Interpretation of paced ECGs by the wearable defibrillator : Pitfalls and solutions
© 2021. Springer Medizin Verlag GmbH, ein Teil von Springer Nature..
The wearable cardioverter defibrillator (WCD) can protect patients against sudden cardiac death during temporarily increased or unknown risk of ventricular arrhythmias or in the situation of implantable cardioverter-defibrillator (ICD) explantation due to infection. In unusual cases, misinterpretation of the ECG by the tachycardia detection and discrimination algorithm of the WCD can occur which can lead to inappropriate acoustic alerts or inappropriate WCD therapy. We explain the mechanisms of inappropriate WCD therapy in two cases from daily clinical practice together with potential strategies to avoid such events in this special group of patients.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:32 |
---|---|
Enthalten in: |
Herzschrittmachertherapie & Elektrophysiologie - 32(2021), 4 vom: 28. Dez., Seite 500-503 |
Sprache: |
Deutsch |
---|
Weiterer Titel: |
Interpretation von Schrittmacher-EKGs durch die tragbare Defibrillatorweste : Fallstricke und Lösungen |
---|
Beteiligte Personen: |
Zylla, Maura M [VerfasserIn] |
---|
Links: |
---|
Themen: |
Journal Article |
---|
Anmerkungen: |
Date Completed 07.12.2021 Date Revised 14.12.2021 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1007/s00399-021-00822-y |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM332516598 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM332516598 | ||
003 | DE-627 | ||
005 | 20231225215730.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||ger c | ||
024 | 7 | |a 10.1007/s00399-021-00822-y |2 doi | |
028 | 5 | 2 | |a pubmed24n1108.xml |
035 | |a (DE-627)NLM332516598 | ||
035 | |a (NLM)34713343 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a ger | ||
100 | 1 | |a Zylla, Maura M |e verfasserin |4 aut | |
245 | 1 | 0 | |a Interpretation of paced ECGs by the wearable defibrillator |b Pitfalls and solutions |
246 | 3 | 3 | |a Interpretation von Schrittmacher-EKGs durch die tragbare Defibrillatorweste : Fallstricke und Lösungen |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 07.12.2021 | ||
500 | |a Date Revised 14.12.2021 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2021. Springer Medizin Verlag GmbH, ein Teil von Springer Nature. | ||
520 | |a The wearable cardioverter defibrillator (WCD) can protect patients against sudden cardiac death during temporarily increased or unknown risk of ventricular arrhythmias or in the situation of implantable cardioverter-defibrillator (ICD) explantation due to infection. In unusual cases, misinterpretation of the ECG by the tachycardia detection and discrimination algorithm of the WCD can occur which can lead to inappropriate acoustic alerts or inappropriate WCD therapy. We explain the mechanisms of inappropriate WCD therapy in two cases from daily clinical practice together with potential strategies to avoid such events in this special group of patients | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Pacemaker | |
650 | 4 | |a Sudden cardiac death | |
650 | 4 | |a Ventricular tachycardia | |
650 | 4 | |a Wearable defibrillator | |
700 | 1 | |a Thomas, Dierk |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Herzschrittmachertherapie & Elektrophysiologie |d 1997 |g 32(2021), 4 vom: 28. Dez., Seite 500-503 |w (DE-627)NLM093694202 |x 1435-1544 |7 nnns |
773 | 1 | 8 | |g volume:32 |g year:2021 |g number:4 |g day:28 |g month:12 |g pages:500-503 |
856 | 4 | 0 | |u http://dx.doi.org/10.1007/s00399-021-00822-y |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 32 |j 2021 |e 4 |b 28 |c 12 |h 500-503 |