Biomechanical Strength of Screw Versus Suture Button Fixation in the Latarjet Procedure : A Cadaver Study
We compared the strength of screw vs suture button fixation in the Latarjet procedure for shoulder dislocation through biomechanical testing in a cadaver model. Cadavers were assigned randomly to receive screw or suture button fixation (both groups, n=5). The anteroposterior radius of the glenoid was measured, and a bony defect was created on the anteroinferior rim of the glenoid, equal to 25% of the width of the anteroposterior radius of the glenoid surface. The coracoid process was transferred into the newly created bony defect of the glenoid and fixed with two 3.5-mm partially threaded cannulated screws or 2 surgical buttons. All samples underwent tensile testing in the anteroinferior direction. Statistical analysis was performed to compare mean forces at failure between groups (alpha=.05). The mean force at failure was higher in the screw group (295 N; range, 103-534 N) than in the suture button group (133 N; range, 74-270 N) (P=.045). We found no difference between groups in ability to withstand a force of 150 N, which is the reported mean daily force threshold borne by the shoulder (P=.52). Screw fixation withstood a higher failure load than suture button fixation, indicating that screw fixation is a biomechanically superior option in the Latarjet procedure. The fixation methods did not differ in their ability to withstand the mean force borne by the shoulder during activities of daily living; thus, suture button fixation should be considered as an option in the Latarjet procedure. [Orthopedics. 2022;45(6):e321-e325.].
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2022 |
---|---|
Erschienen: |
2022 |
Enthalten in: |
Zur Gesamtaufnahme - volume:45 |
---|---|
Enthalten in: |
Orthopedics - 45(2022), 6 vom: 27. Nov., Seite e321-e325 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Hakverdiyev, Yasin [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 29.11.2022 Date Revised 29.11.2022 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.3928/01477447-20220805-01 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM344668223 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM344668223 | ||
003 | DE-627 | ||
005 | 20231226023316.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2022 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.3928/01477447-20220805-01 |2 doi | |
028 | 5 | 2 | |a pubmed24n1148.xml |
035 | |a (DE-627)NLM344668223 | ||
035 | |a (NLM)35947455 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Hakverdiyev, Yasin |e verfasserin |4 aut | |
245 | 1 | 0 | |a Biomechanical Strength of Screw Versus Suture Button Fixation in the Latarjet Procedure |b A Cadaver Study |
264 | 1 | |c 2022 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 29.11.2022 | ||
500 | |a Date Revised 29.11.2022 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a We compared the strength of screw vs suture button fixation in the Latarjet procedure for shoulder dislocation through biomechanical testing in a cadaver model. Cadavers were assigned randomly to receive screw or suture button fixation (both groups, n=5). The anteroposterior radius of the glenoid was measured, and a bony defect was created on the anteroinferior rim of the glenoid, equal to 25% of the width of the anteroposterior radius of the glenoid surface. The coracoid process was transferred into the newly created bony defect of the glenoid and fixed with two 3.5-mm partially threaded cannulated screws or 2 surgical buttons. All samples underwent tensile testing in the anteroinferior direction. Statistical analysis was performed to compare mean forces at failure between groups (alpha=.05). The mean force at failure was higher in the screw group (295 N; range, 103-534 N) than in the suture button group (133 N; range, 74-270 N) (P=.045). We found no difference between groups in ability to withstand a force of 150 N, which is the reported mean daily force threshold borne by the shoulder (P=.52). Screw fixation withstood a higher failure load than suture button fixation, indicating that screw fixation is a biomechanically superior option in the Latarjet procedure. The fixation methods did not differ in their ability to withstand the mean force borne by the shoulder during activities of daily living; thus, suture button fixation should be considered as an option in the Latarjet procedure. [Orthopedics. 2022;45(6):e321-e325.] | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Randomized Controlled Trial | |
700 | 1 | |a McFarland, Edward G |e verfasserin |4 aut | |
700 | 1 | |a Kaymakoglu, Mehmet |e verfasserin |4 aut | |
700 | 1 | |a Ozdemir, Erdi |e verfasserin |4 aut | |
700 | 1 | |a Akpinar, Sercan |e verfasserin |4 aut | |
700 | 1 | |a Huri, Pinar |e verfasserin |4 aut | |
700 | 1 | |a Costouros, John G |e verfasserin |4 aut | |
700 | 1 | |a Huri, Gazi |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Orthopedics |d 1978 |g 45(2022), 6 vom: 27. Nov., Seite e321-e325 |w (DE-627)NLM000843628 |x 0147-7447 |7 nnns |
773 | 1 | 8 | |g volume:45 |g year:2022 |g number:6 |g day:27 |g month:11 |g pages:e321-e325 |
856 | 4 | 0 | |u http://dx.doi.org/10.3928/01477447-20220805-01 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 45 |j 2022 |e 6 |b 27 |c 11 |h e321-e325 |