Clinical and analytical evaluation of the Abbott AdviseDx quantitative SARS-CoV-2 IgG assay and comparison with two other serological tests

Copyright © 2022 Elsevier B.V. All rights reserved..

INTRODUCTION: Serological testing is an important tool to assist with assessing the immune response to SARS-CoV-2 infections, the causative agent of COVID-19. A quantitative assay was recently developed by Abbott Laboratories to measures antibodies against the receptor binding domain of the spike protein. In addition to assessing disease prevalence, this assay is useful towards determining the scale and duration of the humoral response to infection and vaccination. Here we evaluated the clinical and analytical performance of the quantitative Abbott AdviseDx SARS-CoV-2 IgG II assay and characterized the longitudinal dynamics of the IgG response against SARS-CoV-2 in 402 infected individuals up to 322 days post-symptom onset.

METHODS: To assess test sensitivity, 1257 serum specimens derived from 402 patients positive for SARS-CoV-2 by RT-PCR were analyzed on the Abbott Alinity platform. To evaluate test specificity, 394 specimens were tested from patients who were symptomatic but PCR negative for SARS-CoV-2, as well as 305 archived pre-pandemic samples. To further characterize test performance metrics, we evaluated assay precision and linearity.

RESULTS: The Abbott AdviseDx SARS-CoV-2 IgG II assay exhibited diagnostic specificity of 99.02% using 305 pre - COVID-19 serum specimens and 98.73% using 394 PCR negative specimens. Using 1257 sequential serum samples collected from PCR-confirmed individuals, clinical test sensitivity of the assay was 39.7% at 3-7 days, 75.9% at 8-14 days, 95.6% at 15-21 days, and 98.7% at 4-5 weeks post-symptom onset. The assay is linear across the analytical measurement range claimed by the manufacturer (22-25,000 AU/mL) and exhibited good analytical precision. The median concentration of IgG increased steadily from <22 AU/mL at 3-7 days post-symptom onset, to a peak of 14,421 AU/mL at 6-7 weeks. Although antibody concentration started to decline at 8-9 weeks following symptom onset, all patients remained seropositive during the observation period. When the positivity rate of this assay was compared with the Abbott anti-NP IgG and EUROIMMUN anti-S1 IgG tests, clinical sensitivity of the Abbott AdviseDx SARS-CoV-2 IgG II assay was the highest at all time points with the exception of 4-5 weeks after symptom onset.

CONCLUSION: The Abbott AdviseDx SARS-CoV-2 IgG II assay offers high test specificity and sensitivity across a broad reportable range. We anticipate this assay will be a useful towards quantitatively assessing the humoral immune response to COVID-19 infection and vaccination.

Medienart:

E-Artikel

Erscheinungsjahr:

2022

Erschienen:

2022

Enthalten in:

Zur Gesamtaufnahme - volume:503

Enthalten in:

Journal of immunological methods - 503(2022) vom: 21. Apr., Seite 113243

Sprache:

Englisch

Beteiligte Personen:

Maine, Gabriel N [VerfasserIn]
Krishnan, Subhashree Mallika [VerfasserIn]
Walewski, Kelly [VerfasserIn]
Trueman, Jillian [VerfasserIn]
Sykes, Elizabeth [VerfasserIn]
Sun, Qian [VerfasserIn]

Links:

Volltext

Themen:

Abbott
Anti-RBD
Anti-spike
Antibodies, Viral
Coronavirus
Immunoglobulin G
Journal Article
SARS-CoV-2 IgG

Anmerkungen:

Date Completed 30.03.2022

Date Revised 01.04.2022

published: Print-Electronic

Citation Status MEDLINE

doi:

10.1016/j.jim.2022.113243

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

NLM337131449