Should a metal post always be replaced before a new indirect -restoration?
Before realizing a new indirect restoration on an endodontically treated tooth, present restorations and possible posts need to be assessed. In the case of a metal post, the mismatch in flexural modulus between the dentine and the post might increase the risk of a vertical root fracture. Is it therefore prudent to replace such a metal post, before the fabrication of a new indirect restoration? Two scenarios might be considered to answer this question. First, would a glass fibre post result in a lower risk of failure? Two systematic reviews of the literature comparing glass fibre and metal posts for the short term were contradictory. Second, is the occurrence of a vertical root fracture associated with the presence of a post? Such association could not be established either. On the basis of the current literature, there does not appear to be evidence to support actively replacing a metal post.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2022 |
---|---|
Erschienen: |
2022 |
Enthalten in: |
Zur Gesamtaufnahme - volume:129 |
---|---|
Enthalten in: |
Nederlands tijdschrift voor tandheelkunde - 129(2022), 4 vom: 14. Apr., Seite 163-167 |
Sprache: |
Niederländisch |
---|
Weiterer Titel: |
Moet een metalen stift altijd worden vervangen voor plaatsing van een kroon? |
---|
Beteiligte Personen: |
de Kuijper, M C F M [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 15.04.2022 Date Revised 15.04.2022 published: Print Citation Status MEDLINE |
---|
doi: |
10.5177/ntvt.2022.04.21110 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM33949753X |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM33949753X | ||
003 | DE-627 | ||
005 | 20231226003029.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2022 xx |||||o 00| ||dut c | ||
024 | 7 | |a 10.5177/ntvt.2022.04.21110 |2 doi | |
028 | 5 | 2 | |a pubmed24n1131.xml |
035 | |a (DE-627)NLM33949753X | ||
035 | |a (NLM)35420273 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a dut | ||
100 | 1 | |a de Kuijper, M C F M |e verfasserin |4 aut | |
245 | 1 | 0 | |a Should a metal post always be replaced before a new indirect -restoration? |
246 | 3 | 3 | |a Moet een metalen stift altijd worden vervangen voor plaatsing van een kroon? |
264 | 1 | |c 2022 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 15.04.2022 | ||
500 | |a Date Revised 15.04.2022 | ||
500 | |a published: Print | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Before realizing a new indirect restoration on an endodontically treated tooth, present restorations and possible posts need to be assessed. In the case of a metal post, the mismatch in flexural modulus between the dentine and the post might increase the risk of a vertical root fracture. Is it therefore prudent to replace such a metal post, before the fabrication of a new indirect restoration? Two scenarios might be considered to answer this question. First, would a glass fibre post result in a lower risk of failure? Two systematic reviews of the literature comparing glass fibre and metal posts for the short term were contradictory. Second, is the occurrence of a vertical root fracture associated with the presence of a post? Such association could not be established either. On the basis of the current literature, there does not appear to be evidence to support actively replacing a metal post | ||
650 | 4 | |a Journal Article | |
650 | 7 | |a Composite Resins |2 NLM | |
700 | 1 | |a van der Meer, W J |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Nederlands tijdschrift voor tandheelkunde |d 1962 |g 129(2022), 4 vom: 14. Apr., Seite 163-167 |w (DE-627)NLM000456926 |x 0028-2200 |7 nnns |
773 | 1 | 8 | |g volume:129 |g year:2022 |g number:4 |g day:14 |g month:04 |g pages:163-167 |
856 | 4 | 0 | |u http://dx.doi.org/10.5177/ntvt.2022.04.21110 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 129 |j 2022 |e 4 |b 14 |c 04 |h 163-167 |