, that is correlated with an increased risk for all-cause mortality and early RV failure in LVAD recipients.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2022 |
---|---|
Erschienen: |
2022 |
Enthalten in: |
Zur Gesamtaufnahme - volume:11 |
---|---|
Enthalten in: |
Journal of clinical medicine - 11(2022), 15 vom: 03. Aug. |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Shore, Supriya [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Revised 15.08.2022 published: Electronic Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.3390/jcm11154517 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM344749266 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM344749266 | ||
003 | DE-627 | ||
005 | 20231226023510.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2022 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.3390/jcm11154517 |2 doi | |
028 | 5 | 2 | |a pubmed24n1149.xml |
035 | |a (DE-627)NLM344749266 | ||
035 | |a (NLM)35956132 | ||
035 | |a (PII)4517 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Shore, Supriya |e verfasserin |4 aut | |
245 | 1 | 4 | |a The Anemia Stress Index-Anemia, Transfusions, and Mortality in Patients with Continuous Flow Ventricular Assist Devices |
264 | 1 | |c 2022 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 15.08.2022 | ||
500 | |a published: Electronic | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a We aimed to identify a simple metric accounting for peri-procedural hemoglobin changes, independent of blood product transfusion strategies, and assess its correlation with outcomes in patients undergoing left ventricular assist device (LVAD) implantation We included consecutive patients undergoing LVAD implantation at a single center between 10/1/2008 and 6/1/2014. The anemia stress index (ASI), defined as the sum of number of packed red blood cells transfused and the hemoglobin changes after LVAD implantation, was calculated for each patient at 24 h, discharge, and 3 months after LVAD implantation. Our cohort included 166 patients (80.1% males, mean age 56.3 ± 15.6 years) followed up for a median of 12.3 months. Increases in ASI per unit were associated with a higher hazard for all-cause mortality and early RV failure. The associations between the ASI and all-cause mortality persisted after multivariable adjustment, irrespective of when it was calculated (adjusted HR of 1.11, 95% CI 1.03-1.20 per unit increase in ASI). Similarly, ASI at 24 h after implant was associated with early RV failure despite multivariable adjustment (OR 1.09, 95% CI 1.05-1.14). We present a novel metric, the ASI, that is correlated with an increased risk for all-cause mortality and early RV failure in LVAD recipients | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a left ventricular assist device | |
650 | 4 | |a outcomes | |
700 | 1 | |a Hanff, Thomas C |e verfasserin |4 aut | |
700 | 1 | |a Mazurek, Jeremy A |e verfasserin |4 aut | |
700 | 1 | |a Fox, Arieh |e verfasserin |4 aut | |
700 | 1 | |a Tanna, Monique S |e verfasserin |4 aut | |
700 | 1 | |a Grandin, Edward W |e verfasserin |4 aut | |
700 | 1 | |a Zhang, Robert |e verfasserin |4 aut | |
700 | 1 | |a Wald, Joyce |e verfasserin |4 aut | |
700 | 1 | |a Peters, Carli |e verfasserin |4 aut | |
700 | 1 | |a Acker, Michael A |e verfasserin |4 aut | |
700 | 1 | |a Atluri, Pavan |e verfasserin |4 aut | |
700 | 1 | |a Rame, J Eduardo |e verfasserin |4 aut | |
700 | 1 | |a Goldberg, Lee R |e verfasserin |4 aut | |
700 | 1 | |a Jessup, Mariell |e verfasserin |4 aut | |
700 | 1 | |a Margulies, Kenneth B |e verfasserin |4 aut | |
700 | 1 | |a Birati, Edo Y |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of clinical medicine |d 2012 |g 11(2022), 15 vom: 03. Aug. |w (DE-627)NLM230666310 |x 2077-0383 |7 nnns |
773 | 1 | 8 | |g volume:11 |g year:2022 |g number:15 |g day:03 |g month:08 |
856 | 4 | 0 | |u http://dx.doi.org/10.3390/jcm11154517 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 11 |j 2022 |e 15 |b 03 |c 08 |