Assessment of Four Obturation Methods in Deciduous Teeth Using Digital Radiography : An In Vivo Study
Copyright © 2022; The Author(s)..
Aim and objective: This study was carried out to comparatively assess the efficiency of four methods of obturation viz Lentulo spiral, Navi tip syringe, Bi directional spiral, and Past inject carrier in deciduous teeth using vista scan.
Materials and methods: A total sample of 100 primary root canals [4 groups of 25 canals each] with 2/3rd of root length were selected and randomly allocated into four different obturating techniques, i.e., Group I: Lentulo spiral, Group II: Navi tip syringe, Group III: Bi directional spiral, and Group IV: Past inject carrier. The quality of obturation [Coll and sadrain, 1996] and presence or absence of voids were evaluated by using Vista scan. The recorded data was statistically analyzed.
Results: The highest mean rank value of optimally filled canals was obtained by Group IV [58.00] followed by Group I [50.00] with no significant difference. The highest mean rank value of under filled canals and over filled canals were obtained by Group III and Group II, respectively, and these results were statistically significant. All the four obturation techniques showed presence of voids with no significant difference.
Conclusion: Both Lentulo spiral and Past inject carrier were equally efficient in attaining an optimally filled homogenous obturation in deciduous teeth.
How to cite this article: Raju SS, Reddy RE, Rani TS, et al. Assessment of Four Obturation Methods in Deciduous Teeth Using Digital Radiography: An In Vivo Study. Int J Clin Pediatr Dent 2022;15(S-1):S52-S56.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2022 |
---|---|
Erschienen: |
2022 |
Enthalten in: |
Zur Gesamtaufnahme - volume:15 |
---|---|
Enthalten in: |
International journal of clinical pediatric dentistry - 15(2022), Suppl 1 vom: 15., Seite S52-S56 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Raju, Srikanth S [VerfasserIn] |
---|
Links: |
---|
Themen: |
Deciduous teeth |
---|
Anmerkungen: |
Date Revised 16.07.2022 published: Print Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.5005/jp-journals-10005-2132 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM341675326 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM341675326 | ||
003 | DE-627 | ||
005 | 20231226012323.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2022 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.5005/jp-journals-10005-2132 |2 doi | |
028 | 5 | 2 | |a pubmed24n1138.xml |
035 | |a (DE-627)NLM341675326 | ||
035 | |a (NLM)35645507 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Raju, Srikanth S |e verfasserin |4 aut | |
245 | 1 | 0 | |a Assessment of Four Obturation Methods in Deciduous Teeth Using Digital Radiography |b An In Vivo Study |
264 | 1 | |c 2022 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 16.07.2022 | ||
500 | |a published: Print | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a Copyright © 2022; The Author(s). | ||
520 | |a Aim and objective: This study was carried out to comparatively assess the efficiency of four methods of obturation viz Lentulo spiral, Navi tip syringe, Bi directional spiral, and Past inject carrier in deciduous teeth using vista scan | ||
520 | |a Materials and methods: A total sample of 100 primary root canals [4 groups of 25 canals each] with 2/3rd of root length were selected and randomly allocated into four different obturating techniques, i.e., Group I: Lentulo spiral, Group II: Navi tip syringe, Group III: Bi directional spiral, and Group IV: Past inject carrier. The quality of obturation [Coll and sadrain, 1996] and presence or absence of voids were evaluated by using Vista scan. The recorded data was statistically analyzed | ||
520 | |a Results: The highest mean rank value of optimally filled canals was obtained by Group IV [58.00] followed by Group I [50.00] with no significant difference. The highest mean rank value of under filled canals and over filled canals were obtained by Group III and Group II, respectively, and these results were statistically significant. All the four obturation techniques showed presence of voids with no significant difference | ||
520 | |a Conclusion: Both Lentulo spiral and Past inject carrier were equally efficient in attaining an optimally filled homogenous obturation in deciduous teeth | ||
520 | |a How to cite this article: Raju SS, Reddy RE, Rani TS, et al. Assessment of Four Obturation Methods in Deciduous Teeth Using Digital Radiography: An In Vivo Study. Int J Clin Pediatr Dent 2022;15(S-1):S52-S56 | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Deciduous teeth | |
650 | 4 | |a Obturation techniques | |
650 | 4 | |a Quality of obturation | |
650 | 4 | |a Vista scan | |
650 | 4 | |a Voids | |
700 | 1 | |a Reddy, Rajendra E |e verfasserin |4 aut | |
700 | 1 | |a Rani, Thabitha S |e verfasserin |4 aut | |
700 | 1 | |a Merum, Kiranmayi |e verfasserin |4 aut | |
700 | 1 | |a Mudusu, Srujana P |e verfasserin |4 aut | |
700 | 1 | |a Tulluru, Ajay M |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t International journal of clinical pediatric dentistry |d 2008 |g 15(2022), Suppl 1 vom: 15., Seite S52-S56 |w (DE-627)NLM241758025 |x 0974-7052 |7 nnns |
773 | 1 | 8 | |g volume:15 |g year:2022 |g number:Suppl 1 |g day:15 |g pages:S52-S56 |
856 | 4 | 0 | |u http://dx.doi.org/10.5005/jp-journals-10005-2132 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 15 |j 2022 |e Suppl 1 |b 15 |h S52-S56 |