Evaluation of the SafeHeal Colovac+ Anastomosis Protection Device : A Preclinical Study

BackgroundThe protective ostomy is the current standard of care to protect a low colorectal anastomosis from leakage, but exposes patients to complications requiring an alternative strategy. The Colovac+ is a vacuum-based intraluminal bypass device designed to shield the anastomosis from fecal content, preventing the clinical outcomes of anastomotic leakage. The objective of this study was to evaluate the preliminary efficacy, safety, and technical feasibility of the Colovac+ in a porcine model. Methods: Twelve pigs received a colorectal anastomosis with Colovac+ implantation. The device was left in situ for 10 days and then retrieved endoscopically. Six pigs were to be sacrificed immediately after device retrieval and the other 6 were to be sacrificed on day 38. Clinical, endoscopic, and histopathological examinations were performed to evaluate the following endpoints: prevention of contact between the anastomosis and fecal content, device migration, feasibility of the implantation and retrieval procedure, collateral damage to the colonic wall, colon healing after device retrieval, and systemic toxicity related to the device. Results: Eleven pigs completed the study. One pig died prematurely due to a surgical complication unrelated to the device (bladder damage with uroperitoneum). There was no evidence of contact between the anastomosis and fecal content, none of the pigs developed symptomatic anastomotic leakage, there were no significant device migrations, and there was no evidence of systemic toxicity. Colovac+ implantation was easily performed in all cases except 1 (due to an inappropriate lubricant). Colovac+ retrieval was achieved successfully in all cases. Postretrieval examinations on day 10 revealed ulcerations at the anchoring site in 4 cases indicating mechanical damage caused by the stent. However, in the recovery group, no ulcerations were observed on day 38, and the colonic wall had properly healed in all animals. Conclusions: The Colovac+ is a technically feasible, safe, and efficient device for the protection of a colorectal anastomosis in a porcine model. The device holds promise for clinical use and warrants further research.

Medienart:

E-Artikel

Erscheinungsjahr:

2022

Erschienen:

2022

Enthalten in:

Zur Gesamtaufnahme - volume:29

Enthalten in:

Surgical innovation - 29(2022), 3 vom: 22. Juni, Seite 390-397

Sprache:

Englisch

Beteiligte Personen:

De Hous, Nicolas [VerfasserIn]
Khosrovani, Charam [VerfasserIn]
Lefevre, Jérémie H [VerfasserIn]
D'Urso, Antonio [VerfasserIn]
Komen, Niels [VerfasserIn]

Links:

Volltext

Themen:

Anastomotic leakage
Colorectal surgery
Colovac
Intraluminal bypass device
Journal Article
Protective ostomy

Anmerkungen:

Date Completed 24.06.2022

Date Revised 24.06.2022

published: Print-Electronic

Citation Status MEDLINE

doi:

10.1177/15533506211051274

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

NLM336234392