High-sensitivity Troponin I and Ablation Effectiveness Quotient after Ablation Index-guided pulmonary vein isolation-markers of arrhythmia recurrence?
© 2022. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature..
BACKGROUND: There are conflicting data regarding the relationship between high-sensitivity cardiac Troponin I (Hs-cTnI) and the ablation effectiveness quotient (AEQ) with arrhythmia recurrence following atrial fibrillation (AF) ablation. Our goals were to evaluate the impact of the Ablation Index (AI) software on Hs-cTnI and AEQ levels and to assess whether these markers are predictors of arrhythmia recurrence.
METHODS: Prospective single-center study of 75 consecutive patients referred for paroxysmal AF ablation from October 2017 to January 2019. Procedural endpoints and 2-year outcomes were assessed and compared to those of 75 propensity score-matched patients submitted to non-AI-guided pulmonary vein isolation (PVI) [control group].
RESULTS: Compared to the control group, patients having AI-guided PVI had lower Hs-cTnI values (1580 [IQR 1180-2140] ng/L vs. 2600 [IQR 1840 - 3900], p < 0.001) and a lower AEQ (0.9 [IQR 0.6-1.2] ng/L/s vs. 1.4 [0.8-1.6] ng/L/s, p < 0.001). After a median follow-up of 26 (IQR 20-32) months, there was a significant reduction in arrhythmia recurrence in the AI group (15% vs. 31%, HR 0.67 [95% CI, 0.32-1.40], p = 0.02). However, neither Hs-cTnI nor AEQ was predictors of arrhythmia recurrence in AI-guided PVI.
CONCLUSIONS: The use of the AI software led to reduced levels of Hs-cTnI and lower AEQ in AF patients submitted to PVI. However, none of these markers predicted arrhythmia recurrence.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2022 |
---|---|
Erschienen: |
2022 |
Enthalten in: |
Zur Gesamtaufnahme - volume:65 |
---|---|
Enthalten in: |
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing - 65(2022), 1 vom: 25. Okt., Seite 115-121 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Sousa, Pedro A [VerfasserIn] |
---|
Links: |
---|
Themen: |
Ablation Effectiveness Quotient |
---|
Anmerkungen: |
Date Completed 12.10.2022 Date Revised 14.10.2022 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1007/s10840-022-01229-6 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM339981245 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM339981245 | ||
003 | DE-627 | ||
005 | 20231226004120.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2022 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1007/s10840-022-01229-6 |2 doi | |
028 | 5 | 2 | |a pubmed24n1133.xml |
035 | |a (DE-627)NLM339981245 | ||
035 | |a (NLM)35469051 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Sousa, Pedro A |e verfasserin |4 aut | |
245 | 1 | 0 | |a High-sensitivity Troponin I and Ablation Effectiveness Quotient after Ablation Index-guided pulmonary vein isolation-markers of arrhythmia recurrence? |
264 | 1 | |c 2022 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 12.10.2022 | ||
500 | |a Date Revised 14.10.2022 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2022. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature. | ||
520 | |a BACKGROUND: There are conflicting data regarding the relationship between high-sensitivity cardiac Troponin I (Hs-cTnI) and the ablation effectiveness quotient (AEQ) with arrhythmia recurrence following atrial fibrillation (AF) ablation. Our goals were to evaluate the impact of the Ablation Index (AI) software on Hs-cTnI and AEQ levels and to assess whether these markers are predictors of arrhythmia recurrence | ||
520 | |a METHODS: Prospective single-center study of 75 consecutive patients referred for paroxysmal AF ablation from October 2017 to January 2019. Procedural endpoints and 2-year outcomes were assessed and compared to those of 75 propensity score-matched patients submitted to non-AI-guided pulmonary vein isolation (PVI) [control group] | ||
520 | |a RESULTS: Compared to the control group, patients having AI-guided PVI had lower Hs-cTnI values (1580 [IQR 1180-2140] ng/L vs. 2600 [IQR 1840 - 3900], p < 0.001) and a lower AEQ (0.9 [IQR 0.6-1.2] ng/L/s vs. 1.4 [0.8-1.6] ng/L/s, p < 0.001). After a median follow-up of 26 (IQR 20-32) months, there was a significant reduction in arrhythmia recurrence in the AI group (15% vs. 31%, HR 0.67 [95% CI, 0.32-1.40], p = 0.02). However, neither Hs-cTnI nor AEQ was predictors of arrhythmia recurrence in AI-guided PVI | ||
520 | |a CONCLUSIONS: The use of the AI software led to reduced levels of Hs-cTnI and lower AEQ in AF patients submitted to PVI. However, none of these markers predicted arrhythmia recurrence | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Ablation Effectiveness Quotient | |
650 | 4 | |a Ablation Index | |
650 | 4 | |a Arrhythmia Recurrence | |
650 | 4 | |a Atrial Fibrillation | |
650 | 4 | |a High-Sensitivity Cardiac Troponin I | |
650 | 4 | |a Pulmonary Vein Isolation | |
650 | 7 | |a Biomarkers |2 NLM | |
650 | 7 | |a Troponin I |2 NLM | |
700 | 1 | |a Puga, Luís |e verfasserin |4 aut | |
700 | 1 | |a Barra, Sérgio |e verfasserin |4 aut | |
700 | 1 | |a Campos, Diana |e verfasserin |4 aut | |
700 | 1 | |a António, Natália |e verfasserin |4 aut | |
700 | 1 | |a Elvas, Luís |e verfasserin |4 aut | |
700 | 1 | |a Gonçalves, Lino |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing |d 1997 |g 65(2022), 1 vom: 25. Okt., Seite 115-121 |w (DE-627)NLM096482982 |x 1572-8595 |7 nnns |
773 | 1 | 8 | |g volume:65 |g year:2022 |g number:1 |g day:25 |g month:10 |g pages:115-121 |
856 | 4 | 0 | |u http://dx.doi.org/10.1007/s10840-022-01229-6 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 65 |j 2022 |e 1 |b 25 |c 10 |h 115-121 |