Inferior Vena Cava Diameter Measurement Provides Distinct and Complementary Information to Right Atrial Pressure in Acute Decompensated Heart Failure
Copyright © 2022 Elsevier Inc. All rights reserved..
BACKGROUND: Inferior vena cava (IVC) measurements correlate only modestly with right atrial pressure (RAP). Part of this inaccuracy is due to the high compliance of the venous system, where a large change in blood volume may result in only a small change in pressure. As such, the information provided by the IVC may be different rather than redundant.
METHODS AND RESULTS: We analyzed patients in the ESCAPE (Evaluation Study of Congestive Heart Failure and Pulmonary Artery Catheterization Effectiveness) trial who had both pulmonary artery catheter and IVC measurements at baseline (n = 108). There was only a modest correlation between baseline RAP and IVC diameter (r = 0.41; P < 0.001). Hemoconcentration, defined as an increase in hemoglobin levels between admission and discharge, was correlated with decrease in IVC diameter (r = 0.35; P = 0.02) but not with a decrease in RAP (r = 0.01; P = 0.95). When patients had both IVC and RAP measurements that were below the median, survival rates were superior to the rates of those who had only 1 measurement below the median, and when both rates were above the median, patients fared the worst (P = 0.002).
CONCLUSION: IVC and RAP have limited correlation with each another, and changes in intravascular volume appear to correlate better with IVC diameter rather than with RAP. Furthermore, complementary information is provided by pressure and volume assessments in acute decompensated heart failure.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2022 |
---|---|
Erschienen: |
2022 |
Enthalten in: |
Zur Gesamtaufnahme - volume:28 |
---|---|
Enthalten in: |
Journal of cardiac failure - 28(2022), 7 vom: 28. Juli, Seite 1217-1221 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Griffin, Matthew [VerfasserIn] |
---|
Links: |
---|
Themen: |
Acute heart failure |
---|
Anmerkungen: |
Date Completed 19.07.2022 Date Revised 19.08.2022 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.cardfail.2022.02.014 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM338317392 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM338317392 | ||
003 | DE-627 | ||
005 | 20231226000410.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231226s2022 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.cardfail.2022.02.014 |2 doi | |
028 | 5 | 2 | |a pubmed24n1127.xml |
035 | |a (DE-627)NLM338317392 | ||
035 | |a (NLM)35301109 | ||
035 | |a (PII)S1071-9164(22)00107-5 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Griffin, Matthew |e verfasserin |4 aut | |
245 | 1 | 0 | |a Inferior Vena Cava Diameter Measurement Provides Distinct and Complementary Information to Right Atrial Pressure in Acute Decompensated Heart Failure |
264 | 1 | |c 2022 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 19.07.2022 | ||
500 | |a Date Revised 19.08.2022 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2022 Elsevier Inc. All rights reserved. | ||
520 | |a BACKGROUND: Inferior vena cava (IVC) measurements correlate only modestly with right atrial pressure (RAP). Part of this inaccuracy is due to the high compliance of the venous system, where a large change in blood volume may result in only a small change in pressure. As such, the information provided by the IVC may be different rather than redundant | ||
520 | |a METHODS AND RESULTS: We analyzed patients in the ESCAPE (Evaluation Study of Congestive Heart Failure and Pulmonary Artery Catheterization Effectiveness) trial who had both pulmonary artery catheter and IVC measurements at baseline (n = 108). There was only a modest correlation between baseline RAP and IVC diameter (r = 0.41; P < 0.001). Hemoconcentration, defined as an increase in hemoglobin levels between admission and discharge, was correlated with decrease in IVC diameter (r = 0.35; P = 0.02) but not with a decrease in RAP (r = 0.01; P = 0.95). When patients had both IVC and RAP measurements that were below the median, survival rates were superior to the rates of those who had only 1 measurement below the median, and when both rates were above the median, patients fared the worst (P = 0.002) | ||
520 | |a CONCLUSION: IVC and RAP have limited correlation with each another, and changes in intravascular volume appear to correlate better with IVC diameter rather than with RAP. Furthermore, complementary information is provided by pressure and volume assessments in acute decompensated heart failure | ||
650 | 4 | |a Clinical Trial | |
650 | 4 | |a Journal Article | |
650 | 4 | |a Acute heart failure | |
650 | 4 | |a invasive hemodynamics | |
650 | 4 | |a volume overload | |
700 | 1 | |a Ivey-Miranda, Juan |e verfasserin |4 aut | |
700 | 1 | |a McCallum, Wendy |e verfasserin |4 aut | |
700 | 1 | |a Sarnak, Mark |e verfasserin |4 aut | |
700 | 1 | |a Eder, Maxwell |e verfasserin |4 aut | |
700 | 1 | |a Bellumkonda, Lavanya |e verfasserin |4 aut | |
700 | 1 | |a Maulion, Christopher |e verfasserin |4 aut | |
700 | 1 | |a Wilson, F Perry |e verfasserin |4 aut | |
700 | 1 | |a Rao, Veena S |e verfasserin |4 aut | |
700 | 1 | |a Testani, Jeffrey |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of cardiac failure |d 1995 |g 28(2022), 7 vom: 28. Juli, Seite 1217-1221 |w (DE-627)NLM087692775 |x 1532-8414 |7 nnns |
773 | 1 | 8 | |g volume:28 |g year:2022 |g number:7 |g day:28 |g month:07 |g pages:1217-1221 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.cardfail.2022.02.014 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 28 |j 2022 |e 7 |b 28 |c 07 |h 1217-1221 |