Dual-Energy CT for the Detection of Portal Vein Thrombosis : Improved Diagnostic Performance Using Virtual Monoenergetic Reconstructions
Purpose: To investigate the diagnostic performance of noise-optimized virtual monoenergetic images (VMI+) in dual-energy CT (DECT) of portal vein thrombosis (PVT) compared to standard reconstructions. Method: This retrospective, single-center study included 107 patients (68 men; mean age, 60.1 ± 10.7 years) with malignant or cirrhotic liver disease and suspected PVT who had undergone contrast-enhanced portal-phase DECT of the abdomen. Linearly blended (M_0.6) and virtual monoenergetic images were calculated using both standard VMI and noise-optimized VMI+ algorithms in 20 keV increments from 40 to 100 keV. Quantitative measurements were performed in the portal vein for objective contrast-to-noise ratio (CNR) calculation. The image series showing the greatest CNR were further assessed for subjective image quality and diagnostic accuracy of PVT detection by two blinded radiologists. Results: PVT was present in 38 subjects. VMI+ reconstructions at 40 keV revealed the best objective image quality (CNR, 9.6 ± 4.3) compared to all other image reconstructions (p < 0.01). In the standard VMI series, CNR peaked at 60 keV (CNR, 4.7 ± 2.1). Qualitative image parameters showed the highest image quality rating scores for the 60 keV VMI+ series (median, 4) (p ≤ 0.03). The greatest diagnostic accuracy for the diagnosis of PVT was found for the 40 keV VMI+ series (sensitivity, 96%; specificity, 96%) compared to M_0.6 images (sensitivity, 87%; specificity, 92%), 60 keV VMI (sensitivity, 87%; specificity, 97%), and 60 keV VMI+ reconstructions (sensitivity, 92%; specificity, 97%) (p ≤ 0.01). Conclusions: Low-keV VMI+ reconstructions resulted in significantly improved diagnostic performance for the detection of PVT compared to other DECT reconstruction algorithms.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2022 |
---|---|
Erschienen: |
2022 |
Enthalten in: |
Zur Gesamtaufnahme - volume:12 |
---|---|
Enthalten in: |
Diagnostics (Basel, Switzerland) - 12(2022), 7 vom: 10. Juli |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Martin, Simon S [VerfasserIn] |
---|
Links: |
---|
Themen: |
Diagnostic imaging |
---|
Anmerkungen: |
Date Revised 08.03.2023 published: Electronic Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.3390/diagnostics12071682 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM344053768 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM344053768 | ||
003 | DE-627 | ||
005 | 20231226021856.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2022 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.3390/diagnostics12071682 |2 doi | |
028 | 5 | 2 | |a pubmed24n1146.xml |
035 | |a (DE-627)NLM344053768 | ||
035 | |a (NLM)35885585 | ||
035 | |a (PII)1682 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Martin, Simon S |e verfasserin |4 aut | |
245 | 1 | 0 | |a Dual-Energy CT for the Detection of Portal Vein Thrombosis |b Improved Diagnostic Performance Using Virtual Monoenergetic Reconstructions |
264 | 1 | |c 2022 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 08.03.2023 | ||
500 | |a published: Electronic | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a Purpose: To investigate the diagnostic performance of noise-optimized virtual monoenergetic images (VMI+) in dual-energy CT (DECT) of portal vein thrombosis (PVT) compared to standard reconstructions. Method: This retrospective, single-center study included 107 patients (68 men; mean age, 60.1 ± 10.7 years) with malignant or cirrhotic liver disease and suspected PVT who had undergone contrast-enhanced portal-phase DECT of the abdomen. Linearly blended (M_0.6) and virtual monoenergetic images were calculated using both standard VMI and noise-optimized VMI+ algorithms in 20 keV increments from 40 to 100 keV. Quantitative measurements were performed in the portal vein for objective contrast-to-noise ratio (CNR) calculation. The image series showing the greatest CNR were further assessed for subjective image quality and diagnostic accuracy of PVT detection by two blinded radiologists. Results: PVT was present in 38 subjects. VMI+ reconstructions at 40 keV revealed the best objective image quality (CNR, 9.6 ± 4.3) compared to all other image reconstructions (p < 0.01). In the standard VMI series, CNR peaked at 60 keV (CNR, 4.7 ± 2.1). Qualitative image parameters showed the highest image quality rating scores for the 60 keV VMI+ series (median, 4) (p ≤ 0.03). The greatest diagnostic accuracy for the diagnosis of PVT was found for the 40 keV VMI+ series (sensitivity, 96%; specificity, 96%) compared to M_0.6 images (sensitivity, 87%; specificity, 92%), 60 keV VMI (sensitivity, 87%; specificity, 97%), and 60 keV VMI+ reconstructions (sensitivity, 92%; specificity, 97%) (p ≤ 0.01). Conclusions: Low-keV VMI+ reconstructions resulted in significantly improved diagnostic performance for the detection of PVT compared to other DECT reconstruction algorithms | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a diagnostic imaging | |
650 | 4 | |a liver | |
650 | 4 | |a multidetector computed tomography | |
650 | 4 | |a portal vein | |
650 | 4 | |a thrombosis | |
700 | 1 | |a Kolaneci, Jetlir |e verfasserin |4 aut | |
700 | 1 | |a Czwikla, Rouben |e verfasserin |4 aut | |
700 | 1 | |a Booz, Christian |e verfasserin |4 aut | |
700 | 1 | |a Gruenewald, Leon D |e verfasserin |4 aut | |
700 | 1 | |a Albrecht, Moritz H |e verfasserin |4 aut | |
700 | 1 | |a Thompson, Zachary M |e verfasserin |4 aut | |
700 | 1 | |a Lenga, Lukas |e verfasserin |4 aut | |
700 | 1 | |a Yel, Ibrahim |e verfasserin |4 aut | |
700 | 1 | |a Vogl, Thomas J |e verfasserin |4 aut | |
700 | 1 | |a Wichmann, Julian L |e verfasserin |4 aut | |
700 | 1 | |a Koch, Vitali |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Diagnostics (Basel, Switzerland) |d 2011 |g 12(2022), 7 vom: 10. Juli |w (DE-627)NLM250111136 |x 2075-4418 |7 nnns |
773 | 1 | 8 | |g volume:12 |g year:2022 |g number:7 |g day:10 |g month:07 |
856 | 4 | 0 | |u http://dx.doi.org/10.3390/diagnostics12071682 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 12 |j 2022 |e 7 |b 10 |c 07 |